PubMed Health⌕ Search

Biomedical subjects

Yian Jin

Publications and source records attributed to Yian Jin.

4 recordsLinked to original sources

Analysis of intraocular lens power calculation for eyes with previous myopic LASIK.

PURPOSE: To evaluate the effectiveness of a manual keratometry (K) adjusted value for intraocular lens (IOL) power calculation in patients who underwent cataract surgery following previous myopic LASIK. METHODS: Sixteen eyes of 14 consecutive patients who underwent cataract surgery after previous LASIK were evaluated retrospectively. All IOL powers were calculated using an adjusted K value (K minus 1.0 diopter [D]) with the Binkhorst II formula aiming for -0.75 to -1.00 D final refraction. Additionally, the IOL power for each eye was retrospectively calculated using K, refractive-derived K, and adjusted K with the Binkhorst II, Holladay I, and SRK/T formulas. The final refraction was used as a criterion of accuracy of each approach. RESULTS: Uncorrected visual acuity > or = 20/40 was achieved in 14 (87.5%) of 16 eyes. The mean postoperative spherical equivalent refraction was -0.41 +/- 0.57 D (range: +0.50 to -2.00 D). Twelve (75%) of 16 eyes were within +/- 0.50 D of emmetropia and 15 (94%) of 16 eyes were within +/- 1.00 D. No eye was > +1.00 D. CONCLUSIONS: Using an adjusted K with the Binkhorst II formula, aiming for -0.75 to -1.00 D, and with the Holladay I formula, aiming for -0.50 to -1.00 D, measuring K with a regular manual keratometer permits determination of an IOL power after myopic LASIK without the need of preoperative LASIK refractive data.

Adult↗

Cohort study of 27 cases of endophthalmitis at a single institution.

PURPOSE: To identify potential risk factors associated with post-cataract surgery bacterial endophthalmitis. SETTING: The John A. Moran Eye Center, Salt Lake City, Utah, USA. METHODS: This retrospective cohort study consisted of patients who had surgery for cataract(s) at this eye hospital. A 10% sampling of all patients operated on for cataract surgery from January 1, 1996, to December 31, 2002, were compared with all cases of postcataract surgery bacterial endophthalmitis during this same time period at this institution. The main outcome measure(s) included surgical complication, first postoperative day wound leak, incision placement and location, intraocular lens material, whether a suture was placed, antibiotic used, collagen shield use, and whether the eye was patched. RESULTS: A total of 1525 patients were in the control cohort, and there were 27 cases of endophthalmitis. In a multivariate regression analysis, the factors found to be statistically associated with endophthalmitis were (1) wound leak on the first postoperative day (odds ratio [OR] 44 +/- 42; confidence interval [CI] 6.85 to 287; P<.001); (2) capsular or zonular surgical complication (OR 17.2 +/- 14.2; CI 3.44 to 86.4; P=.001); (3) topical antibiotic started the day after surgery rather than the day of surgery (OR 13.7 +/- 12.9; CI 2.17 to 90.9; P=.005); (4) use of ciprofloxacin rather than ofloxacin topically after surgery (OR 5.3 +/- 3.6; CI 1.41 to 20.0; P=.014); (5) not patching after surgery (OR 7.1 +/- 5.6; CI 1.47 to 36.4; P=.015); and (6) not placing a collagen shield soaked in antibiotic (OR 2.7 +/- 1.3; CI 1.06 to 7.14 P=.037). CONCLUSION: In sutureless cataract surgery, surgical complications and wound leak on the first postoperative day were most strongly associated with endophthalmitis.

Aged↗

Legacy AdvanTec and Sovereign WhiteStar: a wound temperature study.

PURPOSE: To assess the wound temperature of the Sovereign WhiteStar (S-WS) (AMO) and Legacy AdvanTec (L-ADV) (Alcon) phacoemulsification systems. SETTING: John A. Moran Eye Center, Health Sciences Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Phacoemulsification using 20-gauge, 30-degree straight tips with the L-ADV and S-WS systems was performed in fresh cadaver eyes. The power was set at 50%, and aspiration was 12 mL/min; the L-ADV was run at 15 pulses per second (pps) and the S-WS at WS CF (6 milliseconds on, 12 milliseconds off). Temperature was measured at 5-second intervals for 60 seconds using a microthermistor placed in the wound. The phaco tip was angled 30 degrees to increase wound-tissue contact. At 10 seconds, the flow was clamped to simulate occlusion. Five runs, sleeved and unsleeved, were averaged for the phaco tip. RESULTS: The mean temperature was significantly higher with L-ADV than with S-WS (from 10 seconds on in the sleeved condition and from 5 seconds on in the unsleeved condition after the aspiration line was clamped). In 2 of 5 sleeved runs and 4 of 5 unsleeved runs, the L-ADV handpiece decreased power as the temperature increased. One run with the L-ADV with sleeve showed signs of wound burn. There were no signs of wound burn with the S-WS. The highest temperature recorded was 57.5 degrees C with the L-ADV and 38.6 degrees C with the S-WS. Power tests showed L-ADV protected the stroke length and S-WS had constant power except in air where it increased power. CONCLUSIONS: There was less increase in wound temperature over time with the S-WS than with the L-ADV system in sleeved and unsleeved simulated surgery in human eye-bank eyes. Because the ultrasound handpieces respond differently under different load scenarios, meaningful comparisons of pulsing features are difficult to create.

Anterior Eye Segment↗

Interface fluid after laser in situ keratomileusis.

PURPOSE: To describe a case of interface fluid after laser in situ keratomileusis (LASIK) and review the literature on this rare complication after LASIK. METHODS: We present a case report and literature review. Articles for this review were chosen from electronic database and manual literature searches. MEDLINE searches were made from 1990 to April 2002, using the key words "interface fluid" and "LASIK." RESULTS: A 40-year-old man had uneventful LASIK for residual refractive error from previous penetrating keratoplasty in his right eye. Diffuse lamellar keratitis began 1 day postoperatively. Topical corticosteroids were administered. Six weeks after LASIK, a layer of interface fluid developed. Intraocular pressure was 9 mmHg when measured centrally by Goldmann applanation tonometry and 30 mmHg by Tono-pen tonometry. The interface fluid resolved with antiglaucoma agents and corticosteroids combined with cyclosporine. CONCLUSIONS: This case, along with other reported cases, demonstrate the clinical features of interface fluid after LASIK.

Adult↗