PubMed Health⌕ Search

Biomedical subjects

Y Vander Heyden

Publications and source records attributed to Y Vander Heyden.

At least 37 records · Page 2Linked to original sources

Prediction of total green tea antioxidant capacity from chromatograms by multivariate modeling.

In this paper, a fast strategy for determining the total antioxidant capacity of Chinese green tea extracts is developed. This strategy includes the use of experimental techniques, such as fast high-performance liquid chromatography (HPLC) on monolithic columns and a spectrophotometric approach to determine the total antioxidant capacity of the extracts. To extract the chemically relevant information from the obtained data, chemometrical approaches are used. Among them there are correlation optimized warping (COW) to align the chromatograms, robust principal component analysis (robust PCA) to detect outliers, and partial least squares (PLS) and uninformative variable elimination partial least squares (UVE-PLS) to construct a reliable multivariate regression model to predict the total antioxidant capacity from the fast chromatograms.

Antioxidants↗

Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals part II: peak model and deconvolution algorithms.

Several interlinked algorithms for peak deconvolution by non-linear regression are presented. These procedures, together with the peak detection methods outlined in Part I, have allowed the implementation of an automatic method able to process multi-overlapped signals, requiring little user interaction. A criterion based on the evaluation of the multivariate selectivity of the chromatographic signal is used to auto-select the most efficient deconvolution procedure for each chromatographic situation. In this way, non-optimal local solutions are avoided in cases of high overlap, and short computation times are obtained in situations of high resolution. A new algorithm, fitting both the original signal and the second derivatives is proved to avoid local optima in intermediate coelution situations. This allows achieving the global optimum without the need of background knowledge by the user. A previously reported peak model, a Gaussian with a polynomial standard deviation whose complexity can be modulated to enhance the fitting quality, was applied. However, the original formulation was modified to account baseline outside the peak region. Also, the optimal model complexity was auto-selected via error propagation theory. The method is able to process simultaneously several related chromatograms. The software was tested with both simulated and experimental chromatograms obtained with monolithic silica columns.

Algorithms↗

Enantioselective capillary electrophoretic separation of tryptophane- and tyrosine-methylesters in a dual system with a tetra-oxadiaza-crown-ether derivative and a cyclodextrin.

Different dual selector systems containing a cyclodextrin derivative (methyl-beta-cyclodextrin and dimethyl-beta-cyclodextrin) and a new diaza-crown-ether derivative (N-[2-(1,4,10,13-tetraoxa-7,16-diazacyclooctadecan-7-yl)propanoyl]glycine) were studied in the enantioselective separation of tryptophan-methylester and tyrosine-methylester enantiomers. This paper deals with the systematic study of the effects of changing the composition of the background electrolyte on the resolution of the d- and l- forms using an experimental design approach. It was found that the dual systems allowed a better chiral separation of the amino acid derivatives. The experimental design approach also allowed improving the separation compared to the starting conditions (center point of the design), which were adopted from a previous study.

Algorithms↗

Inclusion complexation of diazepam with different cyclodextrins in formulations for parenteral use.

A parenteral formulation for the water-insoluble benzodiazepine diazepam was developed. Different cyclodextrins (CDs) suitable for parenteral injection: hydroxypropyl-beta-cyclodextrin (HP-beta-CD), hydroxy-propyl-gamma-cyclodextrin (HP-gamma-CD), sulfobutylether-7-beta-cyclodextrin (SBE-7-beta-CD) and maltosyl-beta-cyclodextrin (malt-beta-CD) were used as alternatives to cosolvents to increase solubility. The increase in solubility displayed a concentration dependency for the four CDs used. Diazepam's solubility is enhanced linearly as a function of each CD concentration. The highest improvements in solubility (dissolved concentration circa 3.5 mg/ml in 40% CD) were found by adding HP-beta-CD or SBE-7-beta-CD. The additional use of polyvinylpyrrolidone (PVP) did not further increase the solubility of diazepam with HP-beta-CD. A parenteral aqueous diazepam solution was prepared containing 10 mg diazepam/5 ml 30% HP-beta-CD or SBE-7-beta-CD solution. The preparations are in agreement with the requirements for parenteralia. Sterilisation by filtration is required since autoclaving degrades the active compound. The stability of the preparations, with and without pH adjustment to pH 5, was investigated during 18 months and during this period no noticeable degradation was observed.

Algorithms↗

Fast monolithic micellar liquid chromatography: an alternative drug permeability assessing method for high-throughput screening.

Several methods estimating the partitioning over biological membranes and thus the biological activity of potential oral drug molecules have been developed and are described in the literature. A previous study suggested that fast micellar liquid chromatography on a monolithic column could be one of them. For a set of diverse pharmaceuticals, retention by this fast chromatographic method was determined, besides other parameters also thought or established to describe oral permeability or absorption, e.g., from the Caco-2 permeability method. In view of a high-throughput determination of membrane permeability, a study was made of which information fast micellar liquid chromatography is providing and to what degree this system can replace other methods, i.e., deliver similar information. The retention with this fast method, which is mainly based on hydrophobic interactions, proved useful to sort substances into classes of Caco-2 and percent intestinal absorption.

Caco-2 Cells↗

The effect of preprocessing methods in reducing interfering variability from near-infrared measurements of creams.

This work is part of a study in which the possibility of NIR combined with some chemometrical methods is investigated as a suitable technique to classify clinical study samples of a cream. In this study, the influence of different preprocessing methods on the removal of spectral variations due to some variance sources has been investigated. The applied preprocessing methods are standard normal variate (SNV), detrend correction, offset correction, and first and second derivation. The investigated variance sources are different batches of ingredients, different samples of the same batch, different days and different positions of the sample cup in the sample drawer of the instrument. A nested ANOVA design has been applied in order to quantify the variances introduced by these variance sources. Since ANOVA is a univariate technique, the necessary variable (wavelength) selection has been performed by the Fisher criterion. The best results, i.e. largest reduction of interfering variability and clearest distinction between different clinical study samples, are obtained with the second derivative spectra.

Ointments↗

Multivariate adaptive regression splines (MARS) in chromatographic quantitative structure-retention relationship studies.

The multivariate adaptive regression splines (MARS) methodology was applied to build quantitative structure-retention relationships (QSRRs). The response (dependent variable) in the MARS models consisted of the logarithms of the extrapolated retention factors (log k(w)) of 83 structurally diverse drugs on a Unisphere PBD column, using isocratic elutions at pH 11.7. A set of 266 molecular descriptors was used as predictor (independent) variables in the MARS model building. The optimal MARS model uses 34 basis functions to describe the retention and has acceptable predictive properties for new objects. The molecular descriptors included in the model describe hydrophobicity, molecular size, complexity, shape and polarisability. Some additional MARS models were created using alternative strategies. These include models with log P as the single predictor and models obtained with only the three most important molecular descriptors. The use of classification and regression trees (CART) as feature selection technique for predictor variables used in the MARS model was also investigated. Further, it is also studied whether allowing quadratic terms instead of interaction terms might lead to better MARS models.

Chromatography, Liquid↗

Selection of reversed-phase liquid chromatographic columns with diverse selectivity towards the potential separation of impurities in drugs.

To select appropriate stationary phases from the continuously expanding supply of potentially suitable HPLC columns, the properties of 28 frequently applied stationary phases were determined by measuring several chromatographic parameters. From these results, based on chromatographic expertise, eight stationary phases with different properties and selectivities were selected. The aim of this study is to apply chemometric tools to evaluate the initially selected set of columns, i.e. a more systematic approach for making such a selection is examined. Starting from the information obtained on the 28 stationary phases, the re-evaluation was performed independently based on the chemometric techniques Pareto-optimality, principal component analysis (PCA), and Derringer's desirability functions. The aim was to select a set of efficient columns exhibiting large selectivity differences. The chemometrically selected stationary phases were divided in groups based on hydrophobicity, a critical retention-determining property in reversed-phase chromatography. This allowed to further reducing the selection to three columns. It is demonstrated that the selection by the chemometric approaches in general is fairly comparable with the initial selection.

Chromatography, High Pressure Liquid↗

Definition and system implementation of strategies for method development of chiral separations in normal- or reversed-phase liquid chromatography using polysaccharide-based stationary phases.

This paper proposes strategies in normal- and reversed-phase liquid chromatography (NP-HPLC or NPLC and RP-HPLC or RPLC), which were developed using three polysaccharide-based stationary phases. Those strategies are implemented in a knowledge-based system for the chiral separation of drug enantiomers. Each strategy includes a screening and an optimisation stage. The screening stage allows a fast evaluation of separation possibilities and enantioselectivity for many drugs in a short period of time, while the optimisation stage gives the opportunity to enhance, if needed, the initially obtained separation. Different examples demonstrate the effectiveness of the strategies for fast method development.

Chromatography, High Pressure Liquid↗

Comparison of the miniaturised techniques capillary electrochromatography and capillary liquid chromatography for the chiral separation of chlorthalidone.

The aim of this study was to compare the miniaturised techniques, capillary electrochromatography (CEC) and capillary liquid chromatography (CLC), for the chiral separation of chlorthalidone. In both cases, hydroxypropyl-beta-cyclodextrin was used as a chiral selector in the mobile phase, while an achiral stationary phase was used. Earlier, this separation was already optimised in CEC. Now, the separation was optimised in CLC. The influence of the organic modifier content and the cyclodextrin concentration on the separation was studied by means of a central composite design. Optimal separation conditions were determined, after response modelling, from the response surface contour plots. When these conditions were compared with those of the CEC optimisation, we can see the potential of using CLC as a chiral separation technique since less chiral selector was used, faster separations were obtained and better repeatability was observed in comparison with its electrical-driven counterpart.

Chlorthalidone↗

Determining orthogonal and similar chromatographic systems from the injection of mixtures in liquid chromatography-diode array detection and the interpretation of correlation coefficients color maps.

Generic orthogonal chromatographic systems might be helpful tools as potential starting points in the development of methods to separate impurities and the active substance in drugs with unknown impurity profiles. The orthogonality of 38 chromatographic systems was evaluated from weighted-average-linkage dendrograms and color maps, both based on the correlation coefficients between the retention factors on the different systems. On each chromatographic system, 68 drug substances were injected as mixtures of three or four components to increase the throughput. The (overlapping) peaks were identified and resolved with a peak purity algorithm, orthogonal projection approach (OPA). The visualization techniques applied allowed a simple evaluation of orthogonal and (groups of) similar systems.

Algorithms↗

Quantitative determination of p-aminosalicylic acid and its degradation product m-aminophenol in pellets by ion-pair high-performance liquid chromatography applying the monolithic Chromolith Speedrod RP-18e column.

An ion-pair high performance liquid chromatographic method was developed for the simultaneous determination of p-aminosalicylic acid (PAS) and its degradation product m-aminophenol (MAP) in a newly developed multiparticular drug delivery system. Owing to the concentration differences of PAS and MAP, acetanilide and sulfanilic acid were used as internal standards, respectively. The separation was performed on a Chromolith SpeedROD RP-18e column, a new packing material consisting of monolithic rods of highly porous silica. The mobile phase composition was of 20 mm phosphate buffer, 20 mm tetrabutylammonium hydrogen sulphate and 16% (v/v) methanol adjusted to pH 6.8, at a flow-rate of 1.0 mL/min, resulting in a run-time of about 6 min. Detection was by UV at 233 nm. The method was validated and proved to be useful for stability testing of the new dosage form. Separation efficiency was compared between the new packing material Chromolith SpeedROD RP-18e and the conventional reversed-phase cartridge LiChroCART 125-4 (5 microm). A robustness test was carried out on both columns and different separation parameters (retention, resolution, run time, temperature) were determined.

Aminophenols↗

Preparation and in-vitro release rate of fentanyl-cyclodextrin complexes for prolonged action in epidural analgesia.

Fentanyl was complexed with cyclodextrin derivatives with the intention to obtain parenteral solutions able to provide prolonged analgesia following epidural administration. Three cylodextrins (CDs) suitable for parenteral use were used: hydroxypropyl-beta-cyclodextrin (HP-beta-CD), sulfobutylether-beta-cyclodextrin (SBE-7-beta-CD), and maltosyl-beta-cyclodextrin (malt-beta-CD). Analysis of fentanyl was done with HPLC-UV. The inclusion capacity of HP-beta-CD was determined from phase-solubility diagrams at pH 6.5, 7.2 and 8.0, and those of SBE-7-beta-CD and of malt-beta-CD at pH 8.0. Solubility of fentanyl increased linearly (i) as a function of the CD concentration, and (ii) with decreasing pH. Complexation was highest with HP-beta-CD and malt-beta-CD, much higher than with SBE-7-beta-CD, with stability constants at pH 8.0 of 801, 729 and 1309 M(-1), respectively. The CD concentration was calculated to obtain a fentanyl-CD formulation, with the desired amount free fentanyl as loading dose in solution and the rest complexed with CD, as reservoir for prolonged action. A suitable membrane and a release-rate apparatus were selected for in-vitro release-rate studies. Best results were obtained with Spectrapor membranes and a home-made release-rate apparatus. Release rate was evaluated in static and dynamic conditions. For both modes, the release rate of fentanyl decreased as a function of CD concentration, due to complex formation of fentanyl, which suggests the possibility to provide prolonged pharmacodynamic effects in vivo.

2-Hydroxypropyl-beta-cyclodextrin↗

Analysis of erythromycin and benzoylperoxide in topical gels by liquid chromatography.

Gels containing a combination of erythromycin and benzoylperoxide are frequently used in the treatment of acne vulgaris. A method was developed to determine the content of both erythromycin and benzoylperoxide in these gels. Erythromycin was extracted from the gel in conditions where the oxidative power of benzoylperoxide was neutralised by addition of ascorbic acid and this extract was analysed on an Xterra RP(18) column, with a mobile phase containing acetonitrile-0.2 M K2HPO4-water (35:5:60, v/v/v). The detection wavelength was 215 nm. A second extraction procedure was developed for the analysis of benzoylperoxide. The extraction solution was analysed on a Hypersil C(18) BDS column and a mobile phase containing acetonitrile-water (58:42, v/v). Detection was performed at 254 nm. The flow rate was 1.0 ml/min in both methods. The selectivity, repeatability, linearity and recovery of both methods were examined. Special attention was given to determination of the recovery and the uncertainty on the recovery. This allowed evaluation of the bias of the extraction method. The method developed was used to examine the stability of a gel for topical use.

Administration, Topical↗

Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

Anti-Bacterial Agents↗

Fast separations on monolithic silica columns: method transfer, robustness and column ageing for some case studies.

Six separation methods, developed on conventional silica high performance liquid chromatography (HPLC) columns were transferred to monolithic silica columns of 5 and 10 cm length. The transferred methods include the separation of an alkylbenzene mixture, the separations of drugs from their impurities (nimesulide, tetracycline, phenoxymethylpenicillin and erythromycin) and the separation of a green tea extract. The transfer of the first three methods was successful while for the latter three it was not. Increasing the flow rate up to 9 ml/min (where possible) inversely decreased the analysis time of the successfully transferred methods to 48 s (alkylbenzene mixture) 1.8 min (nimesulide mixture) and 3 min (tetracycline mixture) while still reasonable well separated peaks were obtained. The robustness and repeatability of the transferred and accelerated separations was found to be acceptable. Despite the use of flow rates up to 9 ml/min and frequent mobile phase changes with pH values varying from 3.5 to 7, the column performance was found to be rather constant and the column ageing to be minimal.

Chromatography, High Pressure Liquid↗

Validation of an HPLC method on short columns to assay ketoconazole and formaldehyde in shampoo.

An HPLC method to determine simultaneously ketoconazole and formaldehyde in an anti-dandruff shampoo, originally developed on a long column, was transferred to two short columns with similar stationary phase properties, but with a length of at the most 30% of the initial one. Using the conventional column as reference, the fast HPLC methods on the short columns were validated. The validation characteristics consisted of selectivity, linearity range, precision (repeatability and time-different intermediate precision), bias and robustness. For the ketoconazole assay, linearity for peak area was found in the concentration range up to 0.20 mg/ml. For formaldehyde, two calibration ranges (0-10 x 10(-5) and 0-10 x 10(-4)%) were linear, both for peak area and height. The assays for both ketoconazole and formaldehyde in these ranges showed no bias and an acceptable precision, although the precision found with the short columns was slightly worse than with the long one. The robustness tests were performed applying a Plackett-Burman design. For the ketoconazole assay, 6 factors were examined in a 12 experiments design and for formaldehyde, 11 factors in 16 experiments. The methods were found to be robust. Despite the somewhat less good precision the transfer seems to be successful and the obtained assays on the short columns are applicable for fast routine analysis.

Antifungal Agents↗

Classification and regression tree analysis for molecular descriptor selection and retention prediction in chromatographic quantitative structure-retention relationship studies.

The use of the classification and regression tree (CART) methodology was studied in a quantitative structure-retention relationship (QSRR) context on a data set consisting of the retentions of 83 structurally diverse drugs on a Unisphere PBD column, using isocratic elutions at pH 11.7. The response (dependent variable) in the tree models consisted of the predicted rention factor (log kw) of the solutes, while a set of 266 molecular descriptors was used as explanatory variables in the tree building. Molecular descriptors related to the hydrophobicity (log P and Hy) and the size (TPC) of the molecules were selected out of these 266 descriptors in order to describe and predict retention. Besides the above mentioned, CART was also able to select hydrogen-bonding and molecular complexity descriptors. Since these variables are expected from QSRR knowledge, it demonstrates the potential of CART as a methodology to understand retention in chromatographic systems. The potential of CART to predict retention and thus occasionally to select an appropriate system for a given mixture was also evaluated. Reasonably good prediction, i.e. only 9% serious misclassification, was observed. Moreover, some of the misclassifications probably are inherent to the data set applied.

Chromatography↗