Selective detection method derived from a controlled diffusion process at metal-modified diamond electrodes.

A novel, selective methodology is derived based on the difference between the diffusion processes at microelectrodes (i.e., hemispherical diffusion) and the macroelectrode (i.e., linear diffusion) in a metal-implanted boron-doped diamond electrode (metal-BDDs). As an example, the selective detection of glucose in a solution containing interference species such as ascorbic acid and uric acid is demonstrated. The electrochemical properties of BDD, which are low background current, extremely high stability, and (especially) inactivity toward glucose, play an important role in realizing these differences in the diffusion characteristics. The present methodology can be applied not only to selective glucose detection by the metal-BDD system but also to other selective detection systems.

Ascorbic Acid↗

Electrochemical detection of arsenic(III) using iridium-implanted boron-doped diamond electrodes.

Iridium-modified, boron-doped diamond electrodes fabricated by an ion implantation method have been developed for electrochemical detection of arsenite (As(III)). Ir+ ions were implanted with an energy of 800 keV and a dose of 10(15) ion cm(-2). An annealing treatment at 850 degrees C for 45 min in H2 plasma (80 Torr) was required to rearrange metastable diamond produced by an implantation process. Characterization was investigated by SEM, AFM, Raman, and X-ray photoelectron spectroscopy. Cyclic voltammetry and flow injection analysis with amperometric detection were used to study the electrochemical reaction. The electrodes exhibited high catalytic activity toward As(III) oxidation with the detection limit (S/N = 3), sensitivity, and linearity of 20 nM (1.5 ppb), 93 nA microM(-1) cm(-2), and 0.999, respectively. The precision for 10 replicate determinations of 50 microM As(III) was 4.56% relative standard deviation. The advantageous properties of the electrodes were its inherent stability with a very low background current. The electrode was applicable for analysis of spiked arsenic in tap water containing a significant amount of various ion elements. The results indicate that the metal-implanted method could be promising for controlling the electrochemical properties of diamond electrodes.

Arsenites↗