PubMed Health⌕ Search

Biomedical subjects

Yadong Li

Publications and source records attributed to Yadong Li.

59 records · Page 4Linked to original sources

Cadmium biomonitoring and renal dysfunction among a population environmentally exposed to cadmium from smelting in China (ChinaCad).

Cadmium, an environmental pollutant, can have adverse effects on the human body. The kidney is the critical organ. In order to improve the understanding of the dose-response relationship between cadmium exposure and health effects, and especially renal dysfunction, a study on a general population group in China was performed. This study was therefore concerned with cadmium exposure biomarkers, such as the concentrations in blood (BCd) and urine (UCd), and effect biomarkers of renal dysfunction, such as beta2-microglobulin (beta2m), retinol binding protein (RBP) and albumin (ALB). To improve the evaluation of exposure levels in relation to the adverse health effects of cadmium exposure in the general population, a quality control program was conducted to determine analytical quality in the determination of cadmium in blood and urine and for beta2m, creatinine, ALB and RBP. The measurements showed that analytical quality was adequate. The exposure and effect biomarkers were studied in the population groups living in three areas, namely a control area and two Cd polluted areas. In the highly exposed area, most of the BCd values were higher than 5 microg/l and most of the UCd values were higher than 5 microg/g creatinine. Beta2-microglobulin, retinol binding protein, and albumin in urine were all significantly higher in the population living in the heavily polluted area than in that in the control area. Based on data from all three areas, a marked dose-response relationship between UCd or BCd and the prevalence of renal dysfunction was demonstrated. The number of abnormalities in kidney was related to the level of cadmium exposure. Only one index of renal tubular dysfunction was affected in subjects exposed to low levels of cadmium, but more than two indices of renal function were affected in those exposed to high levels.

Air Pollutants↗

A test phantom for estimating changes in the effective frequency of an ultrasonic scanner.

OBJECTIVE: Ultrasonic frequency is an important performance feature of B-mode scanners. It is particularly relevant when comparing instruments from different manufacturers and reporting clinical results. We investigated a test phantom to independently measure an effective imaging frequency, including effects of depth-dependent attenuation and frequency filtering during echo reception. METHODS: The approach capitalizes on variations of the frequency dependence of backscatter with scatterer size. A tissue-mimicking phantom containing 48-microm-diameter scatterers was constructed. Embedded at depths of 1, 3, 7, and 9 cm were sets of cylindrical inclusions, each containing tissue-mimicking material with a different scatterer size and number density. Computer simulations helped establish scatterer parameters for the cylinder bodies that resulted in image contrast versus the background that varied with frequency, with each cylinder transitioning from negative to positive contrast at a different frequency. Acoustic properties of the phantom were verified by a laboratory apparatus. Initial tests of the effectiveness of the phantom were done by imaging with several scanners using various frequency and imaging settings on transducers. RESULTS: Images were obtained with 2 clinical scanners in which modest changes in the image acquisition parameters were adjusted. Image contrast between test cylinders and background corresponded to operating frequency with a multihertz transducer. Changes in observable contrast consistent with a shift in operating frequency were not always accompanied by visual indicators that such changes in the scanning protocol had occurred. CONCLUSIONS: The test phantom performs as predicted by computer simulations and theoretical calculations of backscatter versus frequency. Contrast on images of the test phantom produced by clinical systems correlates with scanner frequency settings, showing feasibility. Relative shifts in effective frequency and operating bandwidth can be assessed from these contrast differences between settings with this test phantom.

Humans↗

Room Temperature Synthesis of Metal Chalcogenides in Ethylenediamine.

Reaction of sulfur and selenium with elemental or ionic metals in liquid ethylenediamine at room temperature produced metal chalcogenides ME (M = Cu, Sn, Co(2+), Ni(2+), Mn(2+), or Pb(2+); E = S or Se), Ag(2)E, M(2)E(3) (M = Bi or Sb). The results showed that the products had a range of crystalline sizes from 10 to 100 nm. Some reactions produced molecular precursors. Heat treatment of these precursors at 250 degrees C under a N(2) atmosphere induced crystalline chalcogenides. The pre- and postheated metal chalcogenides were analyzed by X-ray diffraction (XRD). Some key compounds are analyzed by X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). The roles of ethylenediamine in the reaction system are also discussed in this report.

Journal Article↗