Sub-2 microm porous and nonporous particles for fast separation in reversed-phase high performance liquid chromatography.

One approach to achieve fast and efficient separations in packed column liquid chromatography (LC) is to reduce eddy diffusion and mass transfer resistance in the mobile phase using short columns packed with small particles. In this study, efficiencies of columns packed with 1.5 and 3.0 microm nonporous and porous particles were compared in reversed-phase LC using nitromethane and a protein as analytes. Nonporous particles provided overall higher efficiency at high linear velocities when nitromethane was used as solute; however, the efficiency difference diminished significantly when the particle size was reduced from 3 to 1.5 microm. Efficiencies for 1.5 microm nonporous particles were considerably higher than those for 1.5 microm porous particles at high linear velocities when a protein, alpha-chymotrypsinogen A (MW 25,000), was used as solute. In addition, the average retention factor for amylbenzene in a column packed with ACQUITY C(18) porous particles was approximately 16 fold higher than for Micra C(18) nonporous particles for aqueous mobile phase compositions containing from 40 to 75% acetonitrile. Pressure drop, sample loading capacity, and separation power were also evaluated and compared for porous and nonporous particles under practical conditions.

Chromatography, High Pressure Liquid↗

Ultrahigh pressure liquid chromatography using elevated temperature.

Fast liquid chromatographic (LC) methods are important for a variety of applications. Reducing the particle diameter (d(p)) is the most effective way to achieve fast separations while preserving high efficiency. Since the pressure drop along a packed column is inversely proportional to the square of the particle size, when columns packed with small particles (<2 microm) are used, ultrahigh pressures (>689 bar) must be applied to overcome the resistance to mobile phase flow. Elevating the column temperature can significantly reduce the mobile phase viscosity, allowing operation at higher flow rate for the same pressure. It also leads to a decrease in retention factor. The advantage of using elevated temperatures in LC is the ability to significantly shorten separation time with minimal loss in column efficiency. Therefore, combining elevated temperature with ultrahigh pressure facilitates fast and efficient separations. In this study, C6-modified 1.0 microm nonporous silica particles were used to demonstrate fast separations using a temperature of 80 degrees C and a pressure of 2413 bar. Selected separations were completed in 30 s with efficiencies as high as 220,000 plates m(-1).

Chromatography, High Pressure Liquid↗

Pseudolinear gradient ultrahigh-pressure liquid chromatography using an injection valve assembly.

The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).

Journal Article↗