PubMed Health⌕ Search

Biomedical subjects

Yatin Mehta

Publications and source records attributed to Yatin Mehta.

At least 19 recordsLinked to original sources

Device-associated nosocomial infections in 55 intensive care units of 8 developing countries.

BACKGROUND: Health care-associated infections from invasive medical devices in the intensive care unit (ICU) are a major threat to patient safety. Most published studies of ICU-acquired infections have come from industrialized western countries. In a Centers for Disease Control and Prevention (CDC) National Nosocomial Infections Surveillance (NNIS) System report, the U.S. pooled mean rates of central venous catheter (CVC)-related bloodstream infections, ventilator-associated pneumonia, and catheter-associated urinary tract infections were 4.0 per 1000 CVC days, 5.4 per 1000 mechanical ventilator days, and 3.9 per Foley catheter days, respectively. OBJECTIVE: To ascertain the incidence of device-associated infections in the ICUs of developing countries. DESIGN: Multicenter, prospective cohort surveillance of device-associated infection by using the CDC NNIS System definitions. SETTING: 55 ICUs of 46 hospitals in Argentina, Brazil, Colombia, India, Mexico, Morocco, Peru, and Turkey that are members of the International Nosocomial Infection Control Consortium (INICC). MEASUREMENTS: Rates of device-associated infection per 100 patients and per 1000 device days. RESULTS: During 2002-2005, 21,069 patients who were hospitalized in ICUs for an aggregate 137,740 days acquired 3095 device-associated infections for an overall rate of 14.7% or 22.5 infections per 1000 ICU days. Ventilator-associated pneumonia posed the greatest risk (41% of all device-associated infections or 24.1 cases [range, 10.0 to 52.7 cases] per 1000 ventilator days), followed by CVC-related bloodstream infections (30% of all device-associated infections or 12.5 cases [range, 7.8 to 18.5 cases] per 1000 catheter days) and catheter-associated urinary tract infections (29% of all device-associated infections or 8.9 cases [range, 1.7 to 12.8 cases] per 1000 catheter days). Notably, 84% of Staphylococcus aureus infections were caused by methicillin-resistant strains, 51% of Enterobacteriaceae isolates were resistant to ceftriaxone, and 59% of Pseudomonas aeruginosa isolates were resistant to fluoroquinolones. The crude mortality rate for patients with device-associated infections ranged from 35.2% (for CVC-associated bloodstream infection) to 44.9% (for ventilator-associated pneumonia). LIMITATIONS: These initial data are not adequate to represent any entire country, and likely variations in the efficiency of surveillance and institutional resources may have affected the rates that were detected. CONCLUSIONS: Device-associated infections in the ICUs of these developing countries pose greater threats to patient safety than in U.S. ICUs. Active infection control programs that perform surveillance of infection and implement guidelines for prevention can improve patient safety and must become a priority in every country.

Catheterization, Central Venous↗

Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery.

OBJECTIVE: To compare cardiac output (CO), stroke volume (SV), and cardiac index (CI) as estimated with a new, noninvasive Doppler device (Ultrasonic Cardiac Output Monitor [USCOM]; USCOM Ltd, Sydney, Australia) with those measured with the bolus thermodilution (TD) technique. DESIGN: Prospective nonrandomized study. SETTING: Postcardiac surgery recovery unit of a tertiary cardiac center. PARTICIPANTS: Fifty patients after off-pump coronary artery bypass (OPCAB) surgery. MEASUREMENT AND MAIN RESULTS: Both right-sided and left-sided CO were estimated with a USCOM continuous-wave (CW) Doppler device, and CO was determined with the bolus TD technique performed in triplicate. On comparing the right-sided CO, SV, and CI with those of TD, the mean bias was 0.03 L/min, 1.6 mL, and 0.02 L/min/m(2), respectively. The comparison of left-sided CO, SV, and CI with those of TD revealed a means bias of 0.14 L/min, 1.0 mL, and 0.08 L/min/m(2), respectively. CONCLUSION: This study showed excellent agreement between the values for CO, SV, and CI as determined with USCOM and TD. Since there was only 1 time period for CO estimation in each patient with both methods, the stability of this correlation needs to be further investigated over time.

Adult↗

Ascending aortic aneurysm resection: 15 years' experience.

Between September 1989 and June 2004, 148 consecutive patients underwent ascending aortic replacement for aneurysm or dissection. There were 130 males (88%) and 18 females (12%). Their mean age was 46.20 +/- 13.36 years. Fifty-seven patients (39%) were treated for type 1 and type 2 aortic dissection, and 91 (61%) for ascending aortic aneurysm. The Bentall procedure was performed in 81 patients (55%), the Cabrol procedure in 7 (5%), separate ascending aortic replacement and aortic valve replacement or repair was carried out in 24 (16%), and ascending aortic replacement only in 36 (24%). Hospital mortality was 4.05% (6 deaths). On univariate analysis, left ventricular ejection fraction < or = 30%, emergency surgery, contained rupture, concomitant coronary artery bypass grafting, and age > or = 65 years were risk factors for early mortality. However, on multivariate analysis, ejection fraction < or = 30% and contained rupture were the only factors significantly associated with early mortality. The long-term survival rates were 87.2% +/- 3.7% at 5 years, 78.0% +/- 5.6% at 10 years, and 60.9% +/- 9.9% at 15 years. Ascending aortic resection for aneurysm or dissection can be performed with low mortality and morbidity.

Adult↗

Totally endoscopic coronary artery bypass surgery.

Robotically enhanced surgery is a fast-developing technique that allows totally endoscopic cardiac surgery on both the beating and arrested heart. Between December 2002 and May 2005, 13 patients underwent totally endoscopic coronary bypass using the da Vinci system; 11 operations were on a beating heart and 2 on arrested hearts. The mean time for internal mammary artery mobilization was 42 min. The time for left internal mammary artery-to-left anterior descending artery anastomosis was 20-36 min for totally endoscopic cases. In one patient, the right internal mammary artery was anastomosed to the diagonal artery. No patient required conversion to a median sternotomy. Mean intensive care unit stay was 1.2 days and mean hospital stay was 4.5 days. There was no hospital mortality. All 13 patients had coronary angiography at 3-month intervals, which showed 100% patency in 12 patients while one had 50% anastomotic narrowing for which coronary angioplasty was performed. Using robotic technology, completely endoscopic anastomosis is possible in patients with single-vessel disease. Use of robotics is now extended to achieve complete myocardial revascularization by harvesting both internal mammary arteries in addition to making a small thoracotomy for direct anastomosis.

Adult↗

Elevated troponin level is not synonymous with myocardial infarction.

BACKGROUND: Elevated troponin I in the absence of angiographically visible coronary lesions is seen in up to 10-15% of those undergoing angiography for suspected coronary artery disease. This study aims to elucidate the etiology of elevated cardiac troponin I in patients with normal coronary arteries on angiography. METHODS: We identified 1551 (8.6%) patients with normal coronary arteries from our catheterization database of 17,950 patients from Jan 2000 to Jun 2004. Elevated troponin I levels were found in 217 (14%) of 1551 patients with normal coronary arteries. Of these 217 patients, 73 surgical patients were excluded, and the remaining 144 patients formed the study population. The study population was compared with age and gender matched patients with myocardial infarction and coronary artery disease (Group II). RESULTS: The patients with elevated cardiac troponin I (cTnI) with normal coronary arteries had significantly lower prevalence of atherosclerotic risk factors and significantly higher left ventricular ejection fractions. The cTnI in patients with normal coronary arteries was elevated due to a number of causes including tachycardia, myocarditis, pericarditis, severe aortic stenosis, gastrointestinal bleeding, sepsis, left ventricular hypertrophy, severe congestive heart failure, cerebrovascular accident, electrical trauma, myocardial contusion, hypertensive emergency, myocardial bridging, pulmonary embolism, diabetic ketoacidosis, chronic obstructive pulmonary disease exacerbation and coronary spasm. CONCLUSIONS: Cardiac troponin I could be elevated in a number of conditions, apart from acute myocardial infarction, and could reflect myonecrosis. Acute myocardial infarction is a clinical diagnosis as the laboratory is an aide to, not a replacement for, informed decision making.

Aged↗

Hemodynamic measurements after cardiac surgery: transesophageal Doppler versus pulmonary artery catheter.

OBJECTIVE: The purpose of this study was to compare hemodynamic data derived from the transesophageal Doppler monitor (Medicina TECO, Berkshire, United Kingdom) against those obtained from a pulmonary artery catheter after coronary artery bypass grafting (CABG). DESIGN: Prospective, nonrandomized, clinical study. SETTING: Single, tertiary referral center. PARTICIPANTS: Thirty-five adult patients. INTERVENTIONS: Cardiac output and hemodynamic variables were measured and compared at 4 predefined time points in patients undergoing elective off-pump CABG surgery from January 2003 through June 2003. MEASUREMENT AND MAIN RESULTS: A total of 140 pairs for cardiac output (CO) data were obtained. Transesophageal cardiac output (TECO) values ranged from 1.9 to 8.7 L/min. Thermodilution cardiac output (TDCO) values ranged from 2.7 to 7.6 L/min. Matched measurements were made with each patient at intervals of 30 minutes. Bland-Altman analysis revealed a mean bias of 1.18 +/- 1.36 L/min, with a correlation (r) of 0.593 (p < 0.000) between TECO and TDCO. Similarly poor correlation was observed among cardiac index (r = 0.523), stroke volume (r = 0.615), systemic vascular resistance (r = 0.595), left ventricular stroke work index (r = 0.594), and right ventricular stroke work index (r = 0.590) measured by an esophageal Doppler monitor against a pulmonary artery catheter. CONCLUSION: A transesophageal Doppler device (Medicina TECO) cannot be relied on as a sole method for monitoring cardiac output and derived hemodynamic variables in patients after CABG surgery.

Aged↗

Mitral valve repair for ischemic mitral regurgitation in dilated cardiomyopathy.

Ischemic mitral regurgitation contributes to poor survival in patients with heart failure. The intermediate-term outcome of mitral reconstruction in 15 patients who had ischemic dilated cardiomyopathy with mitral regurgitation requiring surgical intervention was studied. They underwent mitral valve repair along with coronary artery bypass surgery. The mitral valve coaptation depth was considered an important parameter in deciding on repair. Ages ranged from 43 to 72 years. Left ventricular ejection fractions were 15-38% (mean, 26.5% +/- 4.3%). The operative technique in all 15 patients was posterior annuloplasty using Dacron felt. At a mean follow-up of 4.6 +/- 1.2 months (1-8 months), postoperative transesophageal echocardiography revealed mild mitral regurgitation in 2 patients and none in 13. There was a significant improvement in New York Heart Association functional class from 3.9 +/- 1.1 to 1.9 +/- 0.3. Mitral valve repair by posterior felt annuloplasty provides favorable results in the intermediate-term in selected patients with ischemic cardiomyopathy and severe left ventricular dysfunction.

Adult↗

Nosocomial infections and balloon counterpulsation: risk factors and outcome.

Between February and September 2003, 136 (5.3%) of 2,558 patients undergoing cardiac surgery were supported with intra-aortic balloon counterpulsation. There were 71 infected (group 1) and 65 noninfected (group 2) patients. Risk factors for nosocomial infections were identified by univariate and multivariate analysis. On univariate analysis, significant risk factors were operation time, balloon pump duration, ventilation hours, duration of central venous catheter placement, amount of blood transfused, left ventricular ejection fraction<30%, intra- and/or postoperative intra-aortic balloon counterpulsation, surgery under cardiopulmonary bypass, combined procedures, re-exploration, and Acute Physiology And Chronic Health Evaluation (APACHE) II score. On multivariate analysis, ventilation hours and amount of blood transfused were independently associated with group 1. Respiratory tract infections were common in the balloon counterpulsation population (41.1%). Mortality was significantly higher in patients needing balloon pump support (19.9%) compared to controls (1.1%), but it was similar in groups 1 and 2. Recognition of risk factors for postoperative infection in patients undergoing cardiovascular surgical procedures with intra-aortic balloon counterpulsation may help to improve their prognosis and allow more organized surveillance.

Aged↗

Site-specific detection of bleeder using transesophageal echocardiography.

Transesophageal echocardiography continues to be an indispensable postoperative diagnostic tool for cardiac surgical patients. Transesophageal echocardiography was carried out postoperatively in 30 consecutive hypotensive patients with low cardiac output who had undergone coronary bypass surgery. In 19 of these patients, a cause of low cardiac output requiring surgical intervention was excluded, and they were managed conservatively. In 11 patients, a surgical cause of low cardiac output was indicated: diffuse bleeding from no particular site in 5, and from a specific site in 6. They underwent urgent re-operation, and the echocardiography findings were confirmed on the operating table. Not only is transesophageal echocardiography important in diagnosis, but it is also highly specific in locating the site of bleeding.

Adult↗

Concomitant carotid endarterectomy and coronary bypass surgery: outcome of on-pump and off-pump techniques.

BACKGROUND: There continues to be a dilemma regarding the best means of surgical management of significant carotid artery disease in patients requiring coronary artery bypass surgery. A combined approach of coronary artery bypass and carotid endarterectomy has shown good results in patients with concomitant carotid and coronary artery disease. We reviewed our results of coronary artery surgery using conventional cardiopulmonary bypass or off-pump techniques and carotid endarterectomy done as a combined procedure. METHODS: Between January 1996 and June 2002, 358 patients underwent concomitant coronary artery bypass and carotid endarterectomy. There were 140 males (84.3%) and 26 females (15.7%) in group I. Group II consisted of 158 males (82.3%) and 34 females (17.7%). One hundred sixty-six patients (group I) were done off pump whereas in 192 patients (group II), the procedure was done using conventional cardiopulmonary bypass. Carotid endarterectomy was performed before coronary artery bypass surgery in both groups. RESULTS: The average number of grafts were 3.4 +/- 0.8 with average operative time of 4.2 +/- 0.4 hours in group I, and 3.3 +/- 0.8 graft with operative time of 5.3 +/- 1.2 hours in group II (p = 0.239 and p < 0.001, respectively). There were 2 deaths (1.2%) in group I and 3 deaths (1.6%) in group II (p = 0.870). No patient from group I and 1 patient (0.5%) from group II had postoperative stroke (p = 0.941). Mean hospital stay was 9.0 +/- 1.2 days in group I and 11.2 +/- 1.7 days in group II (p < 0.001). At mean follow-up of 2.8 +/- 0.9 years in group I, 2 patients (1.2%) had late death due to cardiac failure and contralateral carotid endarterectomy was done in 2 patients (1.2%). Group II had mean follow-up of 2.4 +/- 0.6 years, during which 4 patients (2.1%) had late death and contralateral carotid endarterectomy was done in 3 patients (1.6%). Late stroke was seen in 1 patient (0.6%) from group I and 2 patients (1.0%) from group II. CONCLUSIONS: Concomitant carotid endarterectomy and coronary artery bypass is a safe and effective procedure in patients with significant coronary and carotid artery disease. Equally good results can be reproduced using cardiopulmonary bypass or off-pump techniques for coronary artery surgery, with low morbidity, mortality, and good long-term results.

Aged↗

Central venous catheter-related blood stream infections: incidence, risk factors, outcome, and associated pathogens.

OBJECTIVE: To determine the incidence, risk factors, outcome, and pathogens of central venous catheter-related bloodstream infections (CVC-BSIs). DESIGN: Prospective study. SETTING: Escorts Heart Institute and Research Centre, New Delhi, India. PARTICIPANTS: One thousand three hundred fourteen consecutive patients undergoing cardiac operations who were admitted to the intensive care unit with CVC. INTERVENTIONS: All patients were assigned into CVC-BSI (n = 35) and non-CVC-BSI (n = 1,279) groups. MEASUREMENT AND MAIN RESULTS: Of the 1,314 patients in the study, 35 (2.6%) had CVC-BSI. On univariate analysis, significant risk factors were use of multilumen catheters, coexistent infections, intra-aortic balloon counterpulsation (IABC), total ventilation hours, emergency surgery, acute physiology, age, chronic health evaluation score (APACHE II), and steroids. On multivariate analysis, duration of catheterization (24.5 +/- 10.9 v 6.1 +/- 3.2; p < 0.001), coexistent infections (57.11% v 2.61%; p < 0.001), IABC (77.1% v 4.1%; p = 0.005), and temperature (38.2 +/- 0.6 v 37.4 +/- 0.3; p < 0.001) were independent predictors of CVC-BSI. Pathogens isolated were Escherichia coli (47%), Acinetobacter species (11.7%), Enterobacter species (5.8%), Proteus species (5.8%), methicillin-resistant Staphylococcus species (11.7%), coagulase-negative Staphylococcus species (5.8%), and Candida (11.7%). The mortality rate in CVC-BSI was 22.9% as compared with 0.2% in non-CVC-BSI cases (p < 0.001). CONCLUSION: By univariate analysis, the risk factors for CVC-BSI were use of multilumen catheters, duration of catheterization, total ventilation hours, IABC, emergency surgery, APACHE II score, coexistent infections, and steroids. On multivariate analysis, duration of catheterization, IABC, coexistent infections, and temperature were independent predictors of CVC-BSI. The mortality was increased with CVC-BSI.

Bacteremia↗

Spinal (subarachnoid) morphine for off-pump coronary artery bypass surgery.

OBJECTIVE: To study the effects of 8 microg/kg preoperatively administered intrathecal morphine sulfate on extubation time, postoperative pulmonary function, and postoperative analgesia after off-pump coronary artery bypass grafting (OPCAB). DESIGN: A prospective, randomized, double-blind, placebo controlled study. PARTICIPANTS: One hundred adult patients scheduled for elective primary OPCAB. INTERVENTIONS: Patients were randomized to preoperative administration of 8 microg/kg intrathecal morphine sulfate (group 1) with a 25-gauge spinal needle or to receive sterile normal saline placebo subcutaneously (group 2). Anesthetic induction and maintenance were standardized to allow planning for facilitating early tracheal extubation. Multivessel OPCAB was performed with an Octopus stabilizer. Patients were extubated in the intensive care unit by a blinded observer using predefined extubation criteria. MEASUREMENTS AND MAIN RESULTS: Postoperative times to extubation were 9.47 +/- 3.83 hours in group 1 versus 11.25 +/- 3.94 hours in group 2 (P = .025). Postextubation bedside spirometric lung volumes in percentage of preoperative lung volume showed significant differences in group 1 versus group 2 in forced vital capacity, 39.66% +/- 15.42% versus 31.85% +/- 11.65% (P = .016); forced expiratory volume in the first second, 44.8% +/- 16.18% versus 35.97% +/- 13.32% (P = .013); maximum voluntary ventilation, 39.40% +/- 13.57% versus 33.11% +/- 14.80% (P = .056); and expiratory flow rate, 47.76% +/- 24.61% versus 37.37% +/- 4.33% (P = .031). The visual analog pain scores at rest and during coughing at time intervals of 6, 12, 24, and 36 hours postoperatively showed significantly better results in group 1 compared with group 2. The total dose of fentanyl citrate required intraoperatively was significantly less in group 1 (P = .00). One patient in group 1 had a low respiratory rate, which responded to injection naloxone. There was no mortality or neurological complication in either group. CONCLUSION: Intrathecal morphine provided superior quality of analgesia that translated into better maintenance of postoperative lung volume determined by spirometry. This analgesic method also facilitated earlier tracheal extubation without any major respiratory or neurologic complications.

Analgesics, Opioid↗

Ventilator-associated pneumonia: Incidence, risk factors, outcome, and microbiology.

OBJECTIVE: To determine the incidence, risk factors, outcome, and pathogens of ventilator-associated pneumonia (VAP) in a cardiac surgical intensive care unit (ICU). DESIGN: Prospective study. SETTING: Escorts Heart Institute and Research Centre, New Delhi, India. PARTICIPANTS: Nine hundred fifty-two consecutive patients undergoing cardiac operations who received intermittent positive-pressure ventilation (IPPV). INTERVENTIONS: All patients were assigned into VAP (n = 25) and non-VAP (n = 927) groups. MEASUREMENTS AND MAIN RESULTS: Risk factors and other variables were analyzed with univariate and multivariate analysis. Of the 952 patients studied, 25 (2.6%) had VAP. On univariate analysis, significant risk factors were emergency surgery, chronic obstructive pulmonary disease (COPD), reintubation, coma, steroid treatment, intra-aortic balloon counterpulsation (IABC), enteral feedings, tracheostomy, acute physiology, age, and chronic health evaluation (APACHE II) score, prior antibiotics, and IPPV hours. On multivariate analysis, IPPV hours (153.75 +/- 114.44 v 19.65 +/- 7.99; p < 0.001) and steroids (20% v 0%; p < 0.001) were independent predictors of VAP. The most common pathogens isolated were Pseudomonas aeruginosa (22), Escherichia coli (10), Klebsiella pneumoniae (4), Staphylococcus species (4), and Acinetobacter species (2). The mortality rate in VAP was 16% as compared with 0.2% in non-VAP cases (p < 0.001). CONCLUSION: These data suggest that by univariate analysis the risk factors for VAP were emergency surgery, COPD, reintubation, coma, steroid treatment, IABC, enteral feedings, tracheostomy, APACHE II score, prior antibiotics, and IPPV hours. On multivariate analysis, only IPPV hours and steroids were independent predictors of VAP. Pseudomonas aeruginosa is the most common pathogen associated with VAP, and the mortality is increased with VAP.

Cardiac Surgical Procedures↗

Multimodality targeted approach in redo off-pump coronary artery bypass surgery.

Records of 86 patients who underwent off-pump redo coronary revascularization between December 1997 and December 2000, were analyzed. Approaches included median sternotomy (47), anterolateral thoracotomy for left anterior descending artery and diagonal targets (35), posterolateral thoracotomy for the obtuse marginal with proximal anastomosis on descending aorta (3), and a combined subxiphoid-anterior thoracotomy approach (1) for right gastroepiploic artery-to-left anterior descending artery anastomosis. The mean age was 61.82 years. There were 2 (2.3%) operative deaths. Complications included perioperative myocardial infarction in 4 patients and reexploration for bleeding in one. Blood transfusion was required in 12 patients. The mean length of hospital stay was 5 +/- 2 days. A multimodality targeted approach for off-pump redo coronary artery bypass offers a less invasive but safer method of myocardial revascularization, with decreased complications, lower blood product requirement, and early hospital discharge.

Aged↗