Static and dynamic analysis of five anterior instrumentation systems for thoracolumbar scoliosis.

STUDY DESIGN: A nondestructive biomechanical investigation among five anterior spinal instrumentation systems for scoliosis. OBJECTIVES: The purpose of this study is to analyze the static and dynamic biomechanical stability of five different systems. SUMMARY OF BACKGROUND DATA: Although a variety of anterior spinal instrumentation systems for scoliosis are available, very few attempts have been made at comparative biomechanical studies. METHODS: Thirty calf spines were underwent static biomechanical tests, including flexion-extension, axial rotation, and lateral bending loading modes in the multisegmental spinal model. Five anterior instrumentation systems included: 1) Texas Scottish Rite Hospital system; 2) Bad Wildungen Metz; 3) anterior ISOLA; 4) Cotrel-Dubousset Hoph; and 5) Kaneda Anterior Scoliosis System. The initial and postfatigue stability after a cyclic loading test were analyzed by measuring the range of motion at instrumented segments compared to the intact within the same specimen (% to intact). RESULTS: Two-rod systems showed a significant decrease in range of motion compared to one-rod systems in flexion-extension (P < 0.001) and axial rotation (P < 0.05). In lateral bending, all systems demonstrated a significant decrease in range of motion of less than 40% to the intact (P < 0.001). After cyclical loading test, all systems increased in range of motion. In flexion-extension, one-rod systems depicted a significant increase in range of motion, compared to two-rod systems (P < 0.05). CONCLUSIONS: In the initial stability analysis, two-rod systems are superior to one-rod systems. For one-rod systems, repeated physiologic loading may result in reduced stability in flexion-extension.

Analysis of Variance↗

Bone ingrowth fixation of artificial intervertebral disc consisting of bioceramic-coated three-dimensional fabric.

STUDY DESIGN: The bone-bonding characteristic of the new artificial intervertebral disc consisting of bioceramic-coated three-dimensional fabric was evaluated mechanically and histologically in an in vivo sheep model. OBJECTIVES: To investigate the mechanical properties and the histologic appearance of the interface between the three-dimensional fabric disc and the vertebral body, and to evaluate these alterations in vivo under a spinal segmentally mobile condition. SUMMARY OF BACKGROUND DATA: Bone ingrowth to the bioceramic-coated three-dimensional fabric surface had been demonstrated already under a stable environment in preliminary animal studies. METHODS: For this study, 20 sheep underwent two-level lumbar intervertebral disc replacement with three-dimensional fabric discs (Group I) or bioceramic spacers as a comparative material (Group II). All operative segments were stabilized temporarily with spinal instrumentation for the initial ingrown phase. Four animals each were killed at 4, 6, 15, and 24 months in Group I and at 6 months in Group II, and the operative segments were subjected to either a detachment test or histologic evaluation. RESULTS: The interfacial tensile strength at 6 months was significantly higher in Group I than in Group II. No significant decrease in tensile strength was detected until 24 months after surgery in Group I. Histologically, bone ingrowth to the three-dimensional fabric surface was observed 4 months after surgery, and no aseptic loosening occurred until 24 months after surgery. CONCLUSIONS: The findings show that the three-dimensional fabric disc was firmly fixed to the vertebral body by bone ingrowth, and that this biologic fixation was preserved even under the spinal segmentally mobile condition.

Animals↗

Diagnostic accuracy of magnetic resonance imaging for detecting posterior ligamentous complex injury associated with thoracic and lumbar fractures.

OBJECT: The posterior ligamentous complex (PLC) in the thoracic and lumbar spine is one of the region's important stabilizers. The precise diagnosis of PLC injury is required to evaluate the instability of the injured spine; however, the accuracy of magnetic resonance (MR) imaging for diagnosing PLC injury has remained unclear. In this study, the authors compared preoperative MR imaging findings with direct intraoperative observation of PLC injury, clarifying the former's diagnostic accuracy regarding detection of PLC injury associated with the thoracic and lumbar fractures. METHODS: Data obtained in 35 patients who sustained thoracic or lumbar injuries were reviewed. There were 17 burst fractures, six flexion-distraction injuries, and 12 fracture dislocations. Each patient underwent MR imaging examination within 3 weeks of injury. Three radiologists independently evaluated sagittal MR images in a blinded fashion. The PLC-related information was retrospectively collected from each operative record. The diagnostic accuracy of MR imaging was analyzed by comparing imaging-documented intraoperative findings. The PLC injuries were detected in 23 patients (65.7%) by direct observation during posterior spinal procedures. The diagnostic accuracy of MR imaging in detecting injury of the supraspinous ligament (SSL) and interspinous ligament (ISL) was 90.5 and 94.3%, respectively. The specificity of T1-weighted MR imaging alone for depicting the SSL was significantly greater than T2-weighted imaging alone (p < 0.05). The overall mean kappa coefficient for MR imaging findings of PLC injury was 0.803, which indicated excellent interobserver reliability; that for ISL (0.915) was significantly greater than that for SSL (0.69) (p < 0.05). CONCLUSIONS: This study clarified a high diagnostic accuracy and interobserver reliability of MR imaging for PLC injury. The precise diagnosis of PLC injury is essential to determine the mechanical instability of the injured thoracic and lumbar spine, especially in differentiating unstable (three-column) burst fractures from the relatively stable (two-column) type. The authors conclude that MR imaging is a powerful diagnostic tool to evaluate PLC injury associated with thoracic and lumbar fractures.

Humans↗

In vitro biomechanical effects of reconstruction on adjacent motion segment: comparison of aligned/kyphotic posterolateral fusion with aligned posterior lumbar interbody fusion/posterolateral fusion.

OBJECT: Posterior lumbar interbody fusion (PLIF) was developed to overcome the limitations of posterolateral fusion in correcting spinal deformity and maintaining lumbar lordosis. In this study the authors compare the biomechanical effects of three different posterior reconstructions on the adjacent motion segment. METHODS: Ten calf spinal (L2-S1) specimens underwent nondestructive flexion-extension testing (+/- 6 Nm). The specimens were destabilized at the L5-S1 levels after intact testing. This was followed by pedicle screw fixation with and without interbody cages as follows: 1) with straight rods ("aligned" posterolateral fusion); 2) with kyphotically prebent rods ("kyphotic" posterolateral fusion); and 3) with interbody cages combined with straight rods ("aligned" PLIF/posterolateral fusion). The range of motion (ROM) of the operative segments, the intradiscal pressure (IDP), and longitudinal lamina strain in the superior adjacent segment (L4-5) were analyzed. The ROM associated with aligned PLIF/posterolateral fusion-treated specimens was significantly less than both the aligned and kyphotic posterolateral fusion-treated procedures in both flexion and extension loading (p < 0.05). The aligned PLIF/posterolateral fusion was associated with greater IDP and the lamina strain compared with the aligned and kyphotic posterolateral fusion groups in flexion loading. Under extension loading, greater IDP and lamina strain were present in the kyphotic posterolateral fusion group than in the aligned posterolateral fusion group. The highest IDP and lamina strain were shown in the aligned PLIF/posterolateral fusion group. CONCLUSIONS: Compared with kyphotic posterolateral fusion, PLIF may lead to even higher load at the superior adjacent level because of the increased stiffness of the fixed segments even if local kyphosis is corrected by PLIF.

Animals↗

Artificial intervertebral disc replacement using bioactive three-dimensional fabric: design, development, and preliminary animal study.

STUDY DESIGN: A new artificial intervertebral disc was developed, and its intrinsic biomechanical properties, bioactivity, and the effectiveness as a total disc replacement were evaluated in vitro and in vivo. OBJECTIVES: To introduce a new artificial intervertebral disc and to evaluate the in vitro mechanical properties, fusion capacity to bone, and segmental biomechanics in the total intervertebral disc replacement using a sheep lumbar spine. SUMMARY OF BACKGROUND DATA: The loss of biologic fusion at the bone-implant interface and prosthetic failures have been reported in previous artificial discs. There have been no clinically applicable discs with detailed experimental testing of in vivo mechanics and interface fusion capacity. METHODS: The artificial intervertebral disc consists of a triaxial three-dimensional fabric (3-DF) woven with an ultra-high molecular weight polyethylene fiber, and spray-coated bioactive ceramics on the disc surface. The arrangement of weave properties was designed to produce mechanical behavior nearly equivalent to the natural intervertebral disc. Total intervertebral disc replacement at L2-L3 and L4-L5 was performed using 3-DF disc with or without internal fixation in a sheep lumbar spine model. The segmental biomechanics and interface histology were evaluated after surgery at 4 and 6 months. RESULTS: The tensile-compressive and torsional properties of prototype 3-DF were nearly equivalent to those of human lumbar disc. The lumbar segments replaced with 3-DF disc alone showed a significant decrease of flexion-extension range of motion to 28% of control values as well as partial bony fusion at 6 months. However, the use of temporary fixation provided a nearly physiologic mobility of the spinal segment after implant removal as well as excellent bone-disc fusion at 6 months. CONCLUSION: An artificial intervertebral disc using a three-dimensional fabric demonstrated excellent in vitro and in vivo performance in both biomechanics and interface histology. There is a potential for future clinical application.

Animals↗

Complications related to hydroxyapatite vertebral spacer in anterior cervical spine surgery.

STUDY DESIGN: This is a report of complications related to the hydroxyapatite vertebral spacer used for anterior cervical reconstructive surgery. Compression of the spinal cord by broken fragments of hydroxyapatite spacer as well as its surrounding radiolucent clear zone were observed in seven patients. OBJECTIVES: To report complications related to the use of hydroxyapatite vertebral spacer for anterior cervical reconstructive surgery and to discuss how to prevent these complications. SUMMARY OF BACKGROUND DATA: Despite previous articles reporting the clinical applications of hydroxyapatite vertebral spacer for the cervical spine, clinical reports regarding the long-term results of hydroxyapatite spacer for anterior cervical surgery and its complications have been limited. METHODS: The authors reviewed patients who underwent anterior reconstructive surgery using the hydroxyapatite spacer at other hospitals and had postoperative complications related to hydroxyapatite spacer. RESULTS: Seven patients previously treated by anterior cervical spine surgery using the hydroxyapatite vertebral spacer were referred to the authors because of unsatisfactory surgical outcomes. All the patients had a radiolucent clear zone around the spacer and experienced severe neck pain. Four had fracture of the hydroxyapatite spacer, and two had compression of the spinal cord by retropulsed fragments of broken hydroxyapatite spacers. CONCLUSIONS: Although hydroxyapatite has been used in many medical fields because of its bioactive characteristics, its mechanical properties should be improved to lessen the risks of breakage and subsequent spinal cord compression. Gentle insertion maneuvers are also important to avoid the production of cracks inside the spacer.

Aged↗

Spinal cord compression by multistrand cables after solid posterior atlantoaxial fusion. Report of three cases.

The sublaminar wiring procedure has been commonly used for stabilizing the atlantoaxial complex. Multistrand braided cables were introduced in the early 1990s. In previous biomechanical studies these cables were demonstrated to be superior to monofilament wires in terms of their flexibility, mechanical strength, and fatigue-related characteristics. To the authors' knowledge, they are the first to describe clinically the occurrence of delayed spinal cord compression resulting from multistrand cables after the completion of rigid spinal arthrodesis in the upper cervical spine. Three patients underwent posterior atlantoaxial fusion in which two sublaminar multistrand cables were placed. Between 15 and 48 months postoperatively, they suffered from upper- and lower-extremity numbness as well as gait disturbance. Plain radiography and computerized tomography myelography revealed spinal cord compression caused by the sublaminar cables, although fusion was complete and physiological alignment was maintained at the fused segment. The radiographs obtained immediately after surgery demonstrated that the initial cable placement had been properly performed. The shape of the cable at the initial surgery was oval and then gradually became circular. The anterior arc of the circular shape of the cable in fact led to the spinal cord compression. Considering the mechanism of this late complication, a cable tends to spring open because of its high flexibility and becomes circular shaped even after the complete arthrodesis. When applying multistrand cables for intersegmental fixation at the atlantoaxial complex, delayed complications related to bowing of the cables is possible.

Adult↗