Model of a vascular C-arm for 3D augmented fluoroscopy in interventional radiology.

This paper deals with the modeling of a vascular C-arm to generate 3D augmented fluoroscopic images in an interventional radiology context. A methodology based on the use of a multi-image calibration is proposed to assess the physical behavior of the C-arm. From the knowledge of the main characteristics of the C-arm, realistic models of the acquisition geometry are proposed. Their accuracy was evaluated and experiments showed that the C-arm geometry can be predicted with a mean 2D reprojection error of 0.5 mm. The interest of 3D augmented fluoroscopy is also assessed on a clinical case.

Computer-Aided Design↗

Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment.

PURPOSE: To evaluate three-dimensional (3D) digital subtraction angiography (DSA) as a supplement to two-dimensional (2D) DSA in the endovascular treatment (EVT) of intracranial aneurysms. MATERIALS AND METHODS: In 22 ruptured aneurysms, neck visualization, aneurysm shape, and EVT feasibility were analyzed at 2D DSA (anteroposterior, lateral, and rotational views) and at maximum intensity projection (MIP) and surface shaded display (SSD) 3D DSA. The possibility of obtaining a working view for EVT at 3D DSA and the relevance of measurements in choosing the first coil also were assessed. RESULTS: Two-dimensional DSA images clearly depicted the aneurysm neck in four of 22 aneurysms; MIP images, in 10; and SSD images, in 21, but SSD led to overestimation of the neck size in one aneurysm. Aneurysm shape was precisely demonstrated in five of 22 aneurysms at 2D DSA, in eight at MIP, and in all cases at SSD. In two of 22 aneurysms, EVT seemed to be nonfeasible at 2D DSA; however, SSD demonstrated feasibility and EVT was successfully performed. In one aneurysm, only SSD demonstrated the extension of the neck to a parent vessel, which was proved at surgery. Working views for EVT were deduced from 3D DSA findings in 20 of 21 aneurysms. The choice of the first coil was correct in 19 of 21 aneurysms. CONCLUSION: Three-dimensional DSA is valuable for evaluating the potential for EVT, finding a working view, and performing accurate measurements.

Adult↗

3D angiography. Clinical interest. First applications in interventional neuroradiology.

3D angiography is a true technical revolution that allows improvement in the quality and safety of diagnostic and endovascular treatment procedures. 3D angiography images are obtained by reconstruction of a rotational angiography acquisition done on a C-arm (GE Medical Systems) spinning at 40 degrees per second. The carotid or vertebral selective injection of a total of 15 ml of non-ionic contrast media at 3 ml/sec over 5 seconds allows the selection of the "arterial phase". Four hundred sixty 3D angiographic studies were performed from December 1996 to September 1998 on 260 patients and have been analyzed in MIP (Maximum Intensity Projection) and SSD (Shaded Surface Display) views. The exploration of intracranial aneurysms is simplified and only requires, for each vascular axis, a biplane PA and Lateral run followed by a single rotational angiography run. The 3D angiography image is available on the workstation's screen (Advantage Workstation 3.1, GE Medical Systems) in less than 10 minutes after the acquisition of the rotational run. It therefore allows one to analyze, during the intervention, the aneurysm's angioarchitecture, in particular the neck, and select the best therapeutic technique. When endovascular treatment is the best indication, 3D angiography allows one to define the optimal angle of view and accurately select the microcoils dimensions. 3D angiography replaces the multiple oblique views that used to be required to analyze the complex aneurysms and therefore allows a reduction of the total contrast medium quantity, the patient X-ray dose and the length of the intervention time which is a safety factor. Also, in particular for complex cases, it brings additional elements complementing the results of standard 2D DSA and rotational angiograms. In the cervical vascular pathology, 3D angiography allows for a better assessment of the stenosis level and of dissection lesions. Our current research activities focus on the matching without stereotactic frame between 3D X-ray angiography and volumetric MR acquisition, which should allow us to improve the treatment of intracerebral arterio-venous malformations (AVMs).

Aortic Dissection↗

Three-dimensional coronary arteriography.

In this paper we present a new imaging technique for three-dimensional (3-D) X-ray coronary arteriography. The goal is to provide in near to real-time a 3-D representation of the coronary arterial tree, helpful to better understand its topology and locate the possible lesions. The 3-D reconstruction of the coronary arteries is obtained from a set of X-ray conic projections acquired during a rotation of the imaging chain around the patient. Images are taken before and after injection of contrast agent. A subset of mask and opacified images is selected, corresponding to the same phase in the cardiac cycle. These images are subtracted and corrected for geometric distortion. The reconstruction is performed by using a two-step non-parametric detection/estimation method. Due to heart motion and propagation of the contrast agent, the number of available projections is very small. Typically 4 or 6 projections are available if the opacification is stable during 2 or 3 cardiac cycles and when using a biplane acquisition system. High resolution 512(3) reconstructions of the coronary arteries from a cadaver heart are presented, with a voxel size of 0.4 mm. The 3-D reconstruction provides a good 3-D representation of the global structure, even with a number of projections as small as 4.

Computer Graphics↗

In vivo evaluation of a new system for 3D computerized angiography.

A new system has been designed and built to validate the concept of 3D computerized angiography (CA). This system can acquire a set of 2D digital subtracted angiography images while rotating around a patient and then, using these images, reconstruct a 3D representation of the opacified vasculature. The design principles and main characteristics of the system are described, with special attention paid to data processing aspects. An initial in vivo evaluation of this system performed on anaesthetized animals and human volunteers is presented. The influence on the quality of the 3D reconstruction of different factors such as volume resolution, estimation method, source trajectory and number of projections is discussed.

Angiography↗

Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction.

Reconstructing a three-dimensional (3D) object from a set of its two-dimensional (2D) X-ray projections requires that the source position and image plane orientation in 3D space be obtained with high accuracy. We present a method for estimating the geometrical parameters of an X-ray imaging chain, based on the minimization of the reprojection mean quadratic error measured on reference points of a calibration phantom. This error is explicitly calculated with respect to the geometrical parameters of the conic projection, and a conjugate gradient technique is used for its minimization. By comparison to the classical unconstrained method, better results were obtained in simulation with our method, specially when only a few reference points are available. This method may be adapted to different X-ray systems and may also be extended to the estimation of the geometrical parameters of the imaging chain trajectory in the case of dynamic acquisitions.

Calibration↗

Image quality study in 3D X-ray angiography: a first approach using the experimental design strategy.

The visual detection of fine structures and the accuracy of the quantitation of geometric and densitometric features, are closely related to the quality of the images available in two-dimensional (2D) and three-dimensional (3D) X-ray angiography. In this context, we propose to analyze all the parameters influencing this accuracy using an experimental design strategy. Preliminary tests of this procedure, applied to 2D and 3D angiographic data obtained from a dedicated phantom, yield encouraging results. We show that the detection of small arteries in a 3D angiogram is more sensitive to the number of projections than to the X-ray dose.

Angiography, Digital Subtraction↗