Highly efficient dynamic modification of plastic microfluidic devices using proteins in microchip capillary electrophoresis.

New dynamic coating agents were investigated for the manipulation of electroosmotic flow (EOF) in poly(methylmethacrylate) (PMMA) microchips. Blocking proteins designed for enzyme-linked immunosorbent assay (ELISA) applications (e.g. Block Ace and UltraBlock), and egg-white lysozyme were proposed in this study. The EOF could be enhanced, suppressed or its direction could be reversed, depending on the buffer pH and the charge on the proteins. The coating procedure is simple, requiring only filling of the microchannels with a coating solution, followed by a rinse with a running buffer solution prior to analysis. One major advantage of this method is that it is not necessary to add the coating agent to the running buffer solution. Block Ace and UltraBlock coatings were stable for at least five runs in a given microchannel without the need to condition the coating between runs other than replenishing the buffer solution after each run, i.e. the RSD values of EOF (n=5) were less than 4.3%, and there was no significant change in the EOF after 5 runs. The reproducibility of the coating procedures was found from the channel-to-channel RSD values of the EOF, and were less than 5.0% when using HEPES-Na buffer (pH 7.4) as the running buffer. Several examples of electrophoretic separations of amino acids and biogenic amines derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) are demonstrated in this paper. The dynamic coating method has the potential for a broad range of applications in microchip capillary electrophoresis (microchip CE) separations.

Amphetamine↗

High-throughput nitric oxide assay in biological fluids using microchip capillary electrophoresis.

In order to develop a high-throughput screening method for the nitrogen monoxide metabolites, nitrite and nitrate, in biological fluids, we have investigated the simultaneous determination of these metabolites using microchip capillary electrophoresis (MCE). In this study, the control of applied voltage to obtain higher sensitivity by increasing the sample injection volume was investigated. Also, the improvement of reproducibility by correcting the injection volume using the internal standard was investigated. By increasing the sample volume, the limits of detection achieved for nitrite and nitrate were 24 and 12 microM, respectively. Because we used a 10-fold diluted sample when detecting nitrite and nitrate in human serum, it was necessary to increase the sensitivity by a factor of 10-50. The run-to-run and day-to-day relative standard deviations achieved were improved to less than 10% by using an internal standard to correct the injection volume. Moreover, we obtained successful separation of nitrite and nitrate in spiked human serum within 6.5 s under optimum analytical conditions. As a result, although it is necessary to obtain greater sensitivity, it was concluded that determination of the amount of NO metabolites in biological fluids using MCE is possible.

Calibration↗

Development of an analytical method using microchip capillary electrophoresis for the measurement of fluorescein-labeled salivary components in response to exercise stress.

We have developed an analytical method using microchip capillary electrophoresis (microchip CE) for the high-speed separation of fluorescein-labeled salivary components in response to exercise stress. Optimal separation was obtained using a borate buffer at pH 9.5 containing 10 mM beta-cyclodextrin and 1.0% (w/v) methylcellulose. To minimize individual differences in human saliva, such as viscosity, conductivity, and contaminants, the concentration of methylcellulose in the analytical conditions played a key factor. The optimized separation conditions produced identical electropherograms successfully despite of the use of different microchips made from quartz glass or poly-methylmethacrylate (PMMA). In addition, a practical application of bicycle ergometer stress was performed. Some components in human saliva showed a marked decrease after exercise stress.

Electrophoresis, Microchip↗

The role of von Hippel-Lindau protein in the differentiation of neural progenitor cells under normoxic and anoxic conditions.

Von Hippel-Lindau protein (pVHL) normally functions to cause ubiquitin-mediated degradation of hypoxia-inducible factor-1alpha (HIF-1alpha) under normoxic but not under hypoxic conditions, and induces neuronal differentiation of neural progenitor cells. However, the role of pVHL in the differentiation of neural progenitor cells under either condition has not been fully elucidated. Herein, we show that under the anoxic condition the expression of pVHL and neuronal markers in neural progenitor cells was inhibited, while HIF-1alpha was induced. In addition, neural progenitor cells expressing pVHL following gene transfer showed distinct neuronal differentiation and no induction of HIF-1alpha under the normoxic condition but not under the anoxic condition. In conclusion, neuronal differentiation induced by pVHL is associated with degradation of HIF-1alpha and occurs normally under the normoxic condition but not under the anoxic condition. Differentiation of neuronal progenitor cells may thus depend on oxygen density.

Animals↗

Simultaneous separation and on-line concentration of amitrole and benzimidazole pesticides by capillary electrophoresis with a volatile migration buffer applicable to mass spectrometric detection.

This study used capillary electrophoresis (CE) to investigate the simultaneous separation and on-line concentration of five pesticides: amitrole (AMT), carbendazim (MBC), 2-aminobenzimidazole (ABI), thiabendazole (TBZ) and 1,2-diaminobenzene (DAB). A volatile migration buffer was used for the investigation because of the applicability to mass spectrometric (MS) detection. They were separated completely at pH 4.0 as a result of changing pH using formic acid-ammonium formate buffer. Values of the dissociation constant for MBC and DAB estimated from the changes in the mobility with pH showed good agreement with values in the literature. Dissociation constants for AMT and TBZ were estimated. Limits of detection (LODs) for the analytes were on the ppm level with UV detection under the optimized separation condition. On-line concentration by simple stacking mode was not effective except to 2-aminobenzimidazole because of the peak tailing. The addition of formic acid to sample matrix improved the peak shapes. That improvement may be attributed to transient isotachophoretic effect. The concentration factors obtained from the comparison of the LODs were in the range of 7.6-27-fold. This concentration method was applied preliminarily to CE with MS detection.

Amitrole↗

Simultaneous determination of nitrate and nitrite in biological fluids by capillary electrophoresis and preliminary study on their determination by microchip capillary electrophoresis.

In order to develop a highly sensitive and high-throughput screening method for nitrogen monoxide metabolites in biological fluids, we have investigated the simultaneous determination of nitrite and nitrate, using capillary electrophoresis and microchip capillary electrophoresis. In capillary zone electrophoresis, a running buffer based on human serum components with high ionic strength has been developed for the determination of nitrite and nitrate in human serum and human saliva. We obtained successful separation of nitrite and nitrate in the serum and the saliva within 7 min under optimum analytical conditions. Linear calibration curves for nitrite and nitrate for both peak height and area were obtained by a standard addition method. The limits of detection obtained at a signal-to-noise ratio (S/N) of 3 for nitrite and nitrate in the serum were 2.6 and 1.5 microM, respectively. The values of the relative standard deviation of peak height for the serum with 9.2 microM nitrite and 20.9 microM nitrate were 5.7 and 4.1%, respectively. For on-site analysis with high-throughput screening, a microchip capillary electrophoresis method using a microchip made of quartz with a UV detector was developed. In this high-throughput format, using a running buffer with an electroosmotic flow modifier, the peaks of nitrite and nitrate in an artificial serum sample were obtained within 8 s. In high-resolution mode, using the buffer without electroosmotic flow modifier, the separation of nitrite and nitrate was obtained within 15 s. In high-resolution mode, using an artificial serum sample with 50 microM NO2- and 50 microM NO3-, the limits of detection (S/N = 3) of 41 microM for NO2- and 26 microM for NO3- were obtained. The method was applied to human serum and saliva. We obtained peaks due to nitrite and nitrate in 10-fold diluted saliva.

Electrochemistry↗

Simultaneous determination of nitrite, nitrate, thiocyanate and uric acid in human saliva by capillary zone electrophoresis and its application to the study of daily variations.

Simultaneous determination of nitrite (NO2-), nitrate (NO3-), thiocyanate (SCN-) and uric acid in human saliva was performed by capillary zone electrophoresis using a coated capillary with reversed electroosmotic flow (EOF), using a 100 mM sodium phosphate buffer at pH 6.5 as a running buffer. Saliva samples were deproteinized with acetonitrile and filtered through a membrane filter. The important advantages of the reported method are: simple operation, short analysis time, minimal sample pre-treatment and sample dilution. In order to evaluate the daily variations of the anionic components, the concentrations were determined in the human saliva of four healthy volunteers upon waking and at 2qh intervals during a day.

Circadian Rhythm↗

Evaluation of an atmospheric pressure chemical ionization interface for capillary electrophoresis-mass spectrometry.

A simple and inexpensive approach to modify a commercial atmospheric pressure chemical ionization (APCI) interface was proposed for capillary electrophoresis-mass spectrometry (CE-MS). In order to accommodate lower flow rates in the range 1-10 microl/min, both sheath liquid and nebulizing gas were coaxially supplied to the nebulizer as an arrangement of pneumatically assisted electrospray interface. Since this paper focused on the primary study of the modified APCI interface, the performance of the interface was first evaluated by the direct infusion of a reserpine solution. Optimization of several APCI parameters, such as temperature of APCI vaporizer, nebulizing gas flow and APCI corona discharge current, were accomplished. The orifice dimension for the nebulizing gas flow was largely independent of the MS sensitivity when the nebulizing gas flow rate was ca. 0.4 l/min. A successful CE-APCI-MS separation is obtained using the modified APCI interface.

Atmospheric Pressure↗

Estimation of binding constants by capillary electrophoresis.

Capillary electrophoresis (CE) has become a useful technique for measuring binding constants. This review is focused on recent trends in the estimation of binding constants by affinity CE. First, we introduce several mathematical equations in which it is assumed that the stoichiometry of the binding between drug and protein is 1:1 as a simple model. In order to calculate accurate binding constants by affinity CE, several experimental considerations are described in this review. In addition, some recent methodologies, such as partial filling technique and multiple-step ligand injection method, are introduced. Among research publications within 3 years, recent applications for determining binding constants are reviewed.

Electrophoresis, Capillary↗

Method development of enantiomer separations by affinity capillary electrophoresis, cyclodextrin electrokinetic chromatography and capillary electrophoresis-mass spectrometry.

Capillary electrophoresis (CE) has become a powerful tool for enantiomer separations during the last decade. Since 1993, the author has investigated enantiomer separations by affinity capillary electrophoresis (affinity CE) with some proteins and by cyclodextrin electrokinetic chromatography (CDEKC) with some charged cyclodextrins (CDs). Many successful enantiomer separations are demonstrated from our study in this review article. In the enantiomer separations by affinity CE, the deterioration of detection sensitivity was observed under high concentration of the protein in running solutions. The partial filling technique was practically useful to solve the serious problem. It allowed operation at high protein concentrations, such as 500 mumol/L, without the detection problem. Charged CDs had several advantages for the enantiomer separations over neutral ones. Strong electrostatic interactions between a charged CD and oppositely charged analytes should be effective for the formation of the complex. A large difference in electrophoretic mobility between the free analyte and the inclusion complex should also enhance the enantiomeric resolution. In CE-mass spectrometry (CE-MS), the partial filling technique was applied to avoid the introduction of nonvolatile chiral selectors into the CE-MS interface. By replacing the nonvolatile electrolytes in the running buffer by volatile ones, the separation conditions employed in CE with the UV detection method could be transferred to CE-MS.

Chromatography, Micellar Electrokinetic Capillary↗