PubMed Health⌕ Search

Biomedical subjects

Yong-Hong Meng

Publications and source records attributed to Yong-Hong Meng.

2 recordsLinked to original sources

A label-free protein microfluidic array for parallel immunoassays.

A label-free protein microfluidic array for immunoassays based on the combination of imaging ellipsometry and an integrated microfluidic system is presented. Proteins can be patterned homogeneously on substrate in array format by the microfluidic system simultaneously. After preparation, the protein array can be packed in the microfluidic system which is full of buffer so that proteins are not exposed to denaturing conditions. With simple microfluidic channel junction, the protein microfluidic array can be used in serial or parallel format to analyze single or multiple samples simultaneously. Imaging ellipsometry is used for the protein array reading with a label-free format. The biological and medical applications of the label-free protein microfluidic array are demonstrated by screening for antibody-antigen interactions, measuring the concentration of the protein solution and detecting five markers of hepatitis B.

Animals↗

[Application of optical proteinchip in detecting phage M13KO7].

Avidin layer was bound on the substrate surface of Silicon wafer modified with aldehyde. The interaction between avidin and biotin was adopted for the immobilization of mouse monoclonal biotin-anti-M13 (antibody GP3)-labeled biotin. The surface was incubated in a solution containing phage M13KO7, which was trapped by the antibody GP3 with the interaction between phage M13KO7 and antibody GP3, resulting in a variation of layer thickness that was detected by imaging ellipsometry. The results showed a saturated layer of antibody GP3 with a thickness about 6.9 nm on the surface of the silicon wafer. The specific interaction between phage M13KO7 and antibody GP3 resulted in a variation of the layer thickness. The layer of phage M13KO7 bound with antibody GP3 was 17.5 nm in the concentration of 1.1 x 10(10) pfu/mL. Each variation of layer thickness corresponded to a concentration of phage M13KO7 in the range of 0.1 x 10(10) approximately 2.5 x 10(10) pfu/mL, with the sensitivity of 10(9) pfu/mL. Compared with other methods, the optical protein-chip requires only short measurement time, is label free, is a quantitative test, and can be visualized. This study could be significant on the investigation of interactions between the antibody and virus, and shows potential in the early diagnosis of virosis.

Animals↗