PubMed Health⌕ Search

Biomedical subjects

Yimo Zhang

Publications and source records attributed to Yimo Zhang.

5 recordsLinked to original sources

Distributed measurement of birefringence dispersion in polarization-maintaining fibers.

A new method to measure the birefringence dispersion in high-birefringence polarization-maintaining fibers is presented using white-light interferometry. By analyzing broadening of low-coherence interferograms obtained in a scanning Michelson interferometer, the birefringence dispersion and its variation along different fiber sections are acquired with high sensitivity and accuracy. Birefringence dispersions of two PANDA fibers at their operation wavelength are measured to be 0.011 ps/(km nm) and 0.018 ps/(km nm), respectively. Distributed measurement capability of the method is also verified experimentally.

Journal Article↗

Development of a parallel demodulation system used for extrinsic Fabry-Perot interferometer and fiber Bragg grating sensors.

A parallel demodulation system for extrinsic Fabry-Perot interferometer (EFPI) and fiber Bragg grating (FBG) sensors is presented, which is based on a Michelson interferometer and combines the methods of low-coherence interference and a Fourier-transform spectrum. The parallel demodulation theory is modeled with Fourier-transform spectrum technology, and a signal separation method with an EFPI and FBG is proposed. The design of an optical path difference scanning and sampling method without a reference light is described. Experiments show that the parallel demodulation system has good spectrum demodulation and low-coherence interference demodulation performance. It can realize simultaneous strain and temperature measurements while keeping the whole system configuration less complex.

Journal Article↗

Parallel demodulation system and signal-processing method for extrinsic Fabry-Perot interferometer and fiber Bragg grating sensors.

A parallel demodulation system for extrinsic Fabry-Perot interferometer (EFPI) and fiber Bragg grating (FBG) sensors is presented that is based on a Michelson interferometer and combines the methods of low-coherence interference and Fourier transform spectrum. Signals from EFPI and FBG sensors are obtained simultaneously by scanning one arm of a Michelson interferometer, and an algorithm model is established to process the signals and retrieve both the wavelength of the FBG and the cavity length of the EFPI at the same time, which are then used to determine the strain and temperature.

Journal Article↗

Fourier algorithm method for reconstruction of large-aperture digital holograms based on phase compensation.

To simplify the reconstruction calculation of a large-aperture digital hologram we propose a novel Fourier-transformation reconstruction algorithm. When the reconstructed wave is the same as or similar to the reference wave, the higher-order phase term of reconstruction can be compensated for. For example, the variation between the higher-order phase term and the aperture angle with a different field of view in in-line phase-shifting digital holography is analyzed.

Journal Article↗

Comparison of analog and digital Fourier transforms in medical image analysis.

The effectiveness and limitations of medical image processing using analog and digital methods are studied. Several types of errors introduced during the image processing are analyzed. For the analog optical Fourier transform, errors are introduced by the vignetting effect and lens aberration. For the digital Fourier transform, errors are introduced by the aliasing effect and the band limit. To compare the results obtained by the two techniques, a set of x-ray images was processed both optically and digitally. The former was achieved by an optical system containing a large Fourier telephoto lens and the latter by a personal computer using a Fourier transform algorithm. The veracity of both the optical and digital Fourier spectra is analyzed. Our results indicate that the optical method has high speed due to parallel processing. High veracity can be achieved in high frequency regions by using an optimal optical system. In comparison, the digital method has the advantages of high processing precision and programmability, but has low processing speed. The comparison of the two different techniques presented in this article can provide a basis for selection of the processing method in different clinical settings. Even with today's fast computers, the optical method is still suitable for many clinical applications. The best choice lies in an analog-digital combination.

Algorithms↗