Study of water properties in nanospace.

Here we report an anomalous behavior of water, especially its viscosity and hydrodynamic flow, in a nanometer-confined space. As a typical model of a nanometer-confined space, the nanopillar chip, which was developed for DNA size-based separation was used, and single-particle tracking (SPT) technique was applied to investigate water viscosity and hydrodynamic flow in the nanopillar chip. The diffusion coefficients of nanospheres were almost one-third of the theoretical value derived from the Stokes-Einstein equation. This result gave indirect proof that water viscosity in a nanometer-confined space is higher than in a bulk solution. In order to improve resolution and throughput of the nanopillar chip for DNA separation, these potential factors affecting performance should be seriously considered.

Journal Article↗

Two-dimensional multiarray formation of hepatocyte spheroids on a microfabricated PEG-brush surface.

A two-dimensional microarray of ten thousand (100 x 100) hepatocyte heterospheroids, underlaid with endothelial cells, was successfully constructed with 100 microm spacing in an active area of 20 x 20 mm on microfabricated glass substrates that were coated with poly(ethylene glycol) brushes. Cocultivation of hepatocytes with endothelial cells was essential to stabilize hepatocyte viability and liver-specific functions, allowing us to obtain hepatocyte spheroids with a diameter of 100 microm, functioning as a miniaturized liver to secret albumin for at least one month. The most important feature of this study is that these substrates are defined to provide an unprecedented control of substrate properties for modulating cell behavior, employing both surface engineering and synthetic polymer chemistry. The spheroid array constructed here is highly useful as a platform of tissue and cell-based biosensors and detects a wide variety of clinically, pharmacologically, and toxicologically active compounds through a cellular physiological response.

Animals↗

Separation of long DNA molecules by quartz nanopillar chips under a direct current electric field.

We have established the nanofabrication technique for constructing nanopillars with high aspect ratio (100-500 nm diameter and 500-5000 nm tall) inside a microchannel on a quartz chip. The size of pillars and the spacing between pillars are designed as a DNA sieving matrix for optimal analysis of large DNA fragments over a few kilobase pairs (kbp). A chip with nanopillar channel and simple cross injector was developed based on the optimal design and applied to the separation of DNA fragments (1-38 kbp) and large DNA fragments (lambda DNA, 48.5 kbp; T4 DNA, 165.6 kbp) that are difficult to separate on conventional gel electrophoresis and capillary electrophoresis without a pulsed-field technique. DNA fragments ranging from 1 to 38 kbp were separated as clear bands, and furthermore, the mixture of lambda DNA and T4 DNA was successfully separated by a 380-microm-long nanopillar channel within only 10 s even under a direct current (dc) electric field. Theoretical plate number N of the channel (380-1450 microm long) was 1000-3000 (0.7 x 10(6)-2.1 x 10(6) plates/m). A single DNA molecule observation during electrophoresis in a nanopillar channel revealed that the optimal nanopillars induced T4 DNA to form a narrow U-shaped conformation during electrophoresis whereas lambda DNA kept a rather spherical conformation. We demonstrated that, even under a dc electric field, the optimal nanopillar dimensions depend on a gyration radius of DNA molecule that made it possible to separate large DNA fragments in a short time.

DNA↗

Low-voltage electroosmosis pump for stand-alone microfluidics devices.

Two types of low-voltage electroosmosis pumps were developed using microfabrication technology for usage in handy or stand-alone applications of the micrototal analysis systems (micro-TAS) and the lab-on-a-chip. This was done by making a thin (< 1 microm) region in the flow path and by only applying voltages near this thin region using electrodes inserted into the flow path. The inserted electrodes must be free from bubble formation and be gas-tight in order to avoid pressure leakage. For these electrodes, Ag/AgCl or a gel salt bridge was used. For patterning the gel on the chip, a hydrophilic photopolymerization gel and a photolithographic technique were optimized for producing a gel with higher electric conductivity and higher mechanical strength. For high flow rate application, wide (33.2 mm) and thin (400 nm) pumping channels were compacted into a 1 mm x 6 mm area by folding. This pump achieves an 800 Pa static pressure and a flow of 415 nL/min at 10 V. For high-pressure application, a pump was designed with the thin and thick regions in series and positive and negative electrodes were inserted between them alternatively. This pump could increase the pumping pressure without increasing the supply voltage. A pump with 10-stage connections generated a pressure of 25 kPa at 10 V.

Acrylic Resins↗

Immunoelectrophoresis of red blood cells performed on microcapillary chips.

Immunoanalysis of blood cells on a microcapillary electrophoresis (nuCE) chip has been studied using sheep erythrocytes (ShE) as an example. Two different buffer solutions, the phosphate-buffered saline (PBS) and the gelatin veronal buffer (GVB) were examined in regard to the electrokinetic transport behavior of ShE suspended in these solutions inside the rectangular channel engraved on a quartz chip. This clarified two advantages of the use of GVB for on-chip cell electrophoresis: gelatin coatings prevent (i) nonspecific sticking of ShE on the channel wall, and cause (ii) an appreciable reduction in the zeta potential of the wall suppressing the electroosmotic flow of the buffer solution. As a result ShE suspended in the GVB can smoothly migrate from the cathode to the anode, which is the opposite flow direction of immunoglobulin G (IgG) antibodies under the physiological pH condition of 7.4. Based on these results, on-chip capillary cell immunoelectrophoresis of ShE and rabbit anti ShE antibodies (IgG) have been proposed and successfully accomplished using the GVB. It is demonstrated that the variation of the cell migration velocity originating from the change in the surface charge after binding antibodies is applicable to the fast detection of immune reactions and also to single-cell typing.

Animals↗

Investigation of the possibility of geometrical electrophoresis.

We investigate the possibility of geometrical electrophoresis, which is based on nanofabrication techniques. (GEE) utilizes geometrical effects during electrophoresis, which are generated by physical interactions between walls and a macromolecule confined in spaces smaller than the Flory radius. When a polymer is injected into a small space, confinement energy is usually required. However, the confinement energy form depends on the geometry of the space. In the case of electrophoresis, the electric field itself changes depending on the geometry. Using a nanofabricated quartz chip with a curved channel, we investigated electrophoretic behavior of high molecular weight DNA based on the curvature effect.

DNA↗

pH Change of buffer solution in a microcapillary chip and its suppression.

During the electrophoresis separation of B- and T-cells from lymphocytes employing a microcapillary chip, they were found to become inactive in the reservoir after a short time. This was caused by the buffer solution becoming alkaline due to electrolysis. This was considered to take place in chips with small reservoir volumes. The pH change was confirmed by the ISFET (ion-sensitive field effect transistor) embedded in the chip. To suppress the pH change, two methods were studied. One is the insertion of a salt bridge just in front of and behind the capillary, thus introducing an electric potential but stopping flow of the acid and alkaline solutions into the capillary. The other is neutralization of the alkaline solution in the reservoir by injecting the acid solution produced in another capillary with the same structure by employing an electroosmotic flow (EOF) pump. Both methods achieved no pH change during electrophoresis measurements in the microcapillary.

Animals↗