PubMed Health⌕ Search

Biomedical subjects

Yingtian Pan

Publications and source records attributed to Yingtian Pan.

5 recordsLinked to original sources

Dispersion compensation in high-speed optical coherence tomography by acousto-optic modulation.

We report studies of the analyses of and compensation for group dispersion to improve the axial resolution of high-speed optical coherence tomography (OCT) by acousto-optic modulation (AOM). Theoretical modeling and experiments reveal that the high-order group dispersion induced by acousto-optic crystals broadens the measured coherence length (Lc) and thus degrades the axial resolution of OCT imaging. Based on our experimental studies, we can compensate for the dispersion to less than 50% broadening of the source Lc by adjusting the grating-lens-based optical delay in the reference arm and can further eliminate it by inserting like acousto-optic crystals in the sample arm of the OCT system. The results demonstrate that this AOM-mediated OCT system permits high-performance OCT imaging at A-scan rates of as much as 4 kHz by use of a resonant scanner. Because of its ultrastable direct frequency modulation, this AOM-mediated OCT system can potentially improve the performance of high-speed Doppler OCT techniques.

Acoustics↗

Decreasing motion artifacts in calcium-dependent fluorescence transients from the perfused mouse heart using frequency filtering.

A strategy has been developed for the removal of motion artifact and noise in calcium-dependent fluorescence transients from the perfused mouse heart using frequency filtering. An analytical model indicates that the spectral removal of motion artifacts is independent of the phase shift of the motion waveform in the frequency domain, and thus to the time shift (or delay) of motion in the time domain. This is based on the "shift theorem" of Fourier analysis, which avoids erroneous correction of motion artifact when using the motion signal obtained using reflectance from the heart. Several major steps are adopted to implement this model for elimination of motion as well as detection noise from the fluorescence transient signals from the calcium-sensitive probe Rhod-2. These include (1) extracting the fluorescence calcium transient signal from the raw data by using power spectrum density (PSD) in the frequency domain by subtracting the motion recorded using the reflectance of excitation light, (2) digitally filtering out the random noise using multiple bandpass filters centralized at harmonic frequencies of the transients, and (3) extracting high frequency noise with a Gaussian Kernel filter method. The processed signal of transients acquired with excessive motion artifact is comparable to transients acquired with minimal motion obtained by immobilizing the heart against the detection window, demonstrating the usefulness of this technique.

Animals↗

Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers.

Experimental results of a modified micromachined microelectromechanical systems (MEMS) mirror for substantial enhancement of the transverse laser scanning performance of endoscopic optical coherence tomography (EOCT) are presented. Image distortion due to buckling of MEMS mirror in our previous designs was analyzed and found to be attributed to excessive internal stress of the transverse bimorph meshes. The modified MEMS mirror completely eliminates bimorph stress and the resultant buckling effect, which increases the wobbling-free angular optical actuation to greater than 37 degrees, exceeding the transverse laser scanning requirements for EOCT and confocal endoscopy. The new optical coherence tomography (OCT) endoscope allows for two-dimensional cross-sectional imaging that covers an area of 4.2 mm x 2.8 mm (limited by scope size) and at roughly 5 frames/s instead of the previous area size of 2.9 mm x 2.8 mm and is highly suitable for noninvasive and high-resolution imaging diagnosis of epithelial lesions in vivo. EOCT images of normal rat bladders and rat bladder cancers are compared with the same cross sections acquired with conventional bench-top OCT. The results clearly demonstrate the potential of EOCT for in vivo imaging diagnosis and precise guidance for excisional biopsy of early bladder cancers.

Animals↗

Hand-held arthroscopic optical coherence tomography for in vivo high-resolution imaging of articular cartilage.

We describe a novel hand-held polarization optical coherence tomographic (OCT) probe that can be inserted into mammalian joints to permit real-time cross-sectional imaging of articular cartilage. The transverse and axial resolutions of the arthroscopic OCT device are roughly 17 and 10 microm, respectively. Two-dimensional cross-sectional images of cartilage tissue with 500 x 1000 pixels covering an area 6 mm in length and 2.8 mm in depth can be acquired at nearly five frames/s and with over 100 dB of dynamic range. Design of an OCT as a hand-held device capable of providing such an optical biopsy of articular cartilage allows eventual in vivo detection of microstructural changes in articular cartilage that are not apparent using conventional arthroscopic cameras. The OCT probe can be easily incorporated in a conventional arthroscope for cartilage site guidance. The optical arrangement in the OCT scope minimizes specular back-reflection of the probe end face and absorption of body fluid in the path and ensures in-focus OCT imaging when it is in contact with the cartilage specimen to be examined. Successful application of in vivo arthroscopy to porcine articular cartilage demonstrates sufficient resolution and practicality for use in human joints.

Animals↗

Arthroscopic microscopy of articular cartilage using optical coherence tomography.

BACKGROUND: Optical coherence tomography is an echograph of infrared light that can yield microscopic cross-sectional images of articular cartilage without removing or damaging the tissue. HYPOTHESIS: To determine whether optical coherence tomography images of human cartilage can be acquired arthroscopically and whether the resulting images have high correlation with histopathology. METHODS: Optical coherence tomography was configured into an arthroscope and used to image 2 human cadaver knees and 45 cores harvested from 9 osteoarthritic knees. The imaged cartilage was then processed for histological analysis. Optical coherence tomography images and histology were graded using a modified Mankin structural score. Agreement was determined using weighted kappa statistics. Morphometric analysis performed on optical coherence tomography images was correlated with histomorphometric analysis using linear regression. RESULTS: Imaging of the medial and lateral femoral condyles and trochlea was readily accomplished using the optical coherence tomography arthroscope. Modified Mankin surface scores for specimens with the earliest structural changes (grades 0-3) had high agreement with scores assigned to histology (kappa= 0.87). Fibrillation indices calculated from optical coherence tomography had near-perfect correlation to that of histology (R = 0.98) CLINICAL RELEVANCE: Arthroscopic optical coherence tomography may be clinically useful for early detection of articular cartilage injury and nondestructive assessment of articular cartilage repair.

Arthroscopy↗