Temporal and spectral cues in Mandarin tone recognition.

This study evaluates the relative contributions of envelope and fine structure cues in both temporal and spectral domains to Mandarin tone recognition in quiet and in noise. Four sets of stimuli were created. Noise-excited vocoder speech was used to evaluate the temporal envelope. Frequency modulation was then added to evaluate the temporal fine structure. Whispered speech was used to evaluate the spectral envelope. Finally, equal-amplitude harmonics were used to evaluate the spectral fine structure. Results showed that normal-hearing listeners achieved nearly perfect tone recognition with either spectral or temporal fine structure in quiet, but only 70%-80% correct with the envelope cues. With the temporal envelope, 32 spectral bands were needed to achieve performance similar to that obtained with the original stimuli, but only four bands were necessary with the additional temporal fine structure. Envelope cues were more susceptible to noise than fine structure cues, with the envelope cues producing significantly lower performance in noise. These findings suggest that tonal pattern recognition is a robust process that can make use of both spectral and temporal cues. Unlike speech recognition, the fine structure is more important than the envelope for tone recognition in both temporal and spectral domains, particularly in noise.

Acoustic Stimulation↗

Speech recognition with amplitude and frequency modulations.

Amplitude modulation (AM) and frequency modulation (FM) are commonly used in communication, but their relative contributions to speech recognition have not been fully explored. To bridge this gap, we derived slowly varying AM and FM from speech sounds and conducted listening tests using stimuli with different modulations in normal-hearing and cochlear-implant subjects. We found that although AM from a limited number of spectral bands may be sufficient for speech recognition in quiet, FM significantly enhances speech recognition in noise, as well as speaker and tone recognition. Additional speech reception threshold measures revealed that FM is particularly critical for speech recognition with a competing voice and is independent of spectral resolution and similarity. These results suggest that AM and FM provide independent yet complementary contributions to support robust speech recognition under realistic listening situations. Encoding FM may improve auditory scene analysis, cochlear-implant, and audiocoding performance.

Cochlear Implants↗

Speech and melody recognition in binaurally combined acoustic and electric hearing.

Speech recognition in noise and music perception is especially challenging for current cochlear implant users. The present study utilizes the residual acoustic hearing in the nonimplanted ear in five cochlear implant users to elucidate the role of temporal fine structure at low frequencies in auditory perception and to test the hypothesis that combined acoustic and electric hearing produces better performance than either mode alone. The first experiment measured speech recognition in the presence of competing noise. It was found that, although the residual low-frequency (<1000 Hz) acoustic hearing produced essentially no recognition for speech recognition in noise, it significantly enhanced performance when combined with the electric hearing. The second experiment measured melody recognition in the same group of subjects and found that, contrary to the speech recognition result, the low-frequency acoustic hearing produced significantly better performance than the electric hearing. It is hypothesized that listeners with combined acoustic and electric hearing might use the correlation between the salient pitch in low-frequency acoustic hearing and the weak pitch in the envelope to enhance segregation between signal and noise. The present study suggests the importance and urgency of accurately encoding the fine-structure cue in cochlear implants.

Acoustic Stimulation↗

Perceptual consequences of disrupted auditory nerve activity.

Perceptual consequences of disrupted auditory nerve activity were systematically studied in 21 subjects who had been clinically diagnosed with auditory neuropathy (AN), a recently defined disorder characterized by normal outer hair cell function but disrupted auditory nerve function. Neurological and electrophysical evidence suggests that disrupted auditory nerve activity is due to desynchronized or reduced neural activity or both. Psychophysical measures showed that the disrupted neural activity has minimal effects on intensity-related perception, such as loudness discrimination, pitch discrimination at high frequencies, and sound localization using interaural level differences. In contrast, the disrupted neural activity significantly impairs timing related perception, such as pitch discrimination at low frequencies, temporal integration, gap detection, temporal modulation detection, backward and forward masking, signal detection in noise, binaural beats, and sound localization using interaural time differences. These perceptual consequences are the opposite of what is typically observed in cochlear-impaired subjects who have impaired intensity perception but relatively normal temporal processing after taking their impaired intensity perception into account. These differences in perceptual consequences between auditory neuropathy and cochlear damage suggest the use of different neural codes in auditory perception: a suboptimal spike count code for intensity processing, a synchronized spike code for temporal processing, and a duplex code for frequency processing. We also proposed two underlying physiological models based on desynchronized and reduced discharge in the auditory nerve to successfully account for the observed neurological and behavioral data. These methods and measures cannot differentiate between these two AN models, but future studies using electric stimulation of the auditory nerve via a cochlear implant might. These results not only show the unique contribution of neural synchrony to sensory perception but also provide guidance for translational research in terms of better diagnosis and management of human communication disorders.

Acoustic Stimulation↗

Auditory temporal processes in normal-hearing individuals and in patients with auditory neuropathy.

OBJECTIVE: To study objectively auditory temporal processing in a group of normal hearing subjects and in a group of hearing-impaired individuals with auditory neuropathy (AN) using electrophysiological and psychoacoustic methods. METHODS: Scalp recorded evoked potentials were measured to brief silent intervals (gaps) varying between 2 and 50ms embedded in continuous noise. Latencies and amplitudes of N100 and P200 were measured and analyzed in two conditions: (1) active, when using a button in response to gaps; (2) passive, listening, but not responding. RESULTS: In normal subjects evoked potentials (N100/P200 components) were recorded in response to gaps as short as 5ms in both active and passive conditions. Gap evoked potentials in AN subjects appeared only with prolonged gap durations (10-50ms). There was a close association between gap detection thresholds measured psychoacoustically and electrophysiologically in both normals and in AN subjects. CONCLUSIONS: Auditory cortical potentials can provide objective measures of auditory temporal processes. SIGNIFICANCE: The combination of electrophysiological and psychoacoustic methods converged to provide useful objective measures for studying auditory cortical temporal processing in normals and hearing-impaired individuals. The procedure used may also provide objective measures of temporal processing for evaluating special populations such as children who may not be able to provide subjective responses.

Acoustic Stimulation↗

A dominantly inherited progressive deafness affecting distal auditory nerve and hair cells.

We have studied 72 members belonging to a large kindred with a hearing disorder inherited in an autosomal dominant pattern. We used audiological, physiological, and psychoacoustic measures to characterize the hearing disorders. The initial phenotypic features of the hearing loss are of an auditory neuropathy (AN) with abnormal auditory nerve and brainstem responses (ABRs) and normal outer hair cell functions [otoacoustic emissions (OAEs) and cochlear microphonics (CMs)]. Psychoacoustic studies revealed profound abnormalities of auditory temporal processes (gap detection, amplitude modulation detection, speech discrimination) and frequency processes (difference limens) beyond that seen in hearing impairment accompanying cochlear sensory disorders. The hearing loss progresses over 10-20 years to also involve outer hair cells, producing a profound sensorineural hearing loss with absent ABRs and OAEs. Affected family members do not have evidence of other cranial or peripheral neuropathies. There was a marked improvement of auditory functions in three affected family members studied after cochlear implantation with return of electrically evoked auditory brainstem responses (EABRs), auditory temporal processes, and speech recognition. These findings are compatible with a distal auditory nerve disorder affecting one or all of the components in the auditory periphery including terminal auditory nerve dendrites, inner hair cells, and the synapses between inner hair cells and auditory nerve. There is relative sparing of auditory ganglion cells and their axons.

Acoustic Impedance Tests↗

Music perception with temporal cues in acoustic and electric hearing.

OBJECTIVE: The first specific aim of the present study is to compare the ability of normal-hearing and cochlear implant listeners to use temporal cues in three music perception tasks: tempo discrimination, rhythmic pattern identification, and melody identification. The second aim is to identify the relative contribution of temporal and spectral cues to melody recognition in acoustic and electric hearing. DESIGN: Both normal-hearing and cochlear implant listeners participated in the experiments. Tempo discrimination was measured in a two-interval forced-choice procedure in which subjects were asked to choose the faster tempo at four standard tempo conditions (60, 80, 100, and 120 beats per minute). For rhythmic pattern identification, seven different rhythmic patterns were created and subjects were asked to read and choose the musical notation displayed on the screen that corresponded to the rhythmic pattern presented. Melody identification was evaluated with two sets of 12 familiar melodies. One set contained both rhythm and melody information (rhythm condition), whereas the other set contained only melody information (no-rhythm condition). Melody stimuli were also processed to extract the slowly varying temporal envelope from 1, 2, 4, 8, 16, 32, and 64 frequency bands, to create cochlear implant simulations. Subjects listened to a melody and had to respond by choosing one of the 12 names corresponding to the melodies displayed on a computer screen. RESULTS: In tempo discrimination, the cochlear implant listeners performed similarly to the normal-hearing listeners with rate discrimination difference limens obtained at 4-6 beats per minute. In rhythmic pattern identification, the cochlear implant listeners performed 5-25 percentage points poorer than the normal-hearing listeners. The normal-hearing listeners achieved perfect scores in melody identification with and without the rhythmic cues. However, the cochlear implant listeners performed significantly poorer than the normal-hearing listeners in both rhythm and no-rhythm conditions. The simulation results from normal-hearing listeners showed a relatively high level of performance for all numbers of frequency bands in the rhythm condition but required as many as 32 bands in the no-rhythm condition. CONCLUSIONS: Cochlear-implant listeners performed normally in tempo discrimination, but significantly poorer than normal-hearing listeners in rhythmic pattern identification and melody recognition. While both temporal (rhythmic) and spectral (pitch) cues contribute to melody recognition, cochlear-implant listeners mostly relied on the rhythmic cues for melody recognition. Without the rhythmic cues, high spectral resolution with as many as 32 bands was needed for melody recognition for normal-hearing listeners. This result indicates that the present cochlear implants provide sufficient spectral cues to support speech recognition in quiet, but they are not adequate to support music perception. Increasing the number of functional channels and improved encoding of the fine structure information are necessary to improve music perception for cochlear implant listeners.