PubMed Health⌕ Search

Biomedical subjects

Y Yaguchi

Publications and source records attributed to Y Yaguchi.

At least 19 recordsLinked to original sources

Hemodynamic responses among three tracheal intubation devices in normotensive and hypertensive patients.

UNLABELLED: We compare hemodynamic responses in normotensive and hypertensive anesthetized paralyzed patients among three intubation devices: the Macintosh laryngoscope (LS), the Trachlight lightwand (LW), and the intubating laryngeal mask airway Fastrach (ILM). Seventy-five normotensive and 75 hypertensive patients were randomly assigned to each intubation device (n = 25). Noninvasive systolic blood pressure (SBP) and diastolic blood pressure (DBP) and heart rate (HR) were recorded immediately preinduction, immediately preintubation, and every minute for the first 5 min after the successful intubation. The number of intubation attempts, the time to successful intubation, and any airway injuries were recorded. Pharyngolaryngeal morbidity was assessed 18-24 h after surgery by a blinded investigator. In all groups, there was a reduction in SBP and DBP but no change in HR immediately preintubation compared with baseline values. In all groups, HR increased, but there were no increases in SBP and DBP other than in DBP in the LS/hypertensive group after intubation compared with baseline values. In normotensive patients, there were no differences in any hemodynamic variables among the three devices. In hypertensive patients, SBP and DBP in the LS group were significantly higher than the ILM and LW groups for 2 min after intubation, but there were no differences in HR among the devices. The number of intubation attempts was similar among groups, but intubation time was longer for the ILM group. The incidence of airway injury was more frequent for the ILM than the LS and LW groups (16% versus 0% versus 0%). There were no differences in pharyngolaryngeal morbidity among groups. We conclude that both the ILM and the LW attenuated the hemodynamic stress response to tracheal intubation compared with the LS in hypertensive, but not in normotensive, anesthetized paralyzed patients. IMPLICATIONS: Both the intubating laryngeal mask airway Fastrach and the Trachlight lightwand attenuate the hemodynamic stress response to tracheal intubation compared with the Macintosh laryngoscope in hypertensive, but not in normotensive, anesthetized paralyzed patients.

Aged↗

Intubating laryngeal mask airway size selection: a randomized triple crossover study in paralyzed, anesthetized male and female adult patients.

UNLABELLED: We determined the optimal size of intubating laryngeal mask airway (ILM) for ventilation and blind tracheal intubation in men and women. We also determined the distance the tracheal tube needs to protrude beyond the distal aperture to ensure that the cuff is through the vocal cords. Fifty male and 50 female anesthetized, paralyzed patients (ASA physical status I or II, aged 18-80 yr) were studied. Three operators (A, B, and C) were involved for the purposes of blinding. The size 3, 4, or 5 ILM was inserted into each patient in random order by Operator A, and the quality of ventilation was scored (adequate, suboptimal, or failed) by Operator B. The fiberoptic position (correct, too shallow, or too deep) and the distance between the distal aperture and the vocal cords was determined by Operator B. A single attempt at blind intubation was made by Operator C. Operators B and C were blinded to the size of the ILM. Operator C was also blinded to the information recorded by Operator B. All ILMs were inserted into the laryngopharynx at the first attempt. For men and women, the ventilation score was smaller for the Size 3 than the Size 4 or 5 (all: P < 0.002). For men, correct positioning was less common with the Size 3 than the Size 4 or 5 (both: P < 0.02). For women, correct positioning was similar among sizes. For men, tracheal intubation was successful less frequently with the Size 3 (84%) than the Size 4 (100%) or 5 (98%) (both: P < or = 0.01). For women, tracheal intubation success was similar among sizes (Size 3, 4, and 5: 86%, 96%, and 92%, respectively). Intubation was always successful if the ILM was correctly positioned and always failed if it was too shallow or deep. In both male and female patients, the distance between the distal aperture and the vocal cords increased with increasing ILM size (all: P < 0.04) and patient height (P < 0.0001) and was always longer for men (all: P < 0.0001). The overall mean distance (95% confidence interval) that the tracheal tube needed to protrude was 10-12 cm (8-13 cm) in men and 8-11 cm (8-12 cm) in women. We conclude that for men, the Size 4 and 5 ILMs are better than the Size 3 for ventilation and blind intubation. For women, the Size 4 and 5 ILMs are better than the Size 3 for ventilation, but there is no difference among sizes for blind intubation. The length the tracheal tube must protrude from the distal aperture to ensure that the cuff is completely through the vocal cords is 8-13 cm, depending on ILM size, the tracheal tube size, and the sex and height of the patient. IMPLICATIONS: For men, the Size 4 and 5 intubating laryngeal mask airways are better than the Size 3 for ventilation and blind tracheal intubation. For women, the Size 4 and 5 are better than the Size 3 for ventilation, but there is no difference among sizes for blind intubation. The length the tracheal tube must protrude from the distal aperture of the intubating laryngeal mask airway to ensure that the cuff is completely through the vocal cords is 8-13 cm, depending on the size of the mask and tracheal tube and on the sex and height of the patient.

Adolescent↗

Routine use of the intubating laryngeal mask airway results in increased upper airway morbidity.

PURPOSE: The classic laryngeal mask airway (LMA) has a soft, silicone tube and the intubating laryngeal mask airway (ILM) has a rigid, silicone-coated steel tube. We compare postoperative pharyngolaryngeal morbidity in patients randomised to receive either device. METHODS: Sixty-five female patients (ASA physical status class I or II, aged 18-80 yr) undergoing balanced regional anesthesia for gynecological laparotomy expected to last one to two hours were randomly assigned for airway management with the LMA or ILM. Intracuff pressure was maintained at 60 cm H20. Postoperative pharyngolaryngeal morbidity (sore throat, difficulty swallowing, sore mouth, sore neck/jaw, hoarseness) was assessed at two, 24 and 48 hr by blinded investigators. RESULTS: The number of insertion attempts and duration of anesthesia was similar between groups. Sore throat was more common for the ILM at two hours (44 vs 15%, P=0.01), 24 hr (59 vs 21%, P=0.008) and 48 hr (34 vs 3%, P=0.005). Sore mouth was more common for the ILM at two hours (16 vs 0%, P=0.02) and 24 hr (12 vs 0%, P=0.04), but not at 48 hr (6 vs 3%). Difficulty swallowing was more common for the ILM at two hours (25 vs 0%, P=0.04), but not at 24 hr (31 vs 3%) and 48 hr (12 vs 9%). There were no differences in the incidence of sore jaw/neck (ILM, 3-12%; LMA, 0-3%) and hoarseness (ILM, 12-31%; LMA, 16-18%). There was no correlation between postoperative pharyngolaryngeal morbidity and duration of anesthesia. CONCLUSION: Pharyngolaryngeal morbidity is more common with the ILM than the LMA following anesthesia lasting one to two hours.

Adolescent↗

Haemodynamic responses to the intubating laryngeal mask and timing of removal.

We determined (a) the haemodynamic responses to intubating laryngeal mask (ILM) airway insertion/intubation and removal in anaesthetized patients, and (b) whether the timing of ILM removal influences these responses. One-hundred and twenty patients without cardiovascular disease were studied. ILM airway insertion/intubation was 5 min after induction with propofol 2 mg kg(-1) and maintenance of anaesthesia with sevoflurane 2% in oxygen 33% and nitrous oxide. Patients were randomly assigned for removal of the intubating laryngeal mask airway at 1, 3 and 5 min after successful intubation. Systolic and diastolic arterial pressures and heart rate were recorded preinduction (baseline), before ILM airway insertion/intubation, at 1-min intervals after insertion/intubation, and at 1-min intervals for 5 min after ILM removal. ILM insertion was successful at the first attempt in all patients, but 46 patients required more than one intubation attempt. Compared with baseline values, there were no increases in systolic or diastolic arterial pressure, but there was an increase in heart rate 1 min after ILM insertion/intubation (9%, P<0.001) and 1 min after ILM removal (8%, P<0.01). There was a significant increase in systolic and diastolic pressures and heart rate 1 min after ILM insertion/intubation (30%, 31% and 15%; all: P<0.002) compared with before ILM insertion/intubation values and 1 min after ILM removal (9%, 8% and 7%; all P<0.05) compared with 1 min after ILM insertion/intubation values. Removal of the ILM 1 min after successful intubation resulted in higher arterial pressure compared with removal at 3 min (systolic arterial pressure 10% higher for 1 min, P = 0.01) and 5 min (systolic arterial pressure 10-23% higher for 3 min, P<0.01; diastolic arterial pressure 10-20% higher for 4 min, P>0.02), but there were no differences in heart rate between groups. Systolic and diastolic arterial pressures were greater if more than one intubation attempt was required. Early removal or multiple intubation attempts did not exceed baseline haemodynamic values. We conclude that ILM insertion/intubation and removal in anaesthetized patients produces little or no haemodynamic response, even if multiple intubation attempts are required. The timing of removal exerts a small, but clinically unimportant influence on these responses.

Adult↗

Reduction in standard MAC and MAC for intubation after clonidine premedication in children.

We examined the relative effects of different doses of oral clonidine on the MAC for endotracheal intubation (MACEI) and the MAC for skin incision (MAC) in children. We studied 90 children (15 in each group) (age range 2-8 yr, weight 10-27 kg, height 89-124 cm) who received one of three preanaesthetic medications: placebo (control), oral clonidine 2 micrograms kg-1, or oral clonidine 4 micrograms kg-1 100 min before anaesthesia. Anaesthesia was induced and maintained with sevoflurane in oxygen and air without i.v. anesthetics and neuromuscular relaxants. The end-tidal sevoflurane concentration was kept constant for > or = 15 min before tracheal intubation or skin incision. MACs were determined using Dixon's 'up-and-down method'. Mean (SD) MACEIs of sevoflurane were 2.9 (0.1)%, 2.5 (0.1)% and 1.9 (0.1)% (P < 0.05), and MACs were 2.3 (0.1)%, 1.8 (0.1)% and 1.3 (0.1)% (P < 0.05), respectively, in control, clonidine 2 micrograms kg-1 and clonidine 4 micrograms kg-1 groups. The MACEIs and MACs decreased dose-dependently. The MACEI/MAC ratio (1.4) was not affected by clonidine.

Adrenergic alpha-Agonists↗

Segmental cervical spine movement with the intubating laryngeal mask during manual in-line stabilization in patients with cervical pathology undergoing cervical spine surgery.

UNLABELLED: We quantified the extent and distribution of segmental cervical movement produced by the intubating laryngeal mask (ILM) during manual in-line stabilization in 20 anesthetized patients with cervical pathology undergoing cervical spine surgery. All patients had neurological symptoms preoperatively. The ILM was inserted with the head and neck in the neutral position. Intubation was facilitated by transillumination of the neck with a lightwand. Cervical movement was recorded with single-frame lateral radiographic images taken 1) immediately before induction (baseline); 2) during ILM insertion (insertion); 3) when transillumination was first seen at the cricothyroid membrane (intubation A); 4) when the tube was being advanced into the trachea (intubation B); and 5) during ILM removal (removal). Radiographic images were digitized and the degree of flexion/extension and posterior movement measured for the occiput (C0) through to C5. During ILM insertion, C0-5 were flexed by an average of 1-1.6 degrees (all P < 0.05). During intubation A/B, C0-4 were flexed by an average of 1.4-3.0 degrees (all P < 0.01), but C5 was unchanged. During ILM removal, C0-3 were flexed by an average of 1 degree (all: P < 0.05), but C3-5 were unchanged. During insertion and intubation A/B, C2-5 were displaced posteriorly by an average of 0.5-1.0 mm (all: P < 0.05). During removal, there was no change at C1-5. Neurological symptoms improved in all patients. We conclude that the ILM produces segmental movement of the cervical spine despite manual in-line stabilization in patients with cervical spine pathology undergoing cervical spine surgery. This motion is in the opposite direction to direct laryngoscopy, suggesting that different approaches to airway management may be more appropriate depending on the nature of the cervical instability. IMPLICATIONS: The intubating laryngeal mask produces segmental movement of the cervical spine, despite manual in-line stabilization in patients with cervical spine pathology undergoing cervical spine surgery. This motion is in the opposite direction to direct laryngoscopy, suggesting that different approaches to airway management may be more appropriate depending on the nature of the cervical instability.

Aged↗

The awakening concentration of sevoflurane in children.

UNLABELLED: Sevoflurane is frequently used as a rapidly acting drug for the induction of anesthesia. We investigated the awakening concentration (MAC-awake) of sevoflurane in ASA physical status I children (age range 2-10 yr). We also investigated the effects of two different doses of clonidine (2 and 4 microg/kg) on the MAC-awake of sevoflurane. Subjects were randomly divided into three groups and received placebo (n = 24), clonidine 2 microg/kg (n = 17), or clonidine 4 microg/kg (n = 22) orally, 100 min before the induction of anesthesia. Sedation scores were estimated, by using a five-point scale, after entry into the operating room, and anesthesia was induced and maintained with sevoflurane in oxygen and balanced nitrogen, without an additional anesthetic. After surgery, end-tidal sevoflurane was decreased stepwise by 0.2% at 15-min intervals, a standardized verbal command was played to the patients, and the MAC-awake was determined. The MAC-awake of sevoflurane alone was 0. 78% +/- 0.24% (mean +/- SD), which decreased to 0.36% +/- 0.09% and 0.36% +/- 0.16% (both P <0.0001, compared with the control group) after premedication with the small and large doses of clonidine, respectively. The lack of any dose-response relationship might be explained by a plateau effect. IMPLICATIONS: The awakening concentration of sevoflurane in unpremedicated children was 0.78%. Oral clonidine premedication at a dose of 2 microg/kg reduced the awakening concentration to 0.36%. However, an additional decrease in this value was not observed after the administration of the larger dose of clonidine premedication (4 microg/kg).

Administration, Oral↗

Effects of Fusobacterium necrophorum subspecies necrophorum on extracellular matrix of tissue-cultured bovine kidney cells.

The effects of Fusobacterium necrophorum subsp. necrophorum on the extracellular matrix were investigated. The toxic preparation from the culture induced reduction in the number of tissue-cultured bovine kidney cells. The exposed cells often manifested partial loss of cytoplasm and were morphologically irregular. Scanning electron microscopy demonstrated partial loss of the microvilli on the exposed cells and roughness of the cell surfaces. Finally, sodium dodecyl sulphate polyacrylamide gel electrophoresis profiles revealed complete degradation of bovine collagen type 1 after treatment with the toxic preparation. This degradation was inhibited by the addition of homologous antiserum. These findings indicate that the degradation may contribute to the establishment of the infection caused by F.n. subsp. necrophorum.

Animals↗

[Pulmonary Mycobacterium gordonae infection treated with clarithromycin].

We reported a case of 51-year-old female immunocompetent patient with pulmonary Mycobacterium gordonae infection. The patient complained persistent cough and sputum and occasionally hemosputum. Chest radiograph and computed tomography (CT) of the lung showed bronchiectasis and small nodules in middle lobe. Bronchofiberscopy was performed twice, and bronchial washing specimen repeatedly revealed acid-fast bacilli. The organism was identified as Mycobacterium gordonae by biochemical tests and direct sequence method. She was treated with clarithromycin (400 mg/day) over 6 months and the chest CT findings showed improvement. The case was considered to be sensitive to clarithromycin in vitro drug susceptibility test. The case suggested that clarithromycin was a useful therapeutic agent to Mycobacterium gordonae infection.

Clarithromycin↗

End-tidal sevoflurane concentration for tracheal extubation (MACEX) in adults: comparison with isoflurane.

Sevoflurane has a non-pungent odour and provides smooth induction of anaesthesia. In contrast, isoflurane is irritating to the airway when used for induction, and this may also be evident during emergence from anaesthesia. We measured the end-tidal concentration of anaesthetic that prevented response to extubation in 50% of patients (MACEX) in adults receiving either sevoflurane or isoflurane. Airway complications during emergence from anaesthesia were also noted. We studied 51 adult patients, ASA 1, aged 36-59 yr. Patients received sevoflurane (n = 29) or isoflurane (n = 22) for elective intraocular surgery. The concentration at which extubation was attempted was determined by a modification of Dixon's up-and-down method. When tracheal extubation was accomplished without coughing and gross purposeful muscular movements within 1 min after extubation, it was considered a smooth tracheal extubation. Patients who developed breath-holding or laryngospasm immediately after tracheal extubation were regarded as not having been extubated smoothly. In addition, patients were observed for respiratory events during the remainder of the emergence period. MACEX values for sevoflurane and isoflurane were 1.07% and 0.83%, respectively. ED95 values of sevoflurane and isoflurane were 2.04% and 1.19%, respectively. In 12 patients in the isoflurane group, extubation was smooth but six patients had coughing episodes during the remainder of the emergence period. In contrast, one of 15 patients in the sevoflurane group in whom tracheal extubation was smooth coughed later (P = 0.035). Airway obstruction was frequent when tracheal extubation was performed at end-tidal concentrations exceeding 1 MACEX for each anaesthetic.

Adult↗

The effects of clonidine premedication on sevoflurane requirements and anesthetic induction time.

UNLABELLED: We assessed the effects of oral clonidine preanesthetic medication (4.5 microg/kg) on the vital capacity rapid-inhalation anesthetic induction time (VCRII time) and minimum alveolar anesthetic concentration (MAC) to prevent a response to a verbal command in 50% of patients (MAC-Awake) by its hypnotic effect, and on MAC-Skin incision for the analgesic effect in patients anesthetized with sevoflurane. We studied 104 adult patients (control group: n = 52, clonidine group: n = 52) aged 30-48 yr scheduled to undergo general anesthesia. Fifty-two patients received oral clonidine 4.5 microg/kg 1.5 h before arrival in the operating room (clonidine group). The patients exhaled to residual volume and took three vital capacity breaths of 5% sevoflurane in oxygen. The VCRII time was defined as the time interval between the initiation of the VCRII and the disappearance of the response to verbal command. Anesthesia was maintained with sevoflurane in oxygen and air. The end-tidal (ET) sevoflurane concentration reached a predetermined value, then the ratio of predetermined ET to inspiratory concentration was maintained at > or =0.95 for at least 15 min before skin incision. After skin incision, the patients were observed for gross purposeful muscular movements. MAC was defined as the average of the cross-over midpoints in each cross-over. After maintaining the ET sevoflurane concentration for 15 min, patients were judged to be awake or asleep. Average times for VCRII using 5% sevoflurane were achieved in 44+/-11 s (mean +/- SD) and 27+/-6 s in the control and clonidine groups, respectively (P = 0.0001). MAC-Awake values of sevoflurane were 0.66%+/-0.03% and 0.35%+/-0.02% (P = 0.0001), and MAC-Skin incision values were 1.97%+/-0.19% and 1.29%+/-0.13% (P = 0.0001) in the control and clonidine groups, respectively. These results suggest that clonidine may have a more potent hypnotic effect than analgesic effect. IMPLICATIONS: Oral clonidine preanesthetic medication (4.5 microg/kg) significantly reduces vital capacity rapid inhalation anesthetic induction time and minimum alveolar anesthetic concentration awake for sevoflurane.

Adult↗

Adherence of Fusobacterium necrophorum subspecies necrophorum to different animal cells.

The adherence of Fusobacterium necrophorum subsp. necrophorum to the surfaces of animal cells was studied in order to elucidate the differences between the bacterial appearance in clinical specimens from various animals. The bacterial cells had a strong affinity for murine and rabbit cheek cell surfaces. The bacterium showed a moderate affinity for goat cells, whereas it adhered not so well to canine, feline, human or porcine cells. Treatment of the bacterial cells with haemagglutinin antiserum prior to the binding assay reduced the degree of attachment to murine and rabbit cells. Scanning electron microscopy revealed that the adherent fusobacteria often penetrated into murine and rabbit cell membranes. These observations indicate that the bacterial attachment contributes to the establishment of the infection in mice and rabbits. It is suggested that the weak binding ability resulted in a low incidence of the bacterium in canine, feline and porcine lesions.

Adult↗

Anaesthetic induction time for tracheal intubation using sevoflurane or halothane in children.

The current study was designed to determine the anaesthetic induction time required for tracheal intubation (TimeEI) with equipotent inspired concentrations of 5% sevoflurane and 2.5% halothane in oxygen. TimeEI that prevents 50% and 95% of patients from coughing and gross purposeful muscular movements after intubation was defined as TimeEI50 and TimeEI95, respectively. Thirty-six patients aged 1-7 years were enrolled in the study. Anaesthesia was induced via mask and when TimeEI attained a predetermined value, intubation was performed using an uncuffed tube. Each TimeEI at which tracheal intubation was attempted was predetermined according to the up-and-down method. When intubation was accomplished without gross purposeful muscular movements, it was considered a smooth intubation. Determination with this method revealed that TimeEI50 and TimeEI95 for the sevoflurane/halothane groups were 147/214 s and 194/255 s, respectively. In conclusion, it is possible to determine TimeEI using an inspired sevoflurane concentration of 5% and halothane 2.5% in oxygen. The technique with 5% sevoflurane seems more practical for paediatric anaesthesia induction in busy clinical situations.

Anesthetics, Inhalation↗

Detection of cytotoxic effects of Clostridium novyi type A on bovine kidney cells.

The cytotoxic effects of a toxic preparation from Clostridium novyi type A were demonstrated on tissue-cultured bovine kidney cells. The cytotoxic response was dose-dependent and could be neutralized by homologous antiserum. Scanning electron microscopy revealed damaged kidney cell surfaces. These findings indicated that the cytotoxicity may contribute to the formation of the foci in bovine tissue during an infection with C. novyi.

Animals↗

Detection of antioxidant enzyme activities in renal tissues of early stage IgA nephropathy in ddY mice.

The purpose of this study was to determine the antioxidant enzyme activities in renal tissues of early stage ddY mice, an animal model for primary IgA nephropathy. Eight- and 40-week-old ddY female mice and normal healthy Balb/c female mice were used in this study. The levels of Cu/Zn-SOD, Mn-SOD, and GSH-PX activities in the renal cortex were significantly higher in 40-week-old ddY mice than in Balb/c control mice of the same age; no change of catalase activity was observed. There were no significant differences in the levels of Cu/Zn-SOD, Mn-SOD, GSH-PX, and catalase activities between the ddY mice and Balb/c mice at 8 weeks of age. Urinary protein was slightly higher in 40-week-old ddY mice. IgA or C3 was deposited at low levels in the glomerular mesangial areas of 8-week-old ddY mice. Marked depositions of IgA and C3 extended from the glomerular mesangial areas to the capillary walls of 40-week-old ddY mice. Expansion of glomerular mesangial matrices and mild mesangial cell proliferation was observed in 40-week-old ddY mice. Antioxidant enzyme activities in the renal cortex were already increased in the early stage IgA nephropathy in 40-week-old ddY mice. These findings suggest that measurements of antioxidant enzyme activities in the renal cortex of 40-week-old ddY mice was useful for evaluation of the pathogenesis of renal involvement in the early stage of IgA nephropathy.

Animals↗

A "bubble-tip" (Airguide) tracheal tube system: its effects on incidence of epistaxis and ease of tube advancement in the subglottic region during nasotracheal intubation.

Epistaxis and tubal obstruction in the subglottic region are difficulties encountered during nasotracheal intubation. Trauma to the nasal airway must be avoided, especially in patients receiving anticoagulant therapy. In addition, smooth passage of the tracheal tube through the larynx is desired. The tip of an Airguide tracheal tube system has a soft, round, glossy balloon head which should be less traumatic to the nasal mucosa than other more commonly used tubes. We, therefore, determined whether the Airguide reduces the incidence of epistaxis and increases smooth passage of the tracheal tube in the subglottic region during nasotracheal intubation. Sixty-six patients were divided into two groups, Airguide (n = 39) and Standard (n = 27). Each group was divided into two subgroups, topical epinephrine application as a mucosal decongestant and non-epinephrine. The incidences of epistaxis and smooth passage were compared between the two groups. The Airguide group had a significantly lower incidence of epistaxis (9/39 vs 13/26; P < 0.05; bleeding was not checked in one patient in the Standard group) and provided a significantly smoother passage in the subglottic region than the Standard group (tube impingement in the subglottic region, 0/39 vs 11/27; P < 0.01). There was no significant difference in the incidence of epistaxis between the subgroups with and without topical application of epinephrine. The Airguide helps to minimize epistaxis and increases navigability in the subglottic region during nasotracheal intubation.

Epistaxis↗