PubMed Health⌕ Search

Biomedical subjects

Yoshihisa Katayose

Publications and source records attributed to Yoshihisa Katayose.

4 recordsLinked to original sources

Intraoperative sentinel lymph node mapping using a new sterilizable magnetometer in patients with nonsmall cell lung cancer.

PURPOSE: We recently developed a novel method for sentinel lymph node mapping using magnetic force. However, problems with the sterility and sensitivity of the magnetometer made intraoperative sentinel lymph node mapping impossible. The purpose of this study was to test the utility of a new, more sensitive, sterilizable magnetometer developed in our institute for in vivo sentinel lymph node mapping in patients with nonsmall cell lung cancer. DESCRIPTION: Ferumoxides (magnetite) served as the tracer. Twenty patients with nonsmall cell lung cancer participated in the study. Each received 5 mL of ferumoxides, which were injected around their tumor. Magnetic force was then measured intraoperatively using the new sterilizable magnetometer. EVALUATION: The in vivo sentinel lymph node detection rate was 80.0% (16 of 20). The accuracy, sensitivity, and false-negative rates were 100% (16 of 16), 100% (4 of 4) and 0% (0 of 12), respectively. Our preliminary study indicates that our new magnetometer enables in vivo sentinel lymph node mapping in patients with nonsmall cell lung cancer. CONCLUSIONS: This device safely and accurately detected sentinel lymph nodes in nonsmall cell lung cancer patients.

Aged↗

Superior mediastinal and neck lymphatic mapping in mid- and lower-thoracic esophageal cancer as defined by ferumoxides-enhanced magnetic resonance imaging.

OBJECTIVE: The purpose of this study was to detect lymphatic drainage into the superior mediastinum and neck in thoracic esophageal cancer patients using ferumoxides-enhanced magnetic resonance imaging (MRI), and to have this information assist in determining the appropriate extent of lymphadenectomy. METHODS: Nine male patients with T2-T3 mid- and lower-thoracic esophageal cancer with lymph node metastasis were examined. The day before surgery, ferumoxides was endoscopically injected into the submucosal layer of the peritumoral lesion. Thereafter, lymph nodes in the superior mediastinum and neck, which were shown to be ferumoxides-enhanced on MRI, were harvested and evaluated; magnetic force from all harvested lymph nodes was measured ex vivo. RESULTS: MRI of the superior mediastinum and neck revealed 1(median) ferumoxides-enhanced lymph nodes in eight (89%) patients, and there was laterality in the lymphatic mapping in both areas. Of the 15 lymph nodes into which drainage was detected by enhanced MRI, 12 (80%) were magnetite-positive. In six patients (67%), magnetic resonance enhanced lymph nodes corresponded completely with the ex vivo magnetite examination, and in 3 patients (33%) there was partial agreement. In 3 (60%) of the 5 patients that showed paratracheal and/or supraclavicular lymph node metastases, all of the affected nodes were detected by MRI; in one patient some of the affected nodes were detected. CONCLUSION: Ferumoxides-enhanced MRI is useful for visualizing lymphatic drainage to the superior mediastinum and neck in thoracic esophageal cancer. It is an adequate procedure to form an estimate on the appropriate extent of lymphadenectomy.

Adult↗

A novel method for sentinel lymph node mapping using magnetite in patients with non-small cell lung cancer.

OBJECTIVE: The detection rate of sentinel lymph nodes in patients with non-small cell lung cancer using isosulfan blue dye is too low for clinical use. Although exposure to radioactivity is reportedly minimal, special procedures are nonetheless required when a radioactive isotope is used as a tracer. Therefore, to eliminate the need for a radioactive tracer and to obtain a better detection rate than is obtained with isosulfan blue dye, we have developed a novel method that employs magnetite as the tracer. The aim of the present study was to test the feasibility of this technique. METHODS: The tracer employed was ferumoxides, a colloidal superparamagnetic iron oxide of nonstoichiometric magnetite. Thirty-eight non-small cell lung cancer patients participated in the study; each received 5 mL of ferumoxides, injected around the tumor intraoperatively. Fifteen minutes after injection, lung resection and lymph node dissection were carried out. The magnetic force within the lymph nodes was measured using a highly sensitive handheld magnetometer ex vivo. All lymph nodes were also subjected to conventional histological analysis. RESULTS: The rate of detection of sentinel lymph nodes was 81.6% (31/38). The accuracy, sensitivity, and false-negative rates were 96.8% (30/31), 85.7% (6/7), and 14.3% (1/7), respectively. CONCLUSION: Intraoperative sentinel lymph node mapping using ferumoxides and a highly sensitive magnetometer is a safe, accurate, and sensitive way to detect sentinel lymph nodes in non-small cell lung cancer patients.

Adult↗

[Sentinel lymph node after intramammary injection of superparamagnetic iron oxide].

The purpose of this study was to evaluate enhancement (signal loss) of the axillary lymph nodes on MR lymphography after intramammary injection of superparamagnetic iron oxide (Ferumoxides) for detection of the sentinel lymph node. MR lymphography was performed in a total of 11 patients with breast cancer without palpable axillary lymph node swelling before operation. Coronal and axial images were obtained before and after intramammary injection of 1.5 ml Ferumoxides adjacent to the breast tumor. In all patients, decreased intensity was recognized in the axillary lymph nodes. MR lymphography could detect the sentinel lymph node with its decreased signal intensity 20 minutes after the intramammary injection of Ferumoxides.

Axilla↗