PubMed Health⌕ Search

Biomedical subjects

Yoshiharu Namba

Publications and source records attributed to Yoshiharu Namba.

3 recordsLinked to original sources

Wolter type I x-ray focusing mirror using multilayer coatings.

A multilayer coating is a useful addition to a mirror in the x-ray region and has been applied to normal incidence mirrors used with soft x rays. When a multilayer coating is used on grazing incidence optics, higher performance can be achieved than without it. Cr/Sc multilayers coated on a Wolter type I mirror substrate for a soft x-ray microscope are considered. The reflectivity and effective solid angle are calculated for Wolter type I mirrors with uniform and laterally graded multilayer coatings. The laterally graded multilayer mirror showed superior x-ray performance, and the multilayer tolerances were relaxed. This multilayer mirror could be especially useful in the soft x-ray microscope intended for biological applications.

Journal Article↗

Compact soft x-ray transmission microscopy with sub-50 nm spatial resolution.

In this paper, the development of compact transmission soft x-ray microscopy (XM) with sub-50 nm spatial resolution for biomedical applications is described. The compact transmission soft x-ray microscope operates at lambda = 2.88 nm (430 eV) and is based on a tabletop regenerative x-ray source in combination with a tandem ellipsoidal condenser mirror for sample illumination, an objective micro zone plate and a thinned back-illuminated charge coupled device to record an x-ray image. The new, compact x-ray microscope system requires the fabrication of proper x-ray optical devices in order to obtain high-quality images. For an application-oriented microscope, the alignment procedure is fully automated via computer control through a graphic user interface. In imaging studies using our compact XM system, a gold mesh image was obtained with 45 nm resolution at x580 magnification and 1 min exposure. Images of a biological sample (Coscinodiscus oculoides) were recorded.

Diatoms↗

Characterization of the supermirror hard-x-ray telescope for the InFOCmuS balloon experiment.

A hard-x-ray telescope is successfully produced for balloon observations by making use of depth-graded multilayers, or so-called supermirrors, with platinum-carbon (Pt/C) layer pairs. It consists of four quadrant units assembled in an optical configuration with a diameter of 40 cm and a focal length of 8 m. Each quadrant is made of 510 pieces of coaxially and confocally aligned supermirrors that significantly enhance the sensitivity in an energy range of 20-40 keV. The configuration of the telescope is similar to the x-ray telescope onboard Astro-E, but with a longer focal length. The reflectivity of supermirrors is of the order of 40% in the energy range concerned at a grazing angle of 0.2 deg. The effective area of a fully assembled telescope is 50 cm2 at 30 keV. The angular resolution is 2.37 arc min at half-power diameter 8.0 keV. The field of view is 12.6 arc min in the hard-x-ray region, depending somewhat on x-ray energies. We discuss these characteristics, taking into account the figure errors of reflectors and their optical alignment in the telescope assembly. This hard-x-ray telescope is unanimously afforded in the International Focusing Optics Collaboration for muCrab Sensitivity balloon experiment.

Journal Article↗