PubMed Health⌕ Search

Biomedical subjects

Ye-xiang Zhu

Publications and source records attributed to Ye-xiang Zhu.

2 recordsLinked to original sources

Selective solid-phase extraction of bisphenol A using molecularly imprinted polymers and its application to biological and environmental samples.

Molecularly imprinted polymers (MIPs) were prepared using bisphenol A (BPA) as a template by precipitation polymerization. The polymer that had the highest binding selectivity and ability was used as solid-phase extraction (SPE) sorbents for direct extraction of BPA from different biological and environmental samples (human serum, pig urine, tap water and shrimp). The extraction protocol was optimized and the optimum conditions were as follows: conditioning with 5 mL methanol-acetic acid (3:1), 5 mL methanol, 5 mL acetonitrile and 5 mL water, respectively, loading with 5 mL aqueous samples, washing with 1 mL acetonitrile, and eluting with 3 mL methanol. MIPs can selectively recognize, effectively trap and preconcentrate BPA over a concentration range of 2-20 microM. Recoveries ranged from 94.03 to 105.3%, with a relative standard deviation lower than 7.9%. Under the optimal condition, molecularly imprinted SPE recoveries of spiked human serum, pig urine, tap water and shrimp were 65.80, 82.32, 76.00 and 75.97%, respectively, when aqueous samples were applied directly. Compared with C18 SPE, a better baseline, better high-performance liquid chromatography separation efficiency and higher recoveries were achieved after molecularly imprinted SPE.

Animals↗

Direct enrichment and high performance liquid chromatography analysis of ultra-trace Bisphenol A in water samples with narrowly dispersible Bisphenol A imprinted polymeric microspheres column.

Direct injection, enrichment and high performance liquid chromatography (HPLC) analysis of ultra-trace Bisphenol A (BPA) in water samples using one narrowly dispersible BPA imprinted polymeric microspheres (MIPM) column in one analysis process was developed. One BPA imprinted MIPM that had the best globular morphology and imprinted efficiency was used as HPLC stationary phase and applied to direct analysis of ultra-trace BPA in water. The optimum direct analysis conditions were: conditioning the MIPM column with water for 10min, injecting 40mL water sample directly, eluting with 70% methanol for 13min and then 100% methanol for 7min. Under the optimum conditions, the MIPM column can simultaneously extract, enrich, separate and determine ultra-trace BPA in one analysis process with UV detector by injection of large volume water samples (40mL). The calibration graph was linear with R(2)>0.998 in the ranges from 0.1-100nmol/L BPA standard solution. The intra- and inter-day RSD are less than 9.5 and 9.6%, respectively. The limit of quantification was 0.1nmol/L. RSD for spiked tap and lake water was less than 8.9% and the recoveries were 96-101.8%. The enrichment factor for BPA was 10,000 as 40mL water sample was directly injected and analyzed.

Benzhydryl Compounds↗