PubMed Health⌕ Search

Biomedical subjects

Yi-ning Wang

Publications and source records attributed to Yi-ning Wang.

10 recordsLinked to original sources

[Comparison of coronary artery bypass graft imaging between 64-slice and 16-slice spiral CT].

OBJECTIVE: To compare the coronary artery bypass graft (CABG) imaging between 16-slice spiral CT and 64-slice spiral CT. METHODS: Totally 27 patients with CABG received multi-slice spiral CT imaging and the results were retrospectively analyzed. Among them, 8 patients received 16-slice spiral CT scanning, 19 patients received 64-slice spiral CT scanning. RESULTS: The evaluability rates of 64-slice spiral CT in evaluating the proximal anastomosis, bypass graft, distal anastomosis, and distal blood vessel were 100%, 100%, 90.2%, and 93.9%, respectively, while those of 16-slice spiral CT were 92.3%, 95.2%, 90.0%, and 90.0%, respectively. The patency rates of the above four aspects of 64-slice spiral CT were 66.7%, 70.0%, 71.7%, and 70.0%, respectively, while those of 16-slice spiral CT were 83.3%, 85.0%, 83.3%, and 88.9% . CONCLUSIONS: 64-slice spiral CT is superior to 16-slice spiral CT in CABG imaging. It can be used as a non-invasive tool for the post-operative follow-up of CABG.

Aged↗

[Comparison of coronary angiography between 64-slice and 16-slice spiral CT].

OBJECTIVE: To compare the image quality and visibility of arteries of 64-slice spiral coronary CT angiography (CTA) with those of 16-slice spiral coronary CTA, and to evaluate the diagnostic accuracy of 64-slice spiral CT for the assessment of coronary artery stenosis. METHODS: Totally 100 patients (Group A) with suspected coronary artery diseases (CAD) were examined by 64-slice spiral CT, 48 of whom also underwent conventional coronary angiography (CAG). Another 100 patients (Group B) with suspected CAD were studied by 16-slice spiral CT. Patients with a heart rate above 70 bpm received oral beta-blockers before the scan. Data were retrospectively analyzed and reviewed by two observers. Image quality was assessed by using a 3-point grading scale from excellent (1) to non-assessable (3) and the rate of displayed coronary branches was calculated. The left main artery (LM), left anterior descending artery (LAD), circumflex artery (CX), and right coronary artery (RCA) were screened for the presence of over 50% stenosis. RESULTS: The mean heart rates of two groups showed no significant difference [(61 +/- 8) bpm vs. (61 +/- 7) bpm, P > 0.05]. The mean scan time of Group A was significantly shorter than that of Group B [(11.9 +/- 0.9) s vs. (22.2 +/- 1.1) s, P < 0.01]. In the evaluation of image quality, better results were obtained in Group A than in Group B (1.20 +/- 0.47 vs. 1.37 +/- 0. 63, P < 0.05). The visibility of proximal arteries was similar between two groups, while the visibility of some distal arteries and small branches was found higher in Group A than in Group B (LAD distal 92% vs. 48%, CX distal 98% vs. 89%, the first obtuse marginal (OMI) 93% vs. 84%, cone branch (CB) 86% vs. 71%, P < 0.05). Compared with CAG, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 64-slice spiral coronary CTA to identify over 50% stenosis were 94.9% (56/59), 93.2% (124/133), 86.2% (56/65), and 97.6% (124/127), respectively. CONCLUSIONS: With higher temporal and spatial resolution, 64-slice spiral CT provides improved image quality and visibility of small branches as compared with 16-slice spiral CT. 64-slice spiral coronary CTA allows reliable non-invasive diagnosis of obvious coronary artery stenosis.

Aged↗

[Assessment of coronary stent lumen visibility and patency by 64-slice spiral CT angiography].

OBJECTIVE: To evaluate the clinical value of assessment of coronary stent patency by 64-slice spiral CT coronary angiography. METHODS: Totally 29 patients (59 stents) were investigated using a retrospective ECG-gated enhanced scan by 64-slice spiral CT at a mean interval of (28.4 +/- 21.2) months after coronary stent implantation. Axial multi-planar reconstruction (MPR) of the stents and curved-planar reconstruction (CPR) through the stents were evaluated for image quality on a 5-point scale (1 = excellent, 5 = uninterpretable) and lumen diameter. Stent lumen diameter was compared with the vessel diameter proximal of the stents to assess the in-stent lumen visibility. Conventional coronary angiography was performed in 5 patients, and 9 stents were evaluated. RESULTS: The image quality was good to excellent on average (scores: 1.94 +/- 0.84), depending on heart rate, breath movement, and stent location. Stent lumen was visible, on average a percentage off (76.1 +/- 11.1)% of the lumen diameter. All the 9 stents were correctly detected as being patent, which was confirmed by conventional coronary angiography. CONCLUSION: 64-slice spiral CT is a useful tool to assess the coronary stent patency.

Adult↗

[Assessment of global left ventricular function with multi-slice spiral computed tomography].

OBJECTIVE: To investigate the value of multi-slice spiral computed tomography (MSCT) in the determination of global left ventricular function. METHODS: Twenty-nine patients with confirmed or suspected coronary heart diseases were imaged with a contrast-enhanced retrospective electrocardiogram (ECG) -gated technique on a 64-slice spiral CT scanner. The data sets were reconstructed at both end-diastolic and end-systolic phases in order to measure left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), left ventricular stroke volume (LVSV), and left ventricular ejection fraction (LVEF). The results were compared with corresponding values obtained from conventional left ventriculography (LVG). RESULTS: LVEDV, LVESV, LVSV, and LVEF obtained with 64-slice spiral CT were significantly correlated with the LVG data (r = 0. 887-0.956, P < 0.001). According to the Bland-Altman approach, the mean differences for LVEDV, LVESV, LVSV, and LVEF were -2.3 ml, 4.1 ml, -6.4 ml, and - 3.5%, respectively. The limits of agreement for LVEDV, LVESV, LVSV, and LVEF were -27.2-22.4 ml, -10.2-18.4 ml, -26.4-13.6 ml, and -9.8%-3.0%, respectively. CONCLUSION: MSCT has clinically acceptable agreement with LVG for the quantification of global left ventricular function.

Adult↗

[An experimental study on alveolar ridge preservation prior to dental implant placement].

OBJECTIVE: To evaluate the combination of surgical grade calcium sulfate hemihydrate (SGCS) and platelet-rich plasma (PRP) for alveolar ridge preservation prior to implant placement. METHODS: Changes of bone quantity and quality in extraction sites following the SGCS/PRP and SGCS implantations were investigated by spiral computer tomography scan, bone scintigraphy, radiographic, histological and histomorphometric examinations. RESULTS: The placement of SGCS/PRP reduced the resorption of the alveolar ridge. It also promoted bone metabolism and bone-to-implant contact. The addition of PRP to SGCS achieved the enhancement of the bone metabolism only at the early healing phase. CONCLUSIONS: In this animal experiment, SGCS/PRP may be used as fresh extraction sockets graft for alveolar ridge preservation prior to implant placement.

Alveolar Bone Loss↗

[Microtensile bond strength and morphological evaluations of total-etch and self-etch adhesives to caries-affected dentin].

OBJECTIVE: To evaluate the microtensile bond strength and bond interface of total-etch or self-etch adhesives to normal dentin and caries-affected dentin. METHODS: A total of 20 molars with occlusal caries lesion were used. The caries-affected dentin was obtained by removing the caries-infected dentin under the guidance of the caries detector. Beyond the level of caries-affected dentin all the enamel and partial dentin were removed. The adhesive systems, two total-etch adhesives (All-Bond 2, Prime&Bond NT) and two self-etch adhesives (Clearfil SE Bond, Xeno III) were applied respectively under the instructions of manufacturers. A block of composite resin was build up superficially. All the teeth were sectioned to obtain bar-shaped specimens with bonded surface area about 0.9 mm x 0.9 mm. The specimens were divided into normal dentin group and caries-affected dentin group via stereomicroscope. The bond strength was tested in a microtensile tester with a crosshead speed of 1 mm/min. The mean values of bond strength were compared using two-way ANOVA. The bonding interface between the dentin and adhesives was qualitatively evaluated under the observation of scanning electron microscope (SEM). RESULTS: Two-way ANOVA revealed a significant influence of both the type of dentin and the adhesive systems tested on microtensile bond strength values. All the adhesives attained higher strength in normal dentin. In normal dentin, there was no significant difference between total-etch and self-etch adhesives. In caries-affected dentin, bond strength of Xeno III was significantly lower than the others. For SEM, the hybrid layer in caries-affected dentin was thicker but more porous than that in normal dentin. Compared with normal dentin, there was fewer resin tag exhibited in caries-affected dentin and no lateral branches were observed. CONCLUSIONS: The total-etch adhesive had higher bond strength than self-etch adhesive systems in caries-affected dentin.

Acid Etching, Dental↗

[Effect of three backgrounds on the final color of Solidex with six different thickness].

OBJECTIVE: To analyze the final color of Solidex in six thickness interacting with three different backgrounds. METHODS: Five specimens of Solidex in each shade A1, A3, and C2 were fabricated at thickness of 1.0, 1.2, 1.4, 1.6, 1.8, and 2.0 mm. The CIE L(*)a(*)b(*) values of specimens were measured using a colorimeter (ShadeEye NCC) to determine the colorimetric difference, when the specimens overlaid on different backgrounds. RESULTS: When the thickness was more than 1.8 mm, the color difference (DeltaE(*)ab < 1) was not perceived by human observers. When the thickness was 1.4 mm or less than 1.4 mm, the color difference (DeltaE(*)ab > 2.72) was considered clinically unacceptable between alloy background and two types of composite resin background. CONCLUSIONS: Alloy background had more evident influence on the final color of Solidex than composite resin background. When making metal-free crown restoration using Solidex, it was advisable to make the composite resin more than 1.8 mm thick.

Chromium Alloys↗

[A preliminary study on the color effect of IPS Empress all-ceramic veneers].

OBJECTIVE: To evaluate the opaquing capacity, color compatibility and stability of IPS Empress all-ceramic veneers. METHODS: A total of 86 IPS Empress all-ceramic veneers were made for 18 patients. The patients were divided into three groups: Group A was tetracycline teeth, 64 veneers for 5 patients; Group B was non-tetracycline teeth, 22 veneers for 13 patients; Group C was 22 natural vital teeth with normal color as control group. Before and after veneers were inserted, ShadeEye NCC was employed to obtain L * a * b * values of each tooth. The values of cemented veneers used as the baseline, the L * a * b * values of each veneer were measured half a year, 1 year, and 2 years after restoration respectively. All L * a * b * values at different evaluation times were analyzed by SPSS 10.0. RESULTS: Before and after veneers were restored, the L * a * b * values of both Group A and Group B were significantly different, the color difference being 5.01 and 4.15 respectively. The color difference between Group A and selected shade guides was 2.45. Compared with the baseline value, the L * value of Group A significantly decreased 2 years after restoration, but the DeltaE of different evaluation times was not significantly different. The color difference between Group B and Group C was 0.22 and there was no significant color difference after restoration. CONCLUSIONS: IPS Empress all-ceramic veneers have excellent opaquing capacity, color compatibility and stability to non-tetracycline teeth. To tetracycline teeth IPS Empress all-ceramic veneers have a certain opaquing capacity, but they cannot completely match with shade guides; the L * value is significantly different after restoration and further studies are needed to evaluate its color effect.

Adolescent↗

[Adhesion of oral microorganisms on dental porcelain polished and glazed].

OBJECTIVE: This study compared the roughness of porcelain polished or glazed surfaces and the adhesion of oral streptococcus mutans to them in vitro. METHODS: 30 porcelain samples were made. Porcelain samples in group A were polished with diamond paste. Porcelain samples were glazed in group B and were polished with Al2O3 (240#) bur in group C. Their roughness values were measured by profilometer. Standardized cell suspensions were incubated with test samples for one hour at 37 degrees C, then retained cells were counted by image analysis (percentage area of a microscopic field covered by cells). RESULTS: Roughness values of group A, B, C were respectively (0.1987 +/- 0.057) microm, (0.1990 +/- 0.091) microm, (0.4260 +/- 0.174) microm. There was no significantly difference between group A and group B. The roughness samples in group C were significantly rougher than that in the other groups. The amount of retained cells in group A, group B, group C was respectively (15.92 +/- 4.37)%, (16.39 +/- 6.31)% and (41.48 +/- 12.1)%. There was no significant difference between the cell adhesion on porcelain surface glazed and polished, but more bacteria adhered on the porcelain surface in group C. CONCLUSIONS: Porcelain surface polished treatment was clinically acceptable compared with its glazed. They all exhibited the least amount of bacteria adhesion. The more porcelain surface was rough, the more bacteria adhered on it.

Bacterial Adhesion↗

[Cell behavior of periodontal ligament cells cultured on commercially pure titanium].

OBJECTIVE: To study the cell behavior of periodontal ligament cells (PDLCs) cultured on commercially pure titanium (cpTi) by cell morphology, cell counting and osteoclin (OC) immunofluorescent staining. METHODS: 1 x 10(5)/ml PDLCs in 2 ml culture medium were seeded on cpTi discs fixed in 24-well culture plates. Morphological study of cell attachment was observed by scanning electron microscope (SEM) and fluorescence microscopy. Cell adhesion was analyzed by MTT at 0.5, 1, 2, 4 hours respectively. OC was directly observed by immunofluorescent staining. RESULTS: PDLCs could attach and spread on cpTi discs. SEM showed that PDLCs had pseudopod-like protuberance. PDLCs showed different attaching phase and reached saturation in cell number at the early stage. The cells and ECM could express OC 7 days later. CONCLUSION: PDLCs show a regular, dynamic pattern in early stage and they can keep proliferating and differentiating on CpTi in vitro. It was indicated that the biological function of PDLCs around dental implant should be reconsidered.

Cells, Cultured↗