Cardiotoxicity after accidental herb-induced aconite poisoning.

Aconitine and its related alkaloids are known cardiotoxins with no therapeutic role in modern western medicine. The rootstocks of Aconitum plants, which contain aconite alkaloids, have been common components of Chinese herbal recipes. We have documented life-threatening intoxication in 17 Chinese subjects after accidental herb-induced aconite poisoning. All patients developed symptoms of aconite toxicity within 2 h of herb ingestion. Most developed tachyarrhythmias, including ventricular tachycardia and fibrillation from which 2 patients died. Toxicological evaluation revealed that aconites from the Aconitum rootstocks were the only plausible casual factor for intoxication. These cases point to the need for strict surveillance of herbal substances with low safety margins.

Accidents

Percutaneous transluminal coronary angioplasty in a patient with paroxysmal nocturnal hemoglobinuria.

Paroxysmal nocturnal hemoglobinuria (PHN) is an acquired chronic hemolytic anemia associated with an unusual susceptibility to hemolytic crisis, infection, and venous thrombosis which would be aggravated by a number of factors including surgery. We report a case of PHN undergoing percutaneous transluminal coronary angioplasty and discuss the corresponding perioperative management.

Adult

Successful sequential radiofrequency catheter ablation of anatomically discrete antegrade and retrograde accessory pathway conduction in the Wolff-Parkinson-White syndrome.

Histopathologically, accessory atrioventricular (AV) pathways comprise tiny strands of working myocardium that traverse the AV groove and link between the atrial and ventricular myocardium. Antegrade and retrograde conduction in bidirectional accessory pathways have generally been considered to occur along the same fibers. This report details the successful catheter ablation of a left free wall accessory pathway with radiofrequency energy. Antegrade and retrograde conduction of the pathway were abolished sequentially by separate episodes of energy delivered at anatomically discrete though closely adjacent sites along the mitral annulus. This finding raises the interesting possibility of anatomic "compartmentalization" of antegrade and retrograde conduction along an accessory pathway.

Adult

Ventricular rate-adaptive pacing in the elderly.

The role of ventricular rate-adaptive pacing (VVIR) in the elderly was investigated in 12 patients with a mean age of 85 +/- 2 years (range 75-95 years) with implanted activity-initiated VVIR pacemakers. Although four patients had significant extracardiac diseases, all were capable of independent walking and self care. The pacing rate achieved during structured daily activities (walking, climbing stairs, washing, bed-making and scrubbing floors) were compared with those achieved by 10 age-matched healthy subjects. Apart from the more strenuous activities (ascending stairs and floor-scrubbing), the pacing rates achieved by the patients were comparable to those of the healthy subjects and occurred within an appropriate time. In a 4-weekly randomized, double-blind crossover protocol in the VVI and VVIR pacing modes, all patients underwent assessments in a 12-min walking distance test, a 24 h non-invasive ambulatory blood pressure recording and a symptomatic documentation. During VVIR pacing, the 12-min walking distance was significantly improved compared to VVI pacing (556 +/- 52 vs. 545 +/- 55 m, P less than 0.05). There was no difference between the recorded blood pressure and symptom scores between the two pacing modes, although most patients preferred VVIR pacing (P less than 0.05). It is concluded that VVIR pacing in this elderly population can improve exercise capacity, and the patients' preference for the VVIR mode was documented despite the absence of a measurable difference in symptomatology.

Aged

The use of implantable sensors for the control of pacemaker mediated tachycardias: a comparative evaluation between minute ventilation sensing and acceleration sensing dual chamber rate adaptive pacemakers.

The role of implantable sensors to control pacemaker mediated tachycardias was investigated in 16 patients with two different dual chamber rate adaptive (DDDR) pacemakers, which sensed eiter minute ventilation (DDDR-Meta, nine patients) or body acceleration (Relay, seven patients). Successive atrial sensed events beyond a programmable rate occurring in the absence of detection of exercise by the sensors were considered to represent retrograde conduction or atrial arrhythmias, and the pacemakers responded by either a mode shift from DDDR to ventricular rate adaptive (VVIR) pacing (DDDR-Meta) or by tracking at an interim rate, the so-called conditional ventricular tracking limit (CVTL, Relay). In the unipolar atrial sensing mode, myopotential sensing (MPI) and external chest wall stimulations (CWS) at 250 beats/min were induced to be preferentially sensed by the atrial channel to simulate the conditions of atrial arrhythmias. In the DDD mode, these maneuvers resulted in ventricular responses of 88 +/- 3 beats/min and 110 +/- 3 beats/min for MPI and CWS, respectively. The pacing rate was significantly reduced in the DDDR mode with the sensors correctly detecting and responding to the sensed abnormal atrial signals (68 +/- 5 beats/min during MPI and 71 +/- 5 beats/min during CWS, P less than 0.005 compared with the corresponding DDD rate). One patient with a Relay pacemaker developed spontaneous atrial flutter and the ventricular tracking responses were 140 and 85 beats/min in the DDD and DDDR pacing modes, respectively. Thus MPI and CWS are useful bedside testing methods to assess pacemaker response during atrial arrhythmias. The use of implantable sensors to judge the appropriateness of atrial rate is a new approach to the management of pacemaker mediated tachycardias.

Adult

Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers.

Although a long postventricular atrial refractory period (PVARP) may prevent the occurrence of pacemaker mediated tachycardias and inadvertent tracking of atrial arrhythmias in dual chamber (DDD) pacing, the maximum upper rate will necessarily be compromised. We tested the feasibility of using minute ventilation sensing in a dual chamber rate adaptive pacemaker (DDDR) to shorten the PVARP during exercise in 13 patients with bradycardias (resting PVARP = 463 +/- 29 msec) to avoid premature upper rate behavior. Graded treadmill exercise tests in the DDD and DDDR modes at this PVARP resulted in maximum ventricular rates of 98 +/- 8 and 142 +/- 3 beats/min, respectively (P < 0.0001), due to chronotropic incompetence and upper rate limitation in the DDD mode, both circumvened with the use of sensor. In order to stimulate atrial arrhythmias, chest wall stimulation was applied for 30 seconds at a rate of 250 beats/min at a mean unipolar atrial sensitivity of 0.82 mV. Irregular ventricular responses occurred in the DDD mode (the rates at a PVARP of 280 and 463 +/- 29 msec were, respectively 92 +/- 5 and 66 +/- 3 msec; P < 0.0001). In the DDDR mode at a PVARP of 463 +/- 29 msec, regular ventricular pacing at 53 +/- 2 beats/min occurred due to mode switching to VVIR mode in the presence of repetitive sensed atrial events within the PVARP. One patient developed spontaneous atrial fibrillation on follow-up, which was correctly identified by the pacemaker algorithm, resulting in mode switch from DDDR to regular VVIR pacing and preservation of rate response. In conclusion, sensor controlled PVARP allows a long PVARP to be used at rest without limiting the maximum rate during exercise. In addition, to offer protection against retrograde conduction, a long PVARP and mode switching also limit the rate during atrial arrhythmias and allow regular ventricular rate responses according to the physiological demands.

Aged

Initial clinical experience with a single pass VDDR pacing system.

Although ventricular rate adaptive pacing (VVIR) improves exercise capacity and cardiac output compared to constant rate ventricular pacing (VVI), this pacing mode does not provide benefit of atrioventricular (AV) synchrony. We evaluated the use of a custom-built VDDR pacing system using a single pass, ventricular lead, which detects endocavity P wave using a pair of diagonally arranged atrial bipolar (DAB) electrodes. In the VDDR mode, AV synchrony is enabled and the P wave rate is used in conjunction with an accelerometer based activity sensor for rate adaptive pacing. A VDDR pacemaker was implanted in three patients with complete AV block (mean age 63 +/- 1 year) and the mean implantation time was 29 minutes. Mean P wave amplitude was 2.4 mV (1.2-4.2 mV) at implantation and telemetered P wave amplitude was stable over a follow-up of 6 months. At a sensitivity of 0.2 mV, stable P wave sensing was observed during breathing maneuvers, arm swinging, myopotential induction, and Holter recording. Paired exercise tests performed in the VDDR and VVIR modes showed higher cardiac output at rest, during exercise, and in the recovery period in the VDDR pacing mode. Thus VDDR pacing using a single pass lead is superior to VVIR pacing by enabling P synchronous ventricular pacing without adding to the complexity of implantation.

Acceleration

Clinical experience with an activity sensing DDDR pacemaker using an accelerometer sensor.

The rate adaptive characteristics and pacemaker mediated tachycardia protection algorithm of an accelerometer based DDDR pacemaker were evaluated in 11 patients with bradycardia (seven atrioventricular block, four sick sinus syndrome). Rate adaptive programming was effected by collecting the acceleration level during a 3-minute moderate exercise ("tailoring" of sensor). In comparison with an externally attached piezoelectric sensor, the accelerometer sensor showed lower rate changes during external tapping of the pacemaker (16 +/- 3 vs 29 +/- 4 ppm, P less than 0.02) and applied direct pressure (1 +/- 1 vs 40 +/- 3 beats/min, P less than 0.001) on the pacemaker. At nominal setting, the accelerometer sensor showed improved rate stability and higher rate response to jogging and standing, although responses to other daily activities and treadmill exercise were similar. Apart from changing the rate responsive slope, rate response could be improved by repeat "tailoring" of the sensor at a lower exercise level, resulting in better overall rate response characteristics. The ability of the rate monitoring software to collect acceleration levels for an activity and profile the projected rate response at different rate responsive settings allowed programming to be effected with the minimum amount of exercise testing. The pacemaker also discriminated atrial tachyarrhythmias from normal sinus response using the sensor to judge the appropriateness of the atrial rate, which correctly identified and prevented rapid ventricular tracking in two patients during atrial flutter/fibrillation.

Adult

Bidirectional tachycardia induced by herbal aconite poisoning.

This report details the clinical, electrocardiographic, and electropharmacological characteristics of an unusual case of bidirectional tachycardia induced by aconites present in a Chinese herbal decoction consumed by a previously healthy subject. The tachycardia showed marked susceptibility to vagotonic maneuvers, cholinesterase inhibition, and adenosine triphosphate. The incessant nature of the tachycardia, rapid recurrence after transient suppression, and failure to respond to direct current cardioversion suggested an automatic tachycardia mechanism consistent with known data on the cellular electrophysiological mechanism of aconitine-mediated arrhythmogenesis. A fascicular or ventricular myocardial origin of the tachycardia with alternating activation patterns, or dual foci with alternate discharge, appeared most plausible. The rootstocks of aconitum plants have been commonly employed in traditional Chinese herbal recipes for "cardiotonic" actions and for relieving "rheumatism." Multiple pitfalls could occur during the processing of these herbs that might have predisposed to aconite poisoning. The need for strict control and surveillance of herbal substances with low margins of safety is highlighted.

Aconitum

Incessant automatic ventricular tachycardia complicating acute coxsackie B myocarditis.

A 13-year-old girl presented with incessant ventricular tachycardia complicating acute Coxsackie B3 myocarditis. Electrophysiologic assessment revealed that the tachycardia could not be terminated, overdrive suppressed or accelerated by programmed electrical stimulation, but was transiently slowed by intravenous adenosine triphosphate and had marked spontaneous and sympathoautonomic-mediated fluctuation in the tachycardia cycle length. These features were atypical of reentry and triggered automaticity and suggested that abnormal automaticity was the likely tachycardia mechanism. Intravenous amiodarone slowed the ventricular tachycardia, but the patient eventually succumbed from rapidly progressive left ventricular failure. Postmortem pathohistologic examination confirmed the diagnosis of acute myocarditis.

Adolescent

Bilateral coronary-artery-to-pulmonary-artery fistula coexistent with apical hypertrophic cardiomyopathy--a case report.

A sixty-four-year-old man presented with repolarization abnormalities on the electrocardiogram. Echocardiography and cardiac catheterization revealed that he had the rare combination of apical hypertrophic cardiomyopathy with bilateral coronary-artery-to-pulmonary-artery fistula. An exercise thallium scan was negative, suggesting that the marked electrocardiographic changes were most likely secondary to the apical myocardial hypertrophy, instead of to coronary-steal-induced ischemia.

Arterio-Arterial Fistula

Transvenous radiofrequency catheter ablation of atrioventricular accessory pathways.

Transvenous delivery of radiofrequency energy is an attractive new technique in nonsurgical treatment of cardiac arrhythmias. We used radiofrequency catheter ablation in two patients with tachycardias complicating the Wolff-Parkinson-White syndrome. The first patient was a 28-year-old male who had suffered cardiac arrest from rapid preexcited atrial fibrillation (shortest RR interval of 180 ms) due to a left anterolateral free wall accessory pathway. The accessory pathway was mapped by means of positioning a 7F quadripolar catheter with a 4 mm tip to obtain the shortest atrial to ventricular timing during preexcited sinus rhythm. Unmodulated radiofrequency energy (750 KHz) was applied unipolarly between the distal pole of the catheter against an indifferent plate at the back. Using an applied energy of 30W, this resulted in the disappearance of both anterograde and retrograde conduction. The second patient was a 26-year-old man with concealed left posterolateral pathway. This was ablated at the site which corresponded to the shortest ventriculatrial timing during sustained atrioventricular reciprocating tachycardia. There was no complication from this procedure and both patients were discharged on the fourth day after the procedure and returned to work soon afterwards. Radiofrequency ablation is a safe and effective means for the treatment of paroxysmal supraventricular tachycardias.

Adult

Electromechanical concordance in alternans during sustained tachycardias.

Electrical alternans and mechanical alternans are intriguing phenomena that have been reported to occur during tachycardias. Their precise pathophysiologic mechanism and in particular their interrelation have not been well defined. This report documents an unusual electromechanical concordance in alternans during sustained supraventricular tachycardia and ventricular tachycardia in two patients, raising interesting possibilities on the underlying mechanism of the concordant phenomena. The findings highlight the principle of excitation--contraction coupling of the heart.

Adult

Angiographic visualization of 'tumour vascularity' in atrial myxoma.

Nine patients with atrial myxoma in whom selective coronary arteriography had been performed were studied. The angiographic sign of 'tumour vascularity' was found to be present in three patients with highly vascularized atrial myxoma. The clinical significance of the angiographic sign is unknown although highly vascularized myxomata appear to have a greater propensity to bleeding into the tumour, resulting in an acute worsening of clinical symptoms. The angiographic sign of 'tumour vascularity' is not specific but useful to complement the diagnosis of an atrial myxoma. The indication for selective coronary arteriography in patients with atrial myxoma remains the detection of coronary artery disease, thus concomitant coronary artery bypass surgery could be planned preoperatively.

Aged