PubMed Health⌕ Search

Biomedical subjects

Ya-Feng Guan

Publications and source records attributed to Ya-Feng Guan.

3 recordsLinked to original sources

A windowless flow cell-based miniaturized fluorescence detector for capillary flow systems.

A miniaturized fluorescence detector utilizing a three-dimensional windowless flow cell has been constructed and evaluated. The inlet and outlet liquid channels are collinear and are located in the same plane as the excitation paths, while the optical fiber used to collect the emission light is perpendicular to this plane. The straightforward arrangement of the flow path minimizes band dispersion and eliminates bubble formation or accumulation inside the cell. The use of high-brightness light-emitting diodes (LEDs) as the excitation source and a miniaturized metal package photomultiplier tube (PMT) results in a compact and sensitive fluorescence detector. The detection limit obtained from the system for fluorescein isothiocyanate (FITC) in flow injection mode is 2.6 nmol/L. The analysis of riboflavin and FITC by packed capillary liquid chromatography is demonstrated.

Journal Article↗

[A novel light-emitting diode-induced fluorescence detector for micro-scale flow analysis system].

A compact light-emitting diode-induced fluorescence detector based on collinear scheme is described. The detector was assembled by all-solid-state optical-electronic components and easily coupled with micro-scale flow analysis system by on-column detection mode. Fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used as test analytes to evaluate the detector performance by capillary electrophoresis and flow injection analysis techniques. The concentration limit of detection was 10(-8) mol x L(-1) for FITC-labeled phenylalanine at a signal-to-noise ratio (S/N) of 3 (on-column, 0.05 mm i.d.). The system exhibited a good linear response in the range of 1 x 10(-7) -2 x 10(-5) mol x L(-1) (r2 = 0.999). The relative standard deviation (RSD) of 6 repetitive injections on peak heights is less than 3%.

English Abstract↗

[Application of electroosmotic pump on micro column liquid chromatography].

An electroosmotic pump(EOP) was designed and evaluated, which could replace the mechanical pump. The EOP could generate 2.0 MPa-6.0 MPa output pressure and tens of nL/min-3 microL/min flow rate. A test mixture containing naphthalene, anthracene and phenanthrene was separated on a 14 cm x 320 microns i.d., 5 microns, C18 micro column with acetonitrile/water as a mobile phase, which demonstrated the applicability of the EOP.

Anthracenes↗