Is the time for absorption and oxidation of 13c-octanoate really negligible in the gastric emptying breath test?
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Yasushi Kuyama.
Explore the source record for details and available documents.
A urinary test for detecting the anti-H. pylori antibody using immunochromatography (RAPIRAN) is considered suitable for the screening purpose. However, this may yield spurious results in the presence of proteinuria. The present study was conducted to evaluate the diagnostic performance of RAPIRAN in patients with proteinuria. Urine and serum samples of adult inpatients with proteinuria were used for analyses. The diagnosis of H. pylori infection was made based on the seropositivity of anti-H. pylori antibody using 2 different serum tests. Fifty-one subjects were eligible for analyses. The serum tests showed negative and positive in 25 and 26 patients, respectively. Two of 25 seropositive patients had a negative result in RAPIRAN, and 1 provided invalid data. All of seronegative patients showed negative in RAPIRAN. The overall accuracy was 95.0%. The present study showed that RAPIRAN has diagnostic quality enough to use clinically also in patients with proteinuria.
Explore the source record for details and available documents.
BACKGROUND: The dynamic change in gastric emptying on a minute-by-minute basis (gastric velocity) is evaluated by the 13C-octanoate breath test with deconvolution analysis. However, deconvolution is impractical, because it requires dual experiments to obtain 13CO2 excretion profiles following intraduodenal and oral administration of 13C-octanoate. We investigated whether the Wagner-Nelson method, used in drug absorption studies, can determine the velocity profile based on a single experiment as accurately as deconvolution, and whether the velocity assessed by the Wagner-Nelson method is sensitive enough to detect subtle changes in gastric emptying induced by butylscopolamine. METHODS: Five male volunteers underwent a 4-h breath test twice, after intraduodenal administration of 20 ml normal saline containing 100 mg 13C-octanoate and after ingestion of a 320-kcal muffin containing 100 mg 13C-octanoate. Deconvolution determined the velocity profile by subtracting duodenal from oral data, and the Wagner-Nelson method produced it from only oral data. The velocity profiles were compared between the two methods. Another six male subjects underwent the breath test by ingesting a muffin twice, once with and once without 20 mg oral butylscopolamine. The velocity profiles generated by the Wagner-Nelson analysis and the conventional 13CO2 excretion curves were compared between the two occasions. RESULTS: The two techniques yielded identical velocity profiles. The velocity profile detected a significant change in the emptying pattern induced by butylscopolamine (initial acceleration with subsequent deceleration), while the conventional breath curves failed to detect this change. CONCLUSIONS: Velocity assessment by a Wagner-Nelson analysis can precisely describe altered gastric emptying, based on a single experiment.
Explore the source record for details and available documents.
1. The [(13)C]-acetate breath test (ABT) quantifies gastric emptying as the half [(13)CO(2)]-excretion time (T(1/2b)), but T(1/2b) differs from the scintigraphic half-emptying time (T(1/2s)). The aims of the present study were to accurately determine the half-emptying time by ABT with Wagner-Nelson analysis (T(1/2WN)), to compare T(1/2WN) with T(1/2s) and to validate the Wagner-Nelson strategy in ABT. 2. For a comparative study, eight volunteers simultaneously underwent ABT and scintigraphy. Anterior images were acquired and breath samples were collected every 15 min for 4.0 h after ingestion of a 200 kcal liquid meal labelled with 37 MBq [(99m)Tc]-colloidal sulphur and 100 mg [(13)C]-acetate. For the validation experiment, another six volunteers underwent ABT, on two randomized occasions, using the 200 kcal liquid meal with 100 mg [(13)C]-acetate. On either of the two occasions, a gel-forming agent was stirred into the meal to intentionally delay gastric emptying by increasing meal viscosity. Breath samples were collected at regular 15 min intervals for 4 h post ingestion. 3. The Wagner-Nelson equation for ABT is F(t) = (A(breath)(t) + C(t)/0.65)/A(breath)(infinity), where F(t) is a fractional dose of the [(13)C] label emptied, C(t) is the [(13)CO(2)] excretion (% dose/h), A(breath)(t) is the area under the C(t) curve (% dose) and A(breath)(infinity) is the ultimate [(13)CO(2)] recovery in breath (% dose). The percentage gastric retention was estimated as 100 x (1 - F(t)). The time plots of scintigraphic activity and 100 x (1 - F(t)) were fitted to y(t) = 100 x e(-Kxt), K values were estimated mathematically for each plot by regression analysis and T(1/2s) and T(1/2WN) were calculated as (ln2)/K. The time versus pulmonary [(13)CO(2)] excretion plots were fitted to z(t) = m x k x beta x e(-kt)(1 - e(-kxt))(beta-1), where m, k and beta are constants; T(1/2b) was calculated as -(ln(1 - 2(-1/beta))]/k. 4. Values of T(1/2WN) were closer to T(1/2s) than T(1/2b), although T(1/2WN) and T(1/2b) yielded significant under- and overestimation of T(1/2s), respectively. The high viscosity meal significantly prolonged T(1/2WN) and T(1/2b); T(1/2WN) could detect the delayed transit of the viscous meal more sensitively than T(1/2b). 5. The Wagner-Nelson method improves the accuracy of the ABT.
BACKGROUND/AIMS: Knowledge is limited regarding the effects of rabeprazole on gastric emptying. This randomized, open, crossover study was undertaken to investigate the effects. METHODS: In 24 healthy volunteers (13 men and 11 women, aged 22-53 years), solid emptying was assessed twice using the 13C-octanoate breath test. On one occasion, the subjects received 20 mg rabeprazole for the preceding 2 days and 1 h before the test. On another occasion, they underwent no pretreatment. The time course of cumulative recovery of 13CO2 in breath was fitted to z(t)=m(1-e-kt)beta-1, and regression constants of k and beta were determined. The half 13CO2 excretion time (t(1/2)b)) and the time of maximal excretion (tmax) were calculated. Under the crossover protocol, k and beta can describe the emptying features more precisely; a larger (smaller) beta indicates a slower (faster) emptying in the early phase, and a larger (smaller) k indicates a faster (slower) emptying in the later phase. Between the two occasions, k, beta, t(1/2)b, and tmax were compared. RESULTS: Rabeprazole significantly decreased k and beta, significantly prolonged t(1/2)b, but tmax remained unchanged. CONCLUSION: Rabeprazole has dual effects on solid emptying: an initial acceleration with a subsequent deceleration, resulting in an overall delay.
AIM: Although the quality of currently available urinary tests for detecting antibody to Helicobacter pylori (H pylori) have been proved in some populations, the accuracy has not been studied regarding patients who suffer from pulmonary tuberculosis with multi-drug treatments. The present study was conducted to evaluate the accuracy of these urinary tests for antibody to H pylori in these patients. METHODS: Serum samples from 61 inpatients with pulmonary tuberculosis were tested using enzyme immunoassay, and urine samples were assayed by enzyme-linked immunosorbent assay method (URINELISA) and immunochromatography method (RAPIRAN). Medicines prescribed to the patients were recorded for medical charts, to evaluate the influences on the results of urinary tests. RESULTS: The sensitivity, specificity, and consistency of URINELISA against the serum test were 93.1%, 65.6%, and 78.6% respectively, and those of RAPIRAN were 86.2%, 93.7%, and 90.1% respectively, which were almost equal to the data previously reported. Prescribed medicines had little influence on the results. CONCLUSION: The two urinary tests for detecting H pylori antibody have a diagnostic accuracy in patients with pulmonary tuberculosis given multiple anti-tuberculosis drugs.
BACKGROUND: Cigarette smoking is associated with an increased risk of peptic ulcer and gastroesophageal reflux disease. Gastric emptying disorders may play a role in the development of these upper gastrointestinal diseases. Thus, studies examining a link between smoking and gastric emptying disorders have clinical relevance. This study was conducted to investigate the effect of smoking on gastric emptying of solids in Japanese smokers. METHODS: The (13)C-octanoic acid breath test was performed in eight male habitual smokers on two randomized occasions (either sham smoking or actively smoking). The time vs (13)CO(2) excretion rate curve was mathematically fitted to a conventional formula of y (t) = m*k*beta*e(-k*t)*(1 - e(-k*t))(beta-1), and the parameters of k and beta were determined: under the crossover protocol, a larger (smaller) beta indicates slower (faster) emptying in the early phase, and a larger (smaller) k indicates faster (slower) emptying in the later phase. The half (13)CO(2) excretion time (t(1/2b) = -[ln(1 - 2(-1/beta))]/k) and the time of maximal (13)CO(2) excretion rate (t(max) = [lnbeta]/k) were also calculated. Between the two occasions, k, beta, t(1/2b), and t(max) were compared by the Wilcoxon signed-rank test. RESULTS: After smoking, k was significantly increased. No significant differences were found in beta, t(1/2), and t(max) between the two occasions. CONCLUSIONS: The increase in k suggests the acceleration of gastric emptying in the later phase. For the first time, this study has revealed that acute smoking speeds the gastric emptying of solids in Japanese habitual smokers.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
1. In the [(13)C]-octanoic acid breath test, the time versus pulmonary [(13)CO(2)] excretion rate curve is analysed using mathematical curve-fitting techniques to calculate gastric emptying parameters. Thus, the goodness-of-fit highly influences the accuracy of the breath test. However, a double-peaked [(13)CO(2)] excretion curve, which occasionally develops owing to the presence of an interval of quiescent gastric emptying (the plateau phase), is likely to be fitted poorly. 2. In pharmacokinetics, the Wagner-Nelson method has been used to describe precisely the absorption kinetics of orally administered drugs and its reliability is independent of the nature of gastric emptying. A recent study has shown the potential of the Wagner-Nelson method to generate a realistic gastric emptying flow curve from [(13)CO(2)] excretion data. In the present report, we have demonstrated that the Wagner-Nelson method can visualize the plateau emptying phase responsible for the cases of double peaks. 3. Wagner-Nelson analysis applied to the breath test described precisely the characteristic emptying pattern of the two emptying phases being interrupted by the plateau phase. Conventional analysis for the breath test failed to detect the plateau phase. 4. The Wagner-Nelson method is a useful tool for analysing atypical double-peaking [(13)CO(2)] excretion curves.
BACKGROUND: In pharmacokinetics, the Wagner-Nelson (W-N) method can accurately estimate the rate of drug absorption from its urinary elimination rate. A stable isotope (13C) breath test attempts to estimate the rate of absorption of 13C, as an index of gastric emptying rate, from the rate of pulmonary elimination of 13CO2. The time-gastric emptying curve determined by the breath test is quite different from that determined by scintigraphy or ultrasonography. In this report, we have shown that the W-N method can adjust the difference. METHODS: The W-N equation to estimate gastric emptying from breath data is as follows: the fractional cumulative amount of gastric contents emptied by time t = Abreath (t)/Abreath (infinity) + (1/0.65).d[Abreath (t)/Abreath (infinity) ]/dt, where Abreath (t) = the cumulative recovery of 13CO2 in breath by time t and Abreath ( infinity ) = the ultimate cumulative 13CO2 recovery. The emptying flow curve generated by ultrasonography was compared with that generated by the W-N method-adjusted breath test in 6 volunteers. RESULTS: The emptying curves by the W-N method were almost identical to those by ultrasound. CONCLUSIONS: The W-N method can generate an accurate emptying flow curve from 13CO2 data, and it can adjust the difference between ultrasonography and the breath test.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In recent years, the C-octanoate breath test has attracted attention as a simple and noninvasive method of assessing gastric emptying of solids. However, practical procedures for test meals, parameters used, and sampling points have not yet been established. Moving toward a more convenient method, here we examined the influences of sampling interval and duration on the C-octanoate breath test performed on 15 healthy subjects using a commercially-available instant cupcake. Breath samples were obtained every 15 minutes within 4 hours, and every 30 minutes in the subsequent 2 hours. Using computer simulation, the time it took for the fitting curve to peak (Tpeak) was calculated in each setting with each interval (15, 30, 60, and 120 minutes) and test duration (3, 4, 5, and 6 hours). When the sampling interval widened over 30 minutes, the difference from the original 6-hour data became larger than 20% of the coefficient of variance. When the sampling duration was shortened to 3 hours, no appropriate fitting curve could be achieved. These results suggest that a sampling duration of 4 hours at 30-minute intervals seems to be suitable for practical use of the test.