Determination of trace levels of bromate in flour and related foods by ion chromatography.

In this paper, a method of determining trace levels of bromate in flour and related foods by ion chromatography with large volume injection has been proposed. The detection of bromate was performed with a suppressed conductivity detector after separation on an IonPac AS19 column with KOH as the gradient eluent. Parameters affecting the extraction efficiency of bromate, such as the flour-to-water ratio, extraction time, and temperature, were studied in detail. The optimized pretreatment process was then selected. By using the large volume injection technique, the solution detection limit was decreased to 0.5 microg/L. The linear range of this method was from 5 to 1000 microg/L, and the linear correlation coefficient was 0.9998. The method has been applied to the detection of bromate in flour and related foods, and different concentration levels of bromate were detected in various samples. The spiked recoveries ranged from 86 to 110%. The relative standard deviation (RSD) of the bromate peak height for the seven successive injections of the flour sample was 6.4%.

Bromates↗

Selenium speciation by high-performance anion-exchange chromatography-post-column UV irradiation coupled with atomic fluorescence spectrometry.

A technique for the speciation of selenomethylcysteine (SeMeCys), selenocystine (SeCys), selenite [Se(IV)] and selenomethionine (SeMet) was established in this paper using high-performance anion-exchange chromatography coupled with atomic fluorescence spectrometry (HPAEC-AFS). Analytes were separated on an AminoPac PA10 column and then digested by on-line ultraviolet (UV) irradiation, which destroyed organic compound structure. Hydride generation was used as an available sample introduction technique for atomic fluorescence detection. The detection limits of four compounds were 1-5 microg/L (250 microL injection, 10 times of the baseline noise). The relative standard deviations (RSDs), calculated from seven consecutive injections of 100 microg/L standard mixtures, were from 2 to 4%. Selenious yeast tablet, which had been proposed as selenium supplement, and human urine collected from a volunteer were analyzed. Good spiked recoveries from 86 to 103% were obtained.

Chromatography, High Pressure Liquid↗

Direct amino acid analysis method for speciation of selenoamino acids using high-performance anion-exchange chromatography coupled with integrated pulsed amperometric detection.

Speciation analysis of selenomethylcysteine (SeMeCys), selenomethionine (SeMet) and selenocystine (SeCys) has been performed using a direct amino acid analysis method with high-performance anion-exchange chromatography (HPAEC) coupled with integrated pulsed amperometric detection (IPAD). Three selenoamino acids could be baseline-separated from 19 amino acids using gradient elution conditions for amino acids and determined under new six-potential waveform. Detection limits for SeMeCys, SeMet and SeCys were 0.25, 1 and 20 microg/L (25 microL injection, 10 times of the baseline noise), respectively. The relative standard deviations (RSDs) of 200 microg/L SeMeCys, SeMet and SeCys were 3.1, 4.1 and 2.8%, respectively (n=9, 25 microL injection). The proposed method has been applied for determination of selenoamino acids in extracts of garlic and selenious yeast granule samples. No selenoamino acids were found in garlic. Both SeMet and SeCys were detected in selenious yeast tablet with the content of 45 and 129 microg Se/g, respectively. Selenoamino acids standards were spiked in garlic and yeast granule samples and the recovery ranged from 90 to 106%.

Amino Acids↗

Progress of solid-phase microextraction coatings and coating techniques.

Solid-phase microextraction (SPME) has been popular as an environmentally friendly sample pretreatment technique to extract a very wide range of analytes. This is partly owing to the development of SPME coatings. One of the key factors affecting the extraction performances, such as the sensitivity, selectivity, and reproducibility, is the properties of the coatings on SPME fibers. This paper classifies the materials used as SPME coatings and introduces some common preparation techniques of SPME coating in detail, such as sol-gel technique, electrochemical polymerization technique, particle direct pasting technique, restricted access matrix SPME technique, and molecularly imprinted SPME technique.

Cellulose↗

Optimizing the integrated pulsed amperometric multicycle step waveform for the determination of tetracyclines.

A method of modified integrated pulsed amperometric detection with multicycle step waveform (Multi-IPAD) following high-performance liquid chromatography (HPLC) was applied for the determination of tetracyclines (TCs) including dimethyltetracycline (DMTC), oxytetracycline (OTC) and tetracycline (TC). The key advantages of the Multi-IPAD are the abilities to enhance sensitivity and reproducibility and the ability to keep working electrode clean through the use of a high-frequent waveform alteration in integration step and the use of a cleaning potential, which is quite different from conventional three-step potential waveform. The analyses were carried out using the mobile phase of acetonitrile-water mixture solution (10:90, v/v) containing 1% perchloric acid on a C(18) column at a flow rate of 0.21 mL/min. The IPAD waveform parameters were optimized to maximize the signal-to-noise ratio (S/N) and successfully applied for the sensitive detection of TCs. The detection limits (S/N=3, 20 microL injected) were 0.07 mg/L for DMTC, 0.08 mg/L for OTC and 0.05 mg/L for TC. The peak height relative standard deviations (RSDs) of every compound for replicate injection (n=15) determined were below 4.6%.

Chromatography, High Pressure Liquid↗

Determination of several sugars in serum by high-performance anion-exchange chromatography with pulsed amperometric detection.

In this paper, a sensitive, simple and direct method for simultaneous determination of glucose, ribose, isomaltose and maltose in serum sample by high-performance anion-exchange chromatography coupled with integrated pulsed amperometric detection was developed. The four target analytes were easily and completely separated on an anion-exchange column at a flow-rate of 0.25 mL/min by binary step gradient elution in about 16 min and the two eluents were deionized water and 500 mM sodium hydroxide, respectively. The separated four analytes were detected directly by using a gold electrode and quadruple-potential waveform integrated pulsed amperometry without derivatization. Under the optimized conditions, when the injection volume was 25 microL, the detection limits (signal-to-noise ratio equal to 3) for glucose, ribose, isomaltose and maltose were 0.92, 7.50, 12.9 and 10.3 ng/mL, respectively. The calibration graphs of peak area for the four analytes were linear over two to three orders of magnitude with correlation coefficients greater than 0.998. R.S.D. of peak areas of the four analytes for five determinations were no more than 5.6%. The analytical method had been applied to the determination of glucose, ribose, isomaltose and maltose in real serum samples and good results with low relative standard deviation not more than 5.3% were obtained. The accuracy of the proposed method was tested by recovery measurements on spiked samples and good recovery results (98.1-107.9%) were obtained.

Carbohydrates↗

Comparisons of disposable and conventional silver working electrode for the determination of iodide using high-performance anion-exchange chromatography with pulsed amperometric detection.

The paper compared the performance of two kinds of silver working electrode in electrochemical detector-the disposable and conventional electrode for the determination of iodide using high-performance anion-exchange chromatography (HPAEC) hyphenated with pulsed amperometric detection (PAD). The comparisons were carried out on the time of equilibration, long and short-term reproducibility, limits of detection and linearity of calibration. Results showed that disposable working electrode manifested equal or better results than conventional working electrode and could be used for iodide analysis. Besides, the disposable electrode could work for consecutive 2660 min (about 44 h, 10 min needed for each run) with no degradation. Due to its "disposable" property, disposable working electrode could be discarded if the detection sensitivity decreased to 80% so the time for polishing and reconditioning was spared and good reproducible results could be obtained. At last, the disposable electrode was applied for the determination of iodide in soil and sea water samples with the spiked recovery ranging from 96-104% and the detection limit of 0.5 microg/L (10 microL injection, three times of the baseline noise).

Anion Exchange Resins↗

Comparative study on the analytical performance of three waveforms for the determination of several aminoglycoside antibiotics with high performance liquid chromatography using amperometric detection.

A preliminary comparative study was carried out on the analytical performances of a new six-potential waveform and other two detection waveforms, triple-potential waveform and quadruple-potential waveform. The analytical performances compared included signal response, background noise, signal/noise ratio and signal stability. Compared with triple-potential waveform and quadruple-potential waveform, the new six-potential waveform had higher signal response, signal/noise ratio, and sensitivity. As for determination reproducibility, the six-potential waveform also exhibited a slightly better performance than the other two waveforms. Under the selected experimental conditions based on the six-potential waveform, there is a linear correlation between peak area and concentration over two to three orders of magnitude for nine aminoglycoside antibiotics with a correlation coefficients better than 0.998 and the detection limits measured as three times the peak height signal-to-noise ratio for the nine aminoglycoside antibiotics were in the range of 0.0198-0.889 microg/mL. The proposed method had been used to analyze real gentamicin sulphate drug sample.

Aminoglycosides↗

Electrochemical preparation of composite polyaniline coating and its application in the determination of bisphenol A, 4-n-nonylphenol, 4-tert-octylphenol using direct solid phase microextraction coupled with high performance liquid chromatography.

For SPME-HPLC, metal wires with better mechanical strength are preferred over the fused silica fibers. In this article, a novel composite polyaniline (CPANI) doped with PEG and polydimethylsiloxane coating (CPANI fiber) was prepared on a stainless steel wire by a three-electrode system: the fiber was used as the work electrode, a calomel electrode and a platinum electrode were used as the reference and the counter electrodes, respectively. To evaluate the new CPANI coating, the coating was used to extract three kinds of phenols (bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol) in water samples by direct-SPME mode and then desorbed in commercial SPME-HPLC interface to separation. The extraction procedure was also optimized. Five real water samples were investigated. Good recoveries were gained when environmental samples were analyzed.

Aniline Compounds↗

[Application of high performance anion exchange chromatography for trace analysis of polarizable anions].

Polarizable anions such as Br-, S2O3(2-), I- and SCN- were separated using 45 mmol/L sodium hydroxide solution as the mobile phase on a high hydrophilic IonPac AS16 column. With a pulsed amperometric detector, the detection limits were 0.5, 0.2, 0.05 and 2 microg/L (25.0 microL injected, signal-to-noise ratio of 3) for Br-, S2O3(2-), I- and SCN. The relative standard deviation (RSD) range of trace anions was from 0.8% to 3.7% (n = 9). Under the same chromatographic conditions, these anions were also determined using a suppressed conductivity detector and the detection limits were 1, 1, 2 and 10 microg/L (25 microL injected, signal-to-noise ratio of 3), respectively. The RSD range was from 0.9% to 4.7% (n = 9). Comparing a pulsed amperometric detector with a conductivity detector, the former is 2 to 40 times more sensitive than the latter. For the determination of polarizable anions, a pulsed amperometric detector has higher selectivity, precision and sensitivity.

Anion Exchange Resins↗

Sensitivity enhancement of chlorinated phenols by continuous flow liquid membrane extraction followed by capillary electrophoresis.

This paper describes a new analytical system, based on the combination of continuous flow liquid membrane extraction (CFLME) enrichment and capillary electrophoresis (CE) separation, for analysis of chlorinated phenols in water samples. Five chlorinated phenols including 3-chlorophenol (3CP), 4-chlorophenol (4CP) 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP), and pentachlorophenol (PCP) were separated by CE with Tris/sodium dihydrogen phosphate solution containing methanol 1% (v/v) as the run buffer. CFLME related parameters were investigated and optimal enrichment was obtained by using 0.3 mol L(-1) Tris as acceptor and with a sample pH 5.0, a sample flow rate of 4.0 mL min(-1), and an enrichment sample volume of 150 mL. The detection limit (S/N= 3) was 6.9, 1.0, and 1.7 ng mL(-1) for DCP, PCP, and TCP, respectively. The reproducibility (RSD%, n = 6) was 5.7 for DCP, 2.5 for PCP, and 2.8% for TCP (n = 6). The proposed method was applied to the determination of chlorinated phenols in spiked water samples with relatively satisfactory recoveries.

Calibration↗

[Determination of anions, cations and organic acids in the oil field water by ion chromatography].

A method for the determination of anions, cations and organic acids in the oil field water with high chloride and sodium ions was developed by ion chromatography (IC) with a conductivity detector. The separation of the cations was achieved on an IonPac CS12A column with H2SO4 as the eluent. The separation of the anions and organic acids was achieved on an IonPac AS11-HC column with KOH as the eluent, and the detection was performed by a conductivity detection mode. The calibration graphs of peak area for all the analytes were linear over a wide range. The recoveries of the added standards were 90% - 110% . The relative standard derivations (RSDs) of the peak area of analytes were less than 8.0%. The detection limits for analytes ranged from 1.55 microg/L to 31.8 microg/L.

Chromatography, Ion Exchange↗

Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol.

The adsorptive potential of multiwalled carbon nanotubes (MWNTs) for solid-phase extraction of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol was investigated for the first time. The three analytes are quantitatively adsorbed on a MWNTs-packed cartridge, then the analytes retained on the cartridge are quantitatively desorbed with suitable amounts of methanol. Finally, the analytes in the methanol eluate are determined by high performance liquid chromatography-fluorometric detection. Parameters influencing the extraction efficiency, such as volume of the sample solutions, pH of the sample, and the eluent volume, were examined. Comparative studies showed that MWNTs were superior to C18 for the extraction of the more polar analyte bisphenol A and at least as effective as C18 for the extraction of 4-n-nonylphenol and 4-tert-octylphenol. Compared to XAD-2 copolymer, MWNTs exhibited a better property for the extraction of all three analytes. The developed method has been applied to determine bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol in several environmental water samples. The accuracy of the proposed method was tested by recovery measurements on spiked samples, and good recovery results (89.8-104.2%) were obtained. Detection limits of 0.083, 0.024, and 0.018 ng mL(-1) for bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol, respectively, were achieved under the optimized conditions.

Adsorption↗

Solid-phase extraction of several phthalate esters from environmental water samples on a column packed with polytetrafluoroethylene turnings.

A method for the determination of several phthalate esters in water samples using solid-phase extraction coupled to high-performance liquid chromatography was developed. A polytetrafluoroethylene turnings packed column was used as a SPE adsorbent material. The analytes were sorbed on polytetrafluoroethylene turnings, from which they were eluted by a small amount of acetonitrile, followed by a RP-HPLC-UV analysis. Detection limits (3sigma) of 4.7, 3.1, 3.6, 4.3, and 5.8 ng mL(-1) for di-n-butyl-phthalate, di-cyclohexyl-phthalate, di-n-octyl-phthalate, di-n-nonyl-phthalate and di-iso-decyl-phthalate, respectively, were achieved. Acceptable recovery results (92.1-127.5%) were obtained on five phthalate esters spiked samples.

Journal Article↗