PubMed Health⌕ Search

Biomedical subjects

Yoshifumi Fukudome

Publications and source records attributed to Yoshifumi Fukudome.

3 recordsLinked to original sources

[Development of automatic analyses for star-shot images using computed radiography (CR)].

Recent progress in radiation therapy has been greatly enhanced in many facilities by the development of new machines for treatment, improved computer technology for radiotherapy treatment planning systems (RTPs), increased accuracy of radiation therapy such as stereotactic irradiation, and intensity-modulated radiation therapy (IMRT). Quality control (QC) of the isocenter, which has consisted of gantry rotation and limiting the radiation field, is important for greater accuracy of these radiation therapy technologies. Star-shot analyses using computed radiography (CR) for evaluation of the isocenter were employed in this study. Devices to support CR were created, and a method of automatically analyzing images obtained by the star-shot technique, which calculated the error (distance) from the isocenter and the incident beam angle, were developed. In terms of the accuracy of our method, the average maximum error was 0.33 mm (less than 2 pixels: 0.35 mm), the average absolute error and incident beam angle errors were 0.3 mm and 0.4 degrees at maximum and at one standard deviation (SD), respectively. In this study, the processing times were 16 sec at minimum, 152 sec at maximum, 18 sec at most frequencies, and 23.6 sec on average. In conclusion, it was considered that our newly developed method for analyzing star-shot images using CR enabled immediate, quantitative evaluation of the isocenter.

Algorithms↗

[Research on time-course differential imaging by bone scintigraphy].

The temporal image subtraction technique was applied to bone scintigraphy, using Photoshop (commercially available image processing software) and Morpher (public domain warping software). For the temporal subtraction images, 81 subtraction images (19 cases) were prepared by a method used to subtract the previous images from the current ones. Registration of the current and previous images was performed by manual operation using Photoshop, and warping was done using the warping function of Morpher. In addition, difference images prepared after correcting the distributions of radioactive isotopes of the current and previous images using the count of the pelvic region were also examined. Compared with manual operation, alignment of images by warping improved registration and reduced the generation of pseudo-images of subtraction images. The rate of identification of abnormal accumulation-enhanced regions and subjective evaluation by doctors was improved for warping more than for manual operation. Furthermore, abnormal hot regions, which are difficult to find in film images, could be found in three subtraction images. In addition, it was confirmed that abnormal hot regions become more visible in many cases by preparing subtraction images after correcting the count between images using the count of the pelvic region. Thus, it is suggested that the temporal image subtraction technique in bone scintigraphy enables more accurate observation of enhancement of or changes in abnormal hot regions, which will support diagnostic reading. It is considered that enhancement of or changes in abnormal hot regions will be more accurately understood through further detailed discussion in the future.

Bone and Bones↗