On-chip microdialysis system with flow-through sensing components.

Microdialysis probes have been used for diabetes treatment as continuous monitoring system coupled to a glucose sensor. An on-chip microdialysis system with in-line sensing electrodes is demonstrated. As a first step towards greater biosensor integration with this miniaturized microdialysis system, a stacked system with in-line sensing electrodes was developed. Impedance electrodes sputtered within the microchannels were used to determine fluid electrical resistance from a dialyzed phosphate buffered saline (PBS) solution, which characterizes solution conductivity as a function of PBS concentration. The permeability of the membrane to the salt ions was obtained as 0.246+/-0.028 microm/s (15 nm pores). Subsequently, experiments measuring PBS dialysis in the time-domain at 64.4% recovery were conducted. The PBS concentration of the reservoir was changed in both a step response and sinusoidally with an 800 s period. The subsequently measured impedance indicates that the system is able to continuously track concentration changes in the reservoir with a 210 s system response delay. Most of this delay is due to the dead volume within the tubing between the syringe pumps and the microsystem. In addition, the predicted response was modeled using linear systems theory and matches the experimental measurements (r=0.98). This system is expected to have the proper sensitivity to track physiologically relevant concentration changes of biomolecules such as glucose (which has a physiological maximum change rate of approximately 4 mg/dl min with a periodicity of 1h or greater) with minimal lag time and amplitude reduction.

Electrochemistry↗

Components of an integrated microfluidic device for continuous glucose monitoring with responsive insulin delivery.

Miniaturized medical diagnostic and treatment devices are currently being developed. Microneedles and miniaturized microdialysis systems are particularly well suited to impact diabetes treatment for continuous glucose monitoring and feedback-controlled insulin delivery. Microneedles are an attractive advanced drug delivery system used to mechanically penetrate the skin and inject insulin intradermally where it is rapidly absorbed by the capillary bed into the bloodstream. The real advantage of microneedle-enhanced drug delivery lies in the fact that drug is actively injected into a patient so the dosage may be varied with time to allow complex drug delivery profiles. The delivery is independent of the drug composition and merely relies on the subsequent drug absorption into the bloodstream. A miniaturized microdialysis probe for continuous glucose sensing has also been designed. Microdialysis is based upon controlling the mass transfer rate of glucose diffusing across a semipermeable membrane into a dialysis fluid while excluding larger molecules such as proteins. Polymer microdialysis membranes are integrated with microfluidic systems. Because of the high surface area to fluid volume ratio of miniaturized fluid channels, faster recovery of glucose to increase glucose sensing frequency is expected. This work highlights recent advances made in the design and fabrication of microneedles to make them more biocompatible and more fracture resistant in order to effectively enter the biomedical market. In addition, the design of a miniaturized microdialysis system for increased glucose sampling frequency is presented. The sensing and infusion technologies may be combined into a miniaturized "artificial pancreas" for minimally invasive feedback-controlled insulin delivery.

Blood Glucose↗