PubMed Health⌕ Search

Biomedical subjects

Yoshihide Tatsumi

Publications and source records attributed to Yoshihide Tatsumi.

6 recordsLinked to original sources

Initial experience with a new peroral electronic pancreatoscope with an accessory channel.

BACKGROUND: A peroral electronic pancreatoscope was previously developed to improve visualization of the pancreatic duct, but this instrument had no accessory channel. METHODS: A new peroral electronic pancreatoscope (2.6-mm external diameter) with an accessory channel (0.5 mm) was developed. Peroral pancreatoscopy or cholangioscopy was performed with this new instrument in 11 patients with various pancreatobiliary diseases. The clinical utility of the new peroral electronic pancreatoscope was assessed, and visualization with this new instrument was compared with that of the prototype. RESULTS: The resolution of the two instrument systems was nearly equal, with that provided by the new peroral electronic pancreatoscope being slightly better. The new peroral electronic pancreatoscope was inserted successfully into the pancreatic or bile duct in 9 of the 11 patients (82%). Observation of a predetermined target and juice collection with direct visualization was successful in 8 of the 9 patients (89%). CONCLUSIONS: The new peroral electronic pancreatoscope with an accessory channel was useful for clinical diagnosis of various pancreatobiliary diseases. Visualization is excellent. Pancreatic juice and other samples can be collected under direct visualization.

Aged↗

Effect of Helicobacter pylori eradication on gastroesophageal function.

BACKGROUND: To elucidate the cause of possible occurrence of reflux esophagitis after Helicobacter pylori eradication, gastric and esophageal function among H. pylori infected Japanese patients were evaluated both before and after eradication therapy. METHODS: Nine H. pylori-positive patients were studied before and 6 months after successful H. pylori eradication. Studies included gastric emptying, esophageal manometry, gastric and esophageal pH monitoring as well as measuring serum levels of gastrin, pepsinogen I and pepsinogen II. RESULTS: Helicobacter pylori eradication was associated with a significant change in serum gastrin and pepsinogen levels, consistent with the improvement in mucosal inflammation. There was no significant change in gastric emptying, fasting or postprandial lower esophageal sphincter (LES) pressure, esophageal primary peristaltic contractions, frequency of transient LES relaxation, or gastroesophageal reflux, as assessed by 24 h pH monitoring. The percent time of the gastric pH>4 at night decreased significantly. A 41-year-old male developed erosive gastroesophageal reflux disease (GERD) (Los Angeles Classification Grade A) after eradication. Physiological studies showed he had abnormal esophageal motility prior to H. pylori eradication. CONCLUSIONS: With the exception of gastric pH at night, most patients did not experience a significant change in gastric or esophageal function after H. pylori eradication. Development of GERD post H. pylori eradication likely reflects an increase in the acidity of the refluxate superimposed on pre-existing abnormalities in gastroesophageal motility.

Adult↗

Direct cholangioscopy and pancreatoscopy.

Direct cholangiopancreatoscopy has played a minor role in the diagnosis and treatment of pancreaticobiliary disorders, initially because of instrument fragility and suboptimal imaging, and later because of improvements in noninvasive and semi-invasive imaging techniques. Digital scopes provide superior images and hold the promise of increased application and improved durability.

Bile Ducts↗

Electronic pancreatoscopy for the diagnosis of pancreatic diseases.

OBJECTIVES: Diagnostic pancreatoscopy was performed in 56 patients using the newly developed peroral electronic pancreatoscope (PEPS). The diagnostic value of the PEPS for pancreatic diseases was evaluated. METHODS: The PEPS (external diameter = 2.1 mm, bidirectional tip deflection) was developed with a minute 50,000-pixel interline charge-coupled device. Pancreatoscopy was performed by means of an endoscopic retrograde approach without sphincterotomy. The cases examined were normal (three), chronic pancreatitis (32), pancreatic cancer (eight), and intraductal papillary mucinous tumors (13). RESULTS: Of the 56 cases, 42 (75%) were adequately seen. In normal cases, fine capillary vessels were clearly visualized on the smooth whitish-pink mucosa. Findings in chronic pancreatitis included protein plugs, calcified stones, rough whitish mucosa, scar formation, edema, erythema, and indistinct capillary appearance. All the stenoses of chronic pancreatitis could be differentiated from those of pancreatic cancer with the PEPS. In the pancreatic cancer cases, all patients had stenoses or duct cutoffs; most cases had friable mucosa with erythema and erosive changes, and a single patient had a compressed pancreatic duct wall covered with normal epithelium. In the cases of intraductal papillary mucinous tumors, papillary tumors were visualized with extreme clarity. In the case of adenocarcinoma, the PEPS revealed oval-shaped tumors with spotty redness or villous tumors with dilation of capillary vessels. Moderate acute pancreatitis was recognized after pancreatoscopy in one of the 56 cases (1.8%). CONCLUSIONS: Electronic pancreatoscopy with the PEPS is feasible in most patients and technically safe, and improves diagnostic yield over conventional pancreatoscopy.

Electronics, Medical↗