PubMed Health⌕ Search

Biomedical subjects

Y Y Won

Publications and source records attributed to Y Y Won.

4 recordsLinked to original sources

The three-dimensional microstructure of the trabecular bone in the mandible.

This study investigated the three dimensional (3D) trabecular microstructure of the alveolar and basal bone in the mandible using micro-CT and compared the morphometric values of the different sites. Ten specimens were prepared and scanned using a micro-CT system. Both the alveolar and basal trabecular bone of the premolar region in the mandible were measured for the structural analysis. Cross-sectional 1024x1024 pixel images were created. From the two-dimensional (2D) images produced, 3D structural images were reconstructed. After scanning the specimen, the volumes of interest (VOI) of the alveolar and basal bone regions were selected from the 3D reconstruction images, and the structural parameters such as bone volume fraction, bone surface density, trabecular thickness, trabecular separation, trabecular number and structural model index were analyzed. The trabecular structure showed a marked variation within the sites of the specimen, especially in the basal trabecular bone inferior to the mandibular canal. In both the alveolar and basal bone regions, a mixture of both plate-like and rod-like structures was observed. The alveolar region showed a more compact, plate-type trabecular structure than the basal regions. In parametric comparison with the basal bone, the alveolar bone generally had a higher bone volume fraction, bone trabecular thickness and trabecular number, and lower bone surface density, trabecular separation and structural model index. The alveolar bone consisted of a compact bone structure with a large amount of thick plate-type trabecular bone, which was effectively resistant to the masticatory forces. As the measurements were made closer to the basal bone, a loose structure was observed with lower bone volume and fewer, thin, rod-like trabeculae.

Adult↗

Preparation, stability, and in vitro performance of vesicles made with diblock copolymers.

Vesicles made completely from diblock copolymers-polymersomes-can be stably prepared by a wide range of techniques common to liposomes. Processes such as film rehydration, sonication, and extrusion can generate many-micron giants as well as monodisperse, approximately 100 nm vesicles of PEO-PEE (polyethyleneoxide-polyethylethylene) or PEO-PBD (polyethyleneoxide-polybutadiene). These thick-walled vesicles of polymer can encapsulate macromolecules just as liposomes can but, unlike many pure liposome systems, these polymersomes exhibit no in-surface thermal transitions and a subpopulation even survive autoclaving. Suspension in blood plasma has no immediate ill-effect on vesicle stability, and neither adhesion nor stimulation of phagocytes are apparent when giant polymersomes are held in direct, protracted contact. Proliferating cells, in addition, are unaffected when cultured for an extended time with an excess of polymersomes. The effects are consistent with the steric stabilization that PEG-lipid can impart to liposomes, but the present single-component polymersomes are far more stable mechanically and are not limited by PEG-driven micellization. The results potentiate a broad new class of technologically useful, polymer-based vesicles.

2-Naphthylamine↗

Technical factors for success with metal ring acetabular reconstruction.

Sixty-four hips in 62 patients were revised with a Mueller ring (28 hips), Ganz ring (18 hips), and Burch-Schneider cage (18 hips) under the direction of a single surgeon. A polyethylene cup was cemented into the metal support of all hips. Average follow-up was 4.6 years (range, 2.0-6.7 years). Six rings were revised because of aseptic loosening, and 5 others were radiographically loose, for a mechanical failure rate of 11 of 64 (17%). Acetabular metal ring supports failed by migration when defects of > or =60% of the superior weight-bearing bone were filled by only cement or particulate graft. At the time of surgery, the superior rim of the metal support should be against host-bone for 60% of its support, and if not, the use of bulk allograft, rather than particulate graft, is required. Dislocation was the second failure mechanism identified, and this occurred in 15 hips (23%), with reoperation required in 5 hips (8%). A constrained liner should be used in patients with nonunion of the trochanter and preoperative abductor weakness that grades fair/minus or worse as measured by the side-lying abduction test.

Acetabulum↗

Polymersomes: tough vesicles made from diblock copolymers.

Vesicles were made from amphiphilic diblock copolymers and characterized by micromanipulation. The average molecular weight of the specific polymer studied, polyethyleneoxide-polyethylethylene (EO40-EE37), is several times greater than that of typical phospholipids in natural membranes. Both the membrane bending and area expansion moduli of electroformed polymersomes (polymer-based liposomes) fell within the range of lipid membrane measurements, but the giant polymersomes proved to be almost an order of magnitude tougher and sustained far greater areal strain before rupture. The polymersome membrane was also at least 10 times less permeable to water than common phospholipid bilayers. The results suggest a new class of synthetic thin-shelled capsules based on block copolymer chemistry.

Chemical Phenomena↗