PubMed Health⌕ Search

Biomedical subjects

Y Shiferaw

Publications and source records attributed to Y Shiferaw.

8 recordsLinked to original sources

Localization of a polymer in random media: relation to the localization of a quantum particle.

In this paper we consider in detail the connection between the problem of a polymer in a random medium and that of a quantum particle in a random potential. We are interested in a system of finite volume where the polymer is known to be localized inside a low minimum of the potential. We show how the end-to-end distance of a polymer that is free to move can be obtained from the density of states of the quantum particle using extreme value statistics. We give a physical interpretation to the recently discovered one-step replica-symmetry-breaking solution for the polymer [Phys. Rev. E 61, 1729 (2000)] in terms of the statistics of localized tail states. Numerical solutions of the variational equations for chains of different length are performed and compared with quenched averages computed directly by using the eigenfunctions and eigenenergies of the Schrödinger equation for a particle in a one-dimensional random potential. The quantities investigated are the radius of gyration of a free Gaussian chain, its mean square distance from the origin and the end-to-end distance of a tethered chain. The probability distribution for the position of the chain is also investigated. The glassiness of the system is explained and is estimated from the variance of the measured quantities.

Journal Article↗

Technical solution for an interactive functional MR imaging examination: application to a physiologic interview and the study of cerebral physiology.

Studies with functional magnetic resonance (MR) imaging produce large unprocessed raw data sets in minutes. The analysis usually requires transferring of the data to an off-line workstation, and this process frequently occurs after the subject has left the MR unit. The authors describe a hardware configuration and processing software that captures whole-brain raw data files as they are being produced from the MR unit. It then performs the reconstruction, registration, and statistical analysis, and displays the results in seconds after completion of the MR image acquisition.

Brain↗

Application of a 3D volume 19F MR imaging protocol for mapping oxygen tension (pO2) in perfluorocarbons at low field.

A limited flip angle gradient-echo 3D volume acquisition imaging protocol for mapping partial pressure of oxygen (pO2) in perfluorocarbon compounds (PFCs) at low field (0.14 T) is presented. The PO2 measurement method is based on the paramagnetic effect of dissolved molecular oxygen (O2) which reduces the PFC 19F T1. Specific objectives related to imaging of PFCs through use of the protocol include improved image signal-to-noise characteristics and elimination of 19F chemical shift artifacts. A parametric Wiener deconvolution filtering algorithm is used for suppression of 19F chemical shift artifacts. Application of the protocol is illustrated in a series of calculated PO2 maps of a gas equilibrated, multi-chamber phantom containing perfluorotributylamine (FC-43). The utility of the protocol is demonstrated in vivo through images of a commercially available perfluorocarbon based blood substitute emulsion containing FC-43 sequestered in the liver and spleen of a rat.

Algorithms↗

In vivo PO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low field.

Quantitative pO2 imaging in vivo has been evaluated utilizing F-19 NMR in the porcine model at 0.14 T for the lungs, liver, and spleen following i.p. administration of the commercial perfluorotributylamine (FC-43)-based perfluorocarbon (PFC) emulsion, Oxypherol-ET. Calculated T1 maps obtained from a two spin-echo saturation recovery/inversion recovery (SR/IR) pulse protocol are converted into quantitative pO2 images through a temperature-dependent calibration curve relating longitudinal relaxation rate (1/T1) to pO2. The uncertainty in pO2 for a T1 measurement error of +/- 5% as encountered in establishing the calibration curves ranges from +/- 10 torr (+/- 40%) at 25 torr to +/- 16 torr (+/- 11%) at 150 torr for FC-43 (37 degrees C). However, additional uncertainties in T1 dependent upon the signal-to-noise ratio may be introduced through the SR/IR calculated T1 pulse protocol, which might severely degrade the pO2 accuracy. Correlation of the organ image calculated pO2 with directly measured pO2 in airway or blood pools in six pigs indicate that the PFC resident in lung is in near equilibrium with arterialized blood and not with airway pO2, suggesting a location distal to the alveolar epithelium. For the liver, the strongest correlation implying equilibrium was evident for venous blood (hepatic vein). For the spleen, arterial blood pO2 (aorta) was an unreliable predictor of pO2 for PFC resident in splenic tissue. The results have demonstrated the utility and defined the limiting aspects quantitative pO2 imaging in vivo using F-19 MRI of sequestered PFC materials.

Animals↗

Quantitative pO2 imaging in vivo with perfluorocarbon F-19 NMR: tracking oxygen from the airway through the blood to organ tissues.

The physiological redistribution of perfluorocarbon (PFC) compounds to liver, spleen, bone marrow, and lung after intravenous (i.v.) or intraperitoneal (IP) administration of PFC emulsions affords the unique opportunity for non-invasive monitoring of oxygenation status of these organs and tissues utilizing fluorine (F-19) nuclear magnetic resonance (NMR) imaging techniques. PFCs also may be introduced directly into the pulmonary airways by procedures such as liquid ventilation, intratracheal instillation, or aerosol inhalation. Considerations of importance when establishing methodology for accurate quantitation of oxygen partial pressure (pO2) in vivo using F-19 NMR include: 1.) error analysis of the calibration curves which relate pO2 to the measured PFC F-19 relaxation rate, 2.) optimization of the NMR pulse sequence for efficient oxygen sensitive data acquisition and, 3.) fluorine signal independence from emulsion aqueous phase bioconstituents. The porcine model was investigated at 0.14T following i.v. or IP administration of the PFC emulsion containing perfluorotributylamine (FC-43) to demonstrate the capability for tracking oxygen with F-19 NMR from the lung through the blood to selected organ tissues. Quantitative pO2 projection images and isobaric contour graphs were derived for the liver, spleen, and lungs as a function of inspired oxygen. Blood pO2 levels in aorta, pulmonary artery, and hepatic vein were monitored simultaneously with NMR imaging for correlative analysis.

Animals↗

Perfluorocarbon distribution to liver, lung and spleen of emulsions of perfluorotributylamine (FTBA) in pigs and rats and perfluorooctyl bromide (PFOB) in rats and dogs by 19F NMR spectroscopy.

Perfluorocarbon emulsion (FCE) particles are reported to be taken up by the reticuloendothelial system (RES) and ultimately eliminated by the lung. This distribution provides an opportunity to measure oxygen partial pressure in vivo with fluorine-19 magnetic resonance imaging (19F MRI). Since the MR image signal-to-noise ratio is directly proportional to the fluorine concentration in the tissue, a greater concentration of perfluorocarbon (PFC) in the tissue will result in a greater confidence in the oxygen image and reduce measurement time. It was postulated that the biodistribution of PFC administered in emulsion form may depend on species RES or FCE composition. The distribution of an emulsion (Oxypherol-E.T.) containing perfluorotributylamine (FTBA) 5 days after administration to pigs (11 g FTBA/kg body weight i.p.) and rats (19 g FTBA/kg i.p.) and an emulsion (Oxygent) containing perfluorooctyl bromide (PFOB) 7 days after administration to dogs (11 g PFOB/kg i.v.) and 5 days after administrations to rats (19 g PFOB/kg i.p.) was analyzed by F-19 NMR spectroscopy of tissue samples. PFC concentrations in spleen are 2 to 3 times those in liver. This pattern appears to be independent of PFC emulsion or species. In contrast, lung PFC content was less than that in the liver and showed a dependence upon both species and PFC emulsion.

Animals↗

Evaluation of the influence of the aqueous phase bioconstituent environment on the F-19 T1 of perfluorocarbon blood substitute emulsions.

Oxygen-sensitive F-19 magnetic resonance imaging of perfluorocarbon compounds requires that fluorocarbon T1 changes correlate with the local PO2 and not with the composition of the surrounding aqueous phase. The influence of various bioconstituents and paramagnetic ions within the aqueous phase on the F-19 fluorocarbon phase T1 for PFC emulsions was evaluated at 0.14 and 0.66 T. T1 was measured for FC-43, perflubron, and a fluorinated surfactant. Controlled variables introduced in the aqueous phase included annex solution constituents, blood, pH changes, and Gd-DTPA. For a constant PO2, the F-19 T1s were independent of the emulsion constituents, blood concentration, and pH. For FC-43 and perflubron, F-19 T1 was independent of the Gd-DTPA concentration, while the aqueous phase T1 decreased by more than an order of magnitude. XMO-10 (smallest emulsion particle size) showed a slight decrease in F-19 T1 with increasing Gd-DTPA concentration at 0.66 T.

Animals↗