PubMed Health⌕ Search

Biomedical subjects

Yen Sun

Publications and source records attributed to Yen Sun.

13 recordsLinked to original sources

Investigating mechanisms of collagen thermal denaturation by high resolution second-harmonic generation imaging.

We apply the technique of second-harmonic generation (SHG) microscopy to obtain large area submicron resolution image of Type I collagen from rat tail tendon as it is heated from 40 degrees C to 70 degrees C for 0-180 min. The change in the collagen structure as reflected in its SHG image is observed at length scales from submicron to hundreds of microns. We observed that heating the tendon below the temperature of 54 degrees C does not produce any change in the averaged SHG intensity. At the heating temperature of 54 degrees C and above, we find that increasing the heating temperature and time leads to decreasing SHG intensity. As the tendon is heated above 54 degrees C, the regions where the SHG signal vanish and form a tiger-tail like pattern. In addition, a decrease in the SHG signal occurs uniformly throughout the tendon. By comparing the relative SHG intensities in small and large areas, we found that the denaturation process responsible for forming the tiger-tail like pattern occurs at a higher rate than the global denaturation process occurring throughout the tendon. We also measured the fibril spacing and found that it remains constant at 1.61 +/- 0.04 micron for all heating temperature and times. The constant fibril density shows that the global denaturation process occurs at a length scale smaller than the size of the fibril. Our results show that second-harmonic generation microscopy is effective in monitoring the thermal damage to collagen and has potential applications in biomedicine.

Animals↗

Effects of different immersion media in multiphoton imaging of the epithelium and dermis of human skin.

In this work, we compared the performance of objectives with similar numerical aperture of 0.75 but different immersion media of air, water, glycerin, and oil in the imaging of human skin epithelium and dermis. In general, we found that the oil immersion objective recorded the strongest intensity at the same mechanical depth. We also characterized the focal shifts and found that with decreasing refractive index, the focal shift becomes increasingly more negative (for both the epithelium and dermis). In imaging the dermis, we estimated the image resolution at the depths of 18.8 and 30.2 microm, and found that the image resolution were comparable at these depths under the four types of immersion conditions. Our results demonstrate that by changing the immersion media, the main microscopic imaging effects are the recorded axial intensities and the focal shifts. The effects on the image resolution are negligible.

Dermis↗

Multiphoton autofluorescence and second-harmonic generation imaging of the ex vivo porcine eye.

PURPOSE: The purpose of this work was to demonstrate the use of the combined imaging modality of multiphoton autofluorescence and second-harmonic generation (SHG) microscopy in obtaining spectrally resolved morphologic features of the cornea, limbus, conjunctiva, and sclera in whole, ex vivo porcine eyes. METHODS: The 780-nm output of a femtosecond, titanium-sapphire laser was used to induce broadband autofluorescence (435-700 nm) and SHG (390 nm) from various regions of the surface of ex vivo porcine eyes. A water-immersion objective was used for convenient imaging of the curved surface of the eye. RESULTS: Multiphoton autofluorescence was useful in identifying cellular structures of the different domains of the ocular surface, and the SHG signal can be used to resolve collagen organization within the cornea stroma and sclera of ex vivo porcine eyes. CONCLUSIONS: Multiphoton autofluorescence and SHG microscopy have been demonstrated to be an effective technique for resolving, respectively, the cellular and collagen structures within the ocular surface of ex vivo porcine eyes. SHG imaging resolved the difference in structural orientations between corneal and sclera collagen fibers. Specifically, the corneal collagen is organized in a depth-dependent fashion, whereas the scleral collagen is randomly packed. Because this technique does not require histologic preparation procedures, it has the potential to be applied for in vivo studies with minimal disturbance to the eye.

Animals↗

Multiphoton fluorescence and second harmonic generation imaging of the structural alterations in keratoconus ex vivo.

PURPOSE: To demonstrate the application of multiphoton fluorescence (MF) and second harmonic generation (SHG) microscopy for ex vivo characterization of the structural alterations of human corneas due to keratoconus. METHODS: Buttons of keratoconic corneas derived from penetrating keratoplasty were sent for structural analysis with a custom-built multiphoton microscope. Fluorescence detected within the cytoplasm and the SHG signal obtained from collagen were used to demonstrate the morphologic changes in the corneal specimens. RESULTS: The fluorescent epithelial cells around the apical area were elongated and were aligned parallel to the adjacent collagen fibers. Parallel and centripetal distribution patterns of stromal collagen bundles were demonstrated at different depths within the keratoconic corneas. CONCLUSIONS: MF and SHG microscopy provides three-dimensional structural analysis of keratoconus ex vivo. It may provide important morphologic information for the investigation of the pathogenesis of keratoconus and may have potential in a clinical setting as an in vivo diagnostic and monitoring system for advancing keratoconus.

Cornea↗

Monitoring the thermally induced structural transitions of collagen by use of second-harmonic generation microscopy.

The thermal disruption of collagen I in rat tail tendon is investigated with second-harmonic generation (SHG) microscopy. We investigate its effects on SHG images and intensity in the temperature range 25 degrees-60 degrees C. We find that the SHG signal decreases rapidly starting at 45 degrees C. However, SHG imaging reveals that breakage of collagen fibers is not evident until 57 degrees C and worsens with increasing temperature. At 57 degrees C, structures of both molten and fibrous collagen exist, and the disruption of collagen appears to be complete at 60 degrees C. Our results suggest that, in addition to intensity measurement, SHG imaging is necessary for monitoring details of thermally induced changes in collagen structures in biomedical applications.

Animals↗

Multiphoton polarization and generalized polarization microscopy reveal oleic-acid-induced structural changes in intercellular lipid layers of the skin.

We have demonstrated that both multiphoton polarization and generalized polarization (GP) microscopy may be combined to characterize the structural changes of intercellular lipids in skin. Both polarization and GP (at 440- and 490-nm emission) images obtained by analysis of Laurdan fluorescence suggest that the treatment of oleic acid results in a skin surface with a more random packing of lipid molecules, which allows easier water penetration. Our results show that combined polarization and GP microscopy can be used to characterize the physical and chemical changes in biological structures.

Culture Techniques↗

Determination of bisphenol A in human breast milk by HPLC with column-switching and fluorescence detection.

A highly sensitive HPLC method was developed for the determination of xenoestrogenic compound, bisphenol A (BPA) in human breast milk samples. After a two-step liquid-liquid extraction, BPA was derivatized with fluorescent labeling reagent, 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl). The excess fluorescent reagent could be removed effectively using a column-switching system. The separation of DIB-BPA from endogenous materials in milk was carried out on two C(18) columns and fluorescence intensity was monitored at 475 nm with the excitation of 350 nm. A good linearity (r = 0.994) was observed of BPA in the concentration range of 0.2-5.0 ng mL(-1) in breast milk, and the detection limit was 0.11 ng mL(-1) at a signal-to-noise ratio of 3. Intra- and inter-day precision (RSD, %) were less than 8.7 and 10.4, respectively. Twenty-three breast milk samples of healthy lactating women were analyzed for the BPA concentration; the mean value was 0.61 +/- 0.20 ng mL(-1), with no correlation to the lipid content of milk samples.

Benzhydryl Compounds↗

Effects of objective numerical apertures on achievable imaging depths in multiphoton microscopy.

Multiphoton microscopy is a powerful technique for achieving three-dimensional submicron imaging in biological specimens. However, specimen optical parameters such as refractive indices and scattering coefficients can result in the loss of image resolution and decreased signal in depth. These factors are coupled to the focusing objective's numerical aperture (NA) in limiting the achievable imaging depths. In this work, we performed multiphoton imaging on aqueous fluorescent solution, human skin, and rat tail tendon to show that, under the same immersion condition, lower NA objectives can examine more deeply into biological specimens and should be used when optimal imaging depths is desired.

Animals↗

Measurement of bisphenol A levels in human blood serum and ascitic fluid by HPLC using a fluorescent labeling reagent.

A sensitive column-switching HPLC method with fluorescence detection was developed for the determination of bisphenol A (BPA) in human blood serum and ascitic fluid samples. 4-(4,5-Diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) was used as the fluorescent label, and the excess reagent was removed by a column-switching technique. Liquid-liquid extraction with chloroform was used for the pretreatment of serum and ascitic fluid samples. BPA in both the samples could be determined in the concentration range of 0.1-7.0 ppb with the detection limit of 0.04 ppb at a signal-to-noise ratio of 3. The recoveries of BPA spiked to serum and ascitic fluid were 78.6 and 77.7%, respectively. The mean concentrations of BPA (n=9) in maternal and umbilical cord blood sera obtained from healthy pregnant women were 0.46+/-0.20 and 0.62+/-0.13 ppb, respectively. BPA levels (n=21) in blood sera and ascitic fluid obtained from the patients with sterility were also determined to be 0.46+/-0.20 and 0.56+/-0.19 ppb, respectively. Relationships of BPA concentrations were observed between maternal and umbilical cord blood serum samples (r=0.626), as well as blood serum and ascitic fluid samples (r=0.785).

Ascitic Fluid↗

Simultaneous determination of arylpropionic acidic non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human plasma by HPLC with UV detection.

A simple and sensitive high-performance liquid chromatography-UV detection method was developed for the simultaneous determination of non-steroidal anti-inflammatory drugs (NSAIDs) having an arylpropionic acid moiety in pharmaceutical formulations and human plasma. Isocratic separation was employed on ODS column (250 x 4.6 mm i.d., 5 microm) at ambient temperature. The mobile phase consisted of acetonitrile, phosphate buffer (pH 3.5; 50 mM), methanol and tetrahydrofuran. The NSAIDs in the eluent were monitored under a wavelength-programme to provide their maximum absorbance. Mefenamic acid was used as an internal standard. Drugs were found to be 96.8-101.9% of their label claim in pharmaceutical formulations. One hundred microliters of human plasma samples were pretreated with a simple liquid-liquid extraction using ethyl acetate. The detection limits of compounds studied at a signal-to-noise ratio of 3 were 11.5-75 ng/ml in human plasma samples. The proposed method is simple, selective and could be applicable for routine analysis of arylpropionic acidic NSAIDs in pharmaceutical as well as in human plasma samples.

Anti-Inflammatory Agents, Non-Steroidal↗

Determination of bisphenol A in rat brain by microdialysis and column switching high-performance liquid chromatography with fluorescence detection.

A sensitive column switching HPLC-fluorescence detection for determination of bisphenol A (BPA) in rat brain by coupling with microdialysis was developed. A microdialysis probe was inserted into the hypothalamus of rat brain and an artificial cerebrospinal fluid was used for perfusion. BPA in brain dialysate was subjected to a fluorescent derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl), and the excess reagent was removed by a column-switching technique. Separation was carried out on two ODS semimicro-columns with the mobile phase of acetonitrile-H(2)O-methanol-tetrahydrofuran (55:10:35:2.5, v/v) and acetonitrile-0.1 M acetate buffer (pH 3.0)-methanol (35:10:55, v/v) at a flow rate of 0.10 and 0.15 mL/min for a precolumn and a separation column, respectively. Fluorescence intensity was monitored at 475 nm with excitation of 350 nm. BPA could be sensitively detected at 0.3 ppb in 60 micro L brain microdialysate at a signal-to-noise ratio of 3. By the proposed method, concentrations of BPA in rat brain and plasma were monitored for 8 h after single i.v. or oral administration. It is proved that BPA is capable of penetrating the blood-brain barrier. The ratio of the area under the concentration-time curve of BPA in rat brain to that in blood was estimated to be about 3.0-3.8%.

Animals↗

Spherical aberration correction in multiphoton fluorescence imaging using objective correction collar.

Multiphoton microscopy has evolved into a powerful bioimaging tool in three dimensions. However, the ability to image biological specimens in-depth can be hindered by sample spherical aberration and scattering. These two phenomena can result in the degradation of image resolution and the loss of detected multiphoton signal. In this work, we use the correction collar (for cover glass thickness) associated with a water immersion objective in an attempt to improve multiphoton imaging. In the two samples we examined (human skin and rat tail tendon), we found that while the improvement in image resolution was not visible qualitatively, the measured axial fluorescence or second harmonic generation signal profiles indicate that the use of the correction collar can help to improve the detected multiphoton signals. The maximum increases are 36% and 57% for the skin (sulforhodamine B fluorescence) and tendon (second harmonic generation) specimens, respectively. Our result shows that for in-depth multiphoton imaging, the correction collar may be used to correct for spherical aberration. However, each tissue type needs to be examined to determine the optimal correction collar setting to be used.

Animals↗

Prediction of heat-induced collagen shrinkage by use of second harmonic generation microscopy.

Collagen shrinkage associated with denaturation from thermal treatment has a number of important clinical applications. However, individualized treatment is hindered by the lack of reliable noninvasive methods to monitor the process of collagen denaturation. We investigate the serial changes of collagen denaturation from thermal treatment of rat tail tendons at 58 degrees C by use of second harmonic generation (SHG) microscopy. We find that rat tail tendon shrinks progressively from 0 to 9 min of thermal treatment, and remains unchanged in length upon further thermal treatment. The SHG intensity also decreases from 0 to 9 min of thermal treatment and becomes barely detectable from further thermal treatment. Collagen shrinkage and the SHG intensity are well correlated in a linear model. In addition, SHG imaging reveals a tiger-tail-like pattern of collagen denaturation. The bands of denatured collagen progressively widen from increased thermal treatment and completely replace the adjacent bands of normal collagen after 9 min of thermal treatment. Our results show that collagen denaturation in rat tail tendon from thermal treatment is inhomogeneous, and that SHG intensity can be used to predict the degree of thermally induced collagen shrinkage. With additional development, this approach has the potential to be used in biomedical applications.

Animals↗