Fatal familial insomnia with an unusual prion protein deposition pattern: an autopsy report with an experimental transmission study.

We recently performed a post-mortem examination on a Japanese patient who had a prion protein gene mutation responsible for fatal familial insomnia (FFI). The patient initially developed cerebellar ataxia, but finally demonstrated insomnia, hyperkinetic delirium, autonomic signs and myoclonus in the late stage of the illness. Histological examination revealed marked neuronal loss in the thalamus and inferior olivary nucleus; however, prion protein (PrP) deposition was not proved in these lesions by immunohistochemistry. Instead, PrP deposition and spongiform change were both conspicuous within the cerebral cortex, whereas particular PrP deposition was also observed within the cerebellar cortex. The abnormal protease-resistant PrP (PrP(res)) molecules in the cerebral cortex of this case revealed PrP(res) type 2 pattern and were compatible with those of FFI cases, but the transmission study demonstrated that a pathogen in this case was different from that in a case with classical FFI. By inoculation with homogenate made from the cerebral cortex, the disease was transmitted to mice, and neuropathological features that were distinguishable from those previously reported were noted. These findings indicate the possibility that a discrete pathogen was involved in the disease in this case. We suggest that not only the genotype of the PrP gene and some other as yet unknown genetic factors, but also the variation in pathogen strains might be responsible for the varying clinical and pathological features of this disease.

Amyloid beta-Protein Precursor↗

Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist.

A bypass flow rate estimation and control system (BECS) for an implantable centrifugal blood pump (ICBP) has been developed in our institute. The estimated flow rate (EF) of the ICBP was derived from the electric power consumption, the rotating speed of a motor, and the blood viscosity presumed by the hematocrit and body temperature. The error in the EF was 0.5 +/- 0.4 L/min in in vivo experiments for 40 days. The rotating speed of the motor was controlled automatically every 200 ms to bring the EF in accord with the desired flow rate (DF). The reactivity and accuracy of the BECS were investigated in in vitro and in vivo experiments. The ICBP was operated by the BECS in a mock circuit in parallel with a pulsatile ventricular assist device (PVAD) to simulate left heart bypass. The reactivity was evaluated by changing the DF from 7 L/min to 5 L/min at an afterload of 160/97 mm Hg. To evaluate the accuracy of the BECS, the ICBP was driven under the aortic pressure of 110/85 mm Hg in the abdominal wall of an adult goat (70 kg). The DF was set at 5 L/min for 4 min for the goat in an awake condition. It took 13 s to change the flow rate in the in vitro experiment. The measured flow rate (MF) was maintained at 5.0 +/- 0.2 L/min by the BECS in vivo. In conclusion, the BECS has moderate reactivity and accuracy.

Abdominal Muscles↗

Intrathoracic and intraabdominal wall implantation of a centrifugal blood pump for circulatory assist.

An implantable centrifugal pump (ICP) 320 ml in volume and 830 g in weight has been developed for prolonged circulatory assist. The antithrombogenicity of the ICP is provided by a balancing hole in the center of the impeller. The watertightness and histocompatibility of the ICP are supported by its silicone ring seal and its casing of titanium and acrylic resin, respectively. The total efficiency of the ICP was 30% at a 5 L/min flow rate and a 100 mm Hg head. The heat generation, watertightness, and anatomical fitting of the ICP were assessed in an intrathoracic implantation in a goat (66 kg) and in an intraabdominal wall implantation in a goat (70 kg). Warfarin was given for anticoagulation in each experiment to keep the prothrombin time around 1.7 times that of the control. The temperatures of the pump surface, the pleura, and the room were measured every 3 h. Anatomical fitting was evaluated by pathological observation after the termination of the experiment. The ICP could run for 40 days in the chest cavity and for 11 days in the abdominal wall. The temperature of the motor remained about 1.8 degrees C higher than the reference in both experiments. The ICP was completely covered by a layer of smooth fibrous tissue. The moisture content of the seals remained normal. Although a small amount of atelectasis was found in the lingula, neither lung adhesion nor necrotic change of the chest wall was observed. The inflammation of the surrounding tissue including foreign body reaction and thermal burn was minimal. In conclusion, the ICP has satisfied in vivo testing of its watertightness, exothermicity, and anatomical fitting.

Abdominal Muscles↗

Prolonged nonpulsatile left heart bypass with reduced systemic pulse pressure causes morphological changes in the aortic wall.

We investigated the morphological changes in the aorta due to reduced systemic pulse pressure in prolonged nonpulsatile left heart bypass (LHB). Nineteen adult goats were divided into 3 groups, the nonpulsatile group in which nonpulsatile LHB was conducted, the pulsatile group in which pulsatile LHB was conducted, and the control group used as the normal control. The average aortic pulse pressures were 12, 47, and 37 mm Hg, respectively. The descending aorta was subjected to morphological examination. In the nonpulsatile group, the wall was significantly thinner, and the volume ratio of smooth muscle cells (SMCs) was much lower. In terms of the SMC type classification, the proportion of SMCs with low activity and low contractility was higher, and the cell density of the SMCs was increased compared to those in the other groups. These results indicate that prolonged nonpulsatile LHB causes morphological atrophic changes in the aorta.

Animals↗

Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization, and computational fluid dynamics: results in hemolysis tests.

There are few established engineering guidelines aimed at reducing hemolysis for the design of centrifugal blood pumps. In this study, a fluid dynamic approach was applied to investigate hemolysis in centrifugal pumps. Three different strategies were integrated to examine the relationship between hemolysis and flow patterns. Hemolytic performances were evaluated in in vitro tests and compared with the flow patterns analyzed by flow visualization and computational fluid dynamic (CFD). Then our group tried to establish engineering guidelines to reduce hemolysis in the development of centrifugal blood pumps. The commercially available Nikkiso centrifugal blood pump (HPM-15) was used as a standard, and the dimensions of 2 types of gaps between the impeller and the casing, the axial and the radial gap, were varied. Four impellers with different vane outlet angles were also prepared and tested. Representative results of the hemolysis tests were as follows: The axial gaps of 0.5, 1.0, and 1.5 mm resulted in normalized index of hemolysis (NIH) values of 0.0028, 0.0013 and 0.0008 g/100 L, respectively. The radial gaps of 0.5 and 1.5 mm resulted in NIH values of 0.0012 and 0.0008 g/100 L, respectively. The backward type vane and the standard one resulted in NIH values of 0.0013 and 0.0002 g/100 L, respectively. These results revealed that small gaps led to more hemolysis and that the backward type vane caused more hemolysis. Therefore, the design parameters of centrifugal blood pumps could affect their hemolytic performances. In flow visualization tests, vortices around the impeller outer tip and tongue region were observed, and their patterns varied with the dimensions of the gaps. CFD analysis also predicted high shear stress consistent with the results of the hemolysis tests. Further investigation of the regional flow patterns is needed to discuss the cause of the hemolysis in centrifugal blood pumps.

Animals↗

Pore size of porous hydroxyapatite as the cell-substratum controls BMP-induced osteogenesis.

To elucidate the biochemical mechanism of osteogenesis, the effect of matrix geometry upon the osteogenesis induced by bone morphogenetic protein (BMP) was studied. A series of five porous hydroxyapatites with different pore sizes, 106-212, 212-300, 300-400, 400-500, and 500-600 microns, was prepared. A block (approximately 5 x 5 x 1 mm, 40.0 mg) of each hydroxyapatite ceramics was combined with 4 micrograms of recombinant human BMP-2 and implanted subcutaneously into the back skin of rat. Osteoinductive ability of each implant was estimated by quantifying osteocalcin content and alkaline phosphatase activity in the implant up to 4 wk after implantation. In the ceramics of 106-212 microns, the highest alkaline phosphatase activity was found 2 wk after implantation, and the highest osteocalcin content 4 wk after implantation, consistent with the results observed with particulate porous hydroxyapatite [Kuboki, Y. et al. (1995) Connect. Tissue Res. 32: 219-226]. Comparison of the alkaline phosphatase activities at 2 wk and the osteocalcin contents at 4 wk after implantation revealed that the highest amount of bone was produced in the ceramics implants with pore size of 300-400 microns. In the ceramics with smaller or larger pore sizes, the amount of bone formation decreased as the pore size deviated from 300-400 microns. The results indicated that the optimal pore size for attachment, differentiation and growth of osteoblasts and vascularization is approximately 300-400 microns. This study using chemically identical but geometrically different cell substrata is the first demonstration that a matrix with a certain geometrical size is most favorable for cell differentiation.

Alkaline Phosphatase↗

Application of hydrogen absorbing alloys to medical and rehabilitation equipment.

As power sources for rehabilitation equipment, electric, hydraulic, and pneumatic actuators have been used. However a more human-sized and higher powered actuator that can reduce the equipment size is desired. A new metal hydride (MH) actuator that uses the reversible reaction between the heat energy and mechanical energy of a hydrogen absorbing alloy has recently attracted much attention. The MH actuator is characterized by its small size, low weight, noiseless operation and a compliance similar to that of the human elbow joint. Therefore, the MH actuator has the characteristic of being light and easy to use and so is suitable for use in medical and rehabilitation applications. Some lifting devices using this actuator have already been developed and are being used for the care of the aged and disabled. The characteristics of the MH actuator are presented and then some applications are introduced in this paper. It is our opinion that in our aging society the MH actuator will play an important role in the development of medical and rehabilitation equipment.

Absorption↗

Effects of self washout structure on the antithrombogenicity and the hemolytic properties of a centrifugal pump.

Antithrombogenicity in an initial type (N1) of a centrifugal pump (CP) developed in our institute is provided by the central balancing hole of an impeller. A new CP (N2) was modified to obtain better antithrombogenicity, in which the balancing hole was widened to improve self washout flow velocity (Vsf), and an edge of the thrust bearing was rounded off to minimize flow separation. Effects of the modifications were assessed in vitro and in vivo studies. The Vsf of the N1 and the N2 evaluated by a Doppler velocimeter were 12.8 and 22.1 cm/s, respectively. Flow around the thrust bearing, which was visualized by a light cutting method, confirmed less flow stagnation in the N2. The hemolytic indices of the N1 and the N2 were 0.023 and 0.008 mg/dl, respectively. In vivo antithrombogenicity and the hemolytic properties of the N2 and the N1 were investigated without anticoagulation therapy in 3 goats. In each goat the N2 was driven for 1 week and exchanged for the N1, which was driven for the same period. Red thrombi at the thrust bearing were found in 2 N1s, and 2 small thrombi were on the impeller of another N1, whereas a thrombus of less than 1 mm3 at the TB was noted in 1 N2. Plasma free hemoglobin was not increased in either CP. These results indicate that the N2 has better antithrombogenicity and hemolytic properties than the N1.

Animals↗

Long-term evaluation of a nonpulsatile mechanical circulatory support system.

Antithrombogenicity of a centrifugal pump (CP) developed in our institute is provided by a central balancing hole (BH) in the impeller. A current CP, the National Cardiovascular Center (NCVC)-2, was ameliorated to improve antithrombogenicity, whereby the BH diameter was widened to improve self washout flow velocity, and an edge of the thrust bearing was rounded off to minimize flow separation. Effects of these modifications were assessed in a long-term in vivo experiment. The antithrombogenicity, hemolytic property, and mechanical durability of the NCVC-2 were investigated in 3 goats. The NCVC-2 was installed paracorporeally between the left atrium and the aorta and driven as long as possible at rotating speeds of about 2,800 rpm. The NCVC-2 ran for 50, 200, and 367+ days. The mean bypass flow rates were 6.8, 5.0, and 5.3 L/min, respectively. Creatinine, blood urea nitrogen (BUN), glutamic-oxaloacetic transaminase (GOT), and glutamic-pyruvic transaminase (GPT) did not increase until one week before termination. Plasma free hemoglobin was kept to a level less than 15 mg/dl, except for the last week of the second case. These results indicate that the NCVC-2 has excellent antithrombogenicity, an acceptable hemolytic property and the necessary durability for prolonged use.

Alanine Transaminase↗

Noninvasive pump flow estimation of a centrifugal blood pump.

A flow rate estimating method was investigated for a centrifugal blood pump developed in our institute. The estimated flow rate was determined by the power consumption, the rotating speed of the motor, and the hematocrit value. The power consumption and the rotating speed of the motor were measured with a wattmeter. The examinations were performed in a closed mock loop filled with goat blood with hematocrit values of 21.5%, 28%, 34%, and 42%. Measured values of blood viscosity were 2.47, 3.09, 3.71, and 5.07 mPa.s at a share rate of 37.5/s, respectively. A linear correlation between the power consumption and the pump flow rate was observed in all hematocrit values. But variations in hematocrit caused a difference in the flow rate up to 1.1 L/min at the same power consumption and rotating speed. Effects of blood viscosity on the flow estimation were corrected by the hematocrit value. The value of the coefficient of determination, R2, between the estimated flow rate and the measured flow rate was 0.988. These results may indicate that the flow estimating method calculated by the power consumption of the motor, the rotating speed, and the hematocrit value is useful in the clinical situation.

Animals↗

Influence of ventricular fibrillation on sympathetic nerve activity under biventricular bypass circulation.

Autonomic nerves play an important role in circulatory control. The characteristics of sympathetic nerve activity (SNA) during artificial circulation, however, are not well understood. In this study, we examined the influence of natural heart beating on the renal SNA (RSNA) using pulsatile 100% biventricular assistance and electrically induced ventricular fibrillation in anesthetized goats, whose heart rate and size are similar to the human heart's. Following induction of the ventricular fibrillation, the pulse-synchronous discharges in the RSNA did not change their periodicity and quantity significantly. It was concluded that the beating of the heart had little influence on the RSNA and was presumably not essential for maintaining nervous control of circulation as long as the circulation was maintained by an artificial heart.

Animals↗

A volume-controlled liquid ventilator with pressure-limit mode: imperative expiratory control.

Liquid ventilation with perfluorocarbon (PFC) has been considered to offer advantages over gas ventilation to respiratory distress syndrome patients. We developed a volume-controlled liquid ventilator with pressure-limit mode; inspiration is performed mechanically with an actuator under the preset limit of the intratracheal pressure (Paw); expiration is performed by gravity assistance. Oxygenation and CO2 removal of PFC are done with a membrane oxygenator. An endotracheal tube with a Paw monitor line was placed in 5 rabbits weighing 2.7 +/- 0.6 kg, and liquid ventilation was conducted with the condition that the upper and lower limits of Paw were 20 and -20 mm Hg, respectively. The best arterial pH and gas tension were examined. The averaged arterial pH and gas tension were examined. The averaged arterial pH. Pao2, Paco2, and Sao2 were 7.45 mm Hg, 369 mm Hg, 46.2 mm Hg, and 100% at the best values, respectively. Ventilatory conditions at the best values were as follows: ventilation rates, tidal volume peak Paw, average Paw, and trough Paw were 5-15 (11 +/- 4) times/min, 13.3-17.3 (15.6 +/- 1.4) ml/kg, 5-18 (12 +/- 5) mm Hg, -7-4 (-1 +/- 4) mm Hg, and -20(-)-6 (-13 +/- 5) mm Hg, respectively. Pressure-limit control of the system worked well, but in the initial 3 animals, fluorothrax, that is the leakage of PFC into thoracic cavity, was recognized at the Paw from 20 to 25 mm Hg after the upper pressure limit was raised to 25 mm Hg to improve Paco2. The fluorothrax seemed to be caused by excess end-expiratory residual volume. An expiratory control mechanism appears to be imperative for further improvement of our liquid ventilator.

Animals↗

Development of a centrifugal pump with improved antithrombogenicity and hemolytic property for chronic circulatory support.

A centrifugal pump with a unique structure has been developed for chronic support. The pump is driven by a magnetic coupling and has no rotating shaft, no seal around the rotating part, and a balancing hole at the center of the impeller and the thrust bearing. The pump was improved in stepwise fashion to realize good antithrombogenicity and low hemolysis. The first pump, the National Cardiovascular Center (NCVC)-0, had an impeller with 4 rectangular and curved vanes; 6 triangularly shaped curved vanes were employed in the second model, the NCVC-1, to reduce trauma to the blood. In the third design, the NCVC-2, the central hole was enlarged, and the thrust bearing shoulder was rounded so that blood washing was enhanced around the impeller; stream lines also were smoothed for improved antithrombogenicity. The hemolytic property of the device was evaluated in vitro with heparinized fresh goat blood; hemolysis indexes of the NCVC-0, -1, and -2 were 0.05, 0.01, and 0.006 g per 100 L, respectively. Antithrombogenicity of the pumps was examined in animal experiments as a left heart bypass device in goals weighing 52-75 kg. Six NCVC-0 pumps were driven for 14 to 33 (22.0 +/- 7.6) days in goats receiving the antiplatelet drug cilostazol orally. Four NCVC-1 pumps ran for 1 to 80 (28.5 +/- 30.6) days with the same drug regimen in 2 cases and with no anticoagulation therapy in 2 cases. After 3 preliminary 1-week tests of NCVC-2 pumps in animals, the pump was installed in 3 goats; 2 pumps were still running on the 182nd and 58th pumping day. Intracorporeal implantation also was attempted successfully. The results indicate that this pump has promising features for chronic support although longer term and additional evaluations are necessary.

Animals↗

Relationship between pump speed design and hemolysis in an axial flow blood pump.

In an attempt to reduce the hemolysis caused by axial flow blood pumps, we investigated whether the specific speed should be kept within the standard engineering range or whether pump speed should be minimized, thus making the specific speed beyond the standard range. Four pumps with 11.8 mm diameter impellers were designed to accommodate a flow of 5 L/min and a head of 100 mm Hg. The pumps were tested at 4 speeds: A, 14,000; B, 18,000; C, 22,000; and D, 26,000 rpm. Pump performance data were obtained, and the maximum point of total pump efficiency was found for each pump. The maximum efficiencies were A, 50%; B, 58%; C, 52%; and D, 53%. The specific speed of each pump recorded at the maximum efficiency point was calculated as A, 899; B, 954; C, 1,218; and D, 1,951 rpm. Hemolytic tests were performed with fresh goat blood in a closed, mock-loop circuit. Hemolytic indexes were A, 0.036; B, 0.22; C, 0.35; and D, 0.66. We have concluded that decreased hemolysis is correlated with a lower pump speed and that the specific speed for the lowest pump speed is less than the standard range. Having a specific speed outside the standard range was not correlated with reduced total pump efficiency.

Blood Flow Velocity↗

Tandem operation of a turbo blood pump (BP-80--type centrifugal pump) to reduce hemolysis.

When operating turbo blood pumps in tandem, the strength of shear stress is reduced, but the exposure duration of the stress is increased. The purpose of this experiment was to compare the degree of contribution of these two factors on hemolysis as well as to evaluate the effectiveness of the tandem operation of turbo blood pumps. Tandem operation of two Bio-pumps (BP-80; Medtronics Bio-medicus, Inc., Eden Prairie, Minnesota, U.S.A.) were compared with single operation of a BP-80 in in vitro hemolysis tests in three different driving conditions, that is, pumping heads of 200, 350, and 500 mm Hg under a pump flow rate of 5 L/min. The Allen's hemolytic indexes of the tandem operation at pumping heads of 200, 350, and 500 mm Hg were 0.014, 0.020, and 0.080 mg/dl, respectively. The hemolytic indexes of the single operation at pumping heads of 200, 35, and 500 mm Hg were 0.014, 0.056, and 0.12 mg/dl, respectively. These results indicate that tandem operation is a useful method of reducing hemolysis with the BP-80 under high pumping heads and that the effect on hemolysis of exposure to higher shear stresses may be more serious than that of longer durations of exposure to shear stress in turbo blood pumps.

Animals↗

Hemolysis and heat generation in six different types of centrifugal blood pumps.

What the most causative factor affecting hemolysis is still controversial. To resolve this problem, we investigated the relationship between hemolysis and heat generation in six types of centrifugal blood pumps (Bio-Pump, Delphin, Capiox, Nikkiso, Isoflow, and Toyobo). The analyzed parameters were index of hemolysis in fresh goat blood, pumping performance, and heat generation in a thermally isolated mock circuit. These parameters were analyzed at a flow rate of 5 L/min by changing the pressure head (100 mm Hg and 500 mm Hg). At 500 mm Hg of pressure head, the Bio-Pump needed the highest rotation number and showed the highest hemolytic rate and heat generation. The index of hemolysis is well correlated to heat generation (r2 = 0.721). Heat may originate from the motor by conduction, hydraulic energy loss, and mechanical friction between the shaft and seal. We strongly suspect that hemolysis was caused by a factor such as mechanical friction which generates heat locally.

Animals↗

A flow visualization study of the NCVC centrifugal blood pump.

A compact centrifugal pump, NCVC-1, has an open-type impeller with 6 curved vanes, and it is characterized by no shaft and no seal. A tunnel is placed in the center of the impeller-rotor assembly to irrigate the back space behind the rotor. To evaluate the flow, we performed 3 visualization methods: tracer, oil film, and injection streak line method. The flow, observed by the tracer method in NCVC-1, indicated little turbulence along vanes. A volute chamber proved effective to reduce vortex formation in the outlet. Oil film pattern revealed no flow separation on vanes at 5 L/min. Washout flow behind the rotor is essential to prevent thrombus formation and was shown as inward spiral flow without any stagnation. These data suggested that a combination of visualization techniques was useful to analyze various flow conditions, and the NCVC-1 has excellent flow characteristics with little turbulence and little flow stagnation, which must be beneficial to low hemolysis and high antithrombogenicity.

Heart-Assist Devices↗

A new porous hydroxyapatite ceramic prepared by cold isostatic pressing and sintering synthesized flaky powder.

A new porous hydroxyapatite ceramic was prepared by cold isostatic pressing and sintering of the flaky powder, that was synthesized through two-stage hydrolysis of brushite; (1) a structural change into the apatite structure and (2) a compositional increase in Ca/P ratio, according to the method of Monma and Kamiya. The appearance of the synthesized powder resembled the flaky shape of the starting materials and its average particle size was about 15 microns. This powder consisted of fine needle crystals, which had a tendency to grow into the larger grains, but the powder was highly resistant to sintering under the usual heating conditions at 1200 degrees C. Porous hydroxyapatite blocks and granules were prepared by cold isostatic pressing and sintering a pellet consisting of the hydroxyapatite powder and spherical polymer beads. The product showed a 70% apparent porosity with spherical pores, ranging from 100-200 microns in size, and most pores were interconnected. These properties were ascribed to the effect of cold isostatic pressing on the hydroxyapatite powders with the flaky shape.

Ceramics↗