PubMed Health⌕ Search

Biomedical subjects

Yoshikuni Kikutani

Publications and source records attributed to Yoshikuni Kikutani.

11 recordsLinked to original sources

Microchip-based liquid-liquid extraction for gas-chromatography analysis of amphetamine-type stimulants in urine.

A microchip-based liquid-liquid extraction for the gas chromatography analysis of urine for amphetamine-type stimulants has been developed. Partially modified microchannels with the capillarity restricted modification (CARM) method were employed for stabilizing the interface consisting of 1-chlorobutane and alkalized urine. Reliability of the microchip-based extraction was evaluated with respect to linearity, trueness and precision. As a practical demonstration, methoxyphenamine hydrochloride (50 mg) was administered to three healthy volunteers, and the concentration of methoxyphenamine in their urine was determined by both methods for comparison. This study showed the potential of pressure-driven microfluidics to contribute to the rapid automation analysis in forensic toxicology.

Adult↗

Surface modification method of microchannels for gas-liquid two-phase flow in microchips.

A capillarity restricted modification method for microchannel surfaces was developed for gas--liquid microchemical operations in microchips. In this method, a microstructure combining shallow and deep microchannels and the principle of capillarity were utilized for chemical modification of a restricted area of a microchannel. A hydrophobic--hydrophilic patterning in microchannels was prepared as an example for guiding gas and liquid flows along the respective microchannels. Validity of the patterning was confirmed by measuring aqueous flow leak pressure from the hydrophilic microchannel to the hydrophobic one. The leak pressure of 7.7-1.1 kPa agreed well with that predicted theoretically from the Young-Laplace equation for the microchannel depth of 8.6-39 microm. In an experiment to demonstrate usefulness and effectiveness of the method, an air bubble was first introduced into the hydrophilic microchannel and purged from the hydrophobic-hydrophilic patterned microchannels. Next, the patterning structure was applied to remove dissolved oxygen by contacting the aqueous flow with a nitrogen flow. The concentration of dissolved oxygen decreased with contact time, and its time course agreed well with numerical simulation. These demonstrations showed that the proposed patterning method can be used in general microfluidic gas-liquid operations.

Biomechanical Phenomena↗

Optimization of an interface chip for coupling capillary electrophoresis with thermal lens microscopic detection.

This paper presents a capillary-to-microchip connection, which can be used as an interface for coupling capillary electrophoresis (CE) with a thermal lens microscope (TLM). It is difficult to directly apply TLM to samples in a capillary with a curved surface, and such an interface chip at the end of a CE separation column is needed for reliable TLM measurements. The dependence of the TLM signal intensity on the TLM detection point in the interface chip and the dependence of the theoretical plate number of CE separation on the channel dimensions of the interface chip were investigated and optimized with a mixture of 4-dimethylaminoazobenze-4'-sulfonyl (DABSYL)-derivatized amino acids (glycine, alanine, methionine, and proline) as a model sample. By using an optimized interface chip, theoretical plate numbers of DABSYL-glycine, -methionine, -alanine, and -proline were obtained to be 104000, 95000, 104000, and 95000, respectively.

Amino Acids↗

Grazing-exit and micro X-ray fluorescence analyses for chemical microchips.

Grazing-exit x-ray fluorescence (GE-XRF) and micro x-ray fluorescence (micro-XRF) methods were applied to chemical microchips as a detection method. Since an energy-dispersive x-ray detector was used, the simultaneous detection of multiple elements was possible. An analyzing region was especially designed on the microchip so that a sample solution could be dried and concentrated in a suitable area corresponding to the size of the primary x-ray beam. Finally, it was confirmed that both analytical methods could be combined well for use with a microchip. In GE-XRF, the background intensity in the XRF spectrum was reduced at grazing-exit angles. In addition, a good relationship between the x-ray fluorescence intensities and the concentrations of standard solutions that were introduced into the microchip was obtained. This indicates that the GE-XRF method is feasible for trace elemental analysis in chemical microchip systems. In micro-XRF, an attempt was made to concentrate and dry the analyte within a small analyzing region. The preliminary results indicated that the micro-XRF method could be applied for the analysis of microchips.

Journal Article↗

Capillary-assembled microchip for universal integration of various chemical functions onto a single microfluidic device.

A novel concept for assembling various chemical functions onto a single microfluidic device is proposed. The concept, called a capillary-assembled microchip, involves embedding chemically functionalized capillaries into a lattice microchannel network fabricated on poly(dimethylsiloxane) (PDMS). The network has the same channel dimensions as the outer dimensions of the capillaries. In this paper, we focus on square capillaries to be embedded into a PDMS microchannel network having a square cross section. The combination of hard glass square capillary and soft square PDMS channel allows successful fabrication of a microfluidic device without any solution leakage, and which can use diffusion-based two-solution mixing. Two different types of chemically modified capillaries, an ion-sensing capillary and a pH-sensing capillary, are prepared by coating a hydrophobic plasticized poly(vinyl chloride) membrane and a hydrophilic poly(ethyleneglycol) membrane containing functional molecules onto the inner surface of capillaries. Then, they are cut into appropriate lengths and arranged on a single microchip to prepare a dual-analyte sensing system. The concept proposed here offers advantages inherent to using a planar microfluidic device and of chemical functionality of immobilized molecules. Therefore, we expect to fabricate various types of chemically functionalized microfluidic devices soon.

Journal Article↗

Micro wet analysis system using multi-phase laminar flows in three-dimensional microchannel network.

A three-dimensional microchannel network with two-level crossings of channels was constructed in a glass microchip by sandwiching an insulating glass plate between two glass plates with microchannels followed by thermal bonding. Pressure-driven stable multi-phase laminar flows inside the three-dimensional channel network were realized by balancing flow rates of syringe pumps. Micro unit operations for mixing, reaction, solvent extraction, and detection were properly arranged in the multi-phase laminar flows, so that four parallel analyses, comprising twenty unit operations in total, could be integrated onto a single chip. Two chelating reagents and two sample solutions containing heavy metal ions (Fe(ii) or Co(ii)) were mixed and reacted in four different combinations using the three-dimensional channel network. After chelating reactions were completed, post processing (solvent extraction or addition of acid) was applied to each solution stream to remove the interferences of coexisting metal ions. Finally, target metal complexes were detected using a thermal lens microscope (TLM). Integrity of the micro system was confirmed by qualitative analysis of Fe(ii) and Co(ii). This is the first example of continuous flow chemical processing utilizing multi-phase laminar flow realized in a three-dimensional channel network.

Glass↗

Chemicofunctional membrane for integrated chemical processes on a microchip.

Here we report a design and synthesis of a chemically functional polymer membrane by an interfacial polycondensation reaction and multilayer flow inside a microchannel. Single and parallel dual-membrane structures are successfully prepared by using organic/aqueous two-layer flow and organic/aqueous/organic three-layer flow inside the microchannel followed by an interfacial polycondensation reaction. By using the inner-channel membrane, permeation of ammonia species through the inner-channel membrane is successfully achieved. Furthermore, horseradish peroxidase is immobilized on one side of the membrane surface to integrate the chemical transform function onto the inner-channel membrane. Here substrate permeation through the membrane and subsequent chemical transformation at the membrane surface are realized. The polymer membrane prepared inside the microchannel has an important role in ensuring stable contact of different phases such as gas/liquid or liquid/ liquid and the permeation of chemical species through the membrane. Furthermore, membrane surface modification chemistry allows chemical transformation of permeated chemical species. These methods are expected to lead to development of complicated and sophisticated chemical systems involving membrane permeation and chemical reactions.

Journal Article↗

Chemical processing on microchips for analysis, synthesis, and bioassay.

This review describes our recent research on miniaturization of chemical systems. We have developed a miniaturization methodology based on pressure-driven multiphase laminar flow and a highly sensitive detection tool, the thermal lens microscope. Some representative applications of the methodology in the fields of analysis, synthesis, and bioassay are described.

Microscopy↗

Glass microchip with three-dimensional microchannel network for 2 x 2 parallel synthesis.

An integrated multireactor system for 2 x 2 parallel organic synthesis has been developed on a single glass microchip. Three-dimensional channel circuits in the chip were fabricated by laminating three glass plate layers. The fabrication method is a straightforward extension of the conventional one, and topological equivalence for any three-dimensional circuits can be constructed easily with it. 2 x 2 phase-transfer amide formation reactions, which constitute a simple model for combinatorial synthesis, were successfully carried out on the microchip, and the integrity of the three-dimensional circuits was confirmed. Combinatorial chemistry with multi-microreactors, in conjunction with a high-throughput screening method based on micro-TAS technologies, is expected to provide an efficient tool for drug discovery.

Journal Article↗

Pile-up glass microreactor.

We made a 'pile-up' microreactor in which ten levels of microchannel circuits were integrated to form a single glass entity. Solutions were distributed to each layer via cylindrical holes with a diameter much larger than that of the microchannel. Fabrication of the pile-up reactor was completed using only conventional photolithography, wet etching and thermal bonding techniques, and no special facilities or instruments were required. An amide formation reaction between amine in aqueous solution and acid chloride in organic solution was carried out using the pile-up reactor. The yield of the amide formation reaction is dependent on the size of the specific surface area between the two solutions, and the small space inside the microchannels is good for acquiring a large specific surface area without any stirring processes. The maximum throughput for the ten-layered pile-up reactor was ten times larger than that of a single-layered one, yet the reaction yield was still high. Productivity of the pile-up reactor for the reaction was as high as on a gram per hour scale. This value suggests that many conventional plants producing fine chemicals can be replaced by microreactors through the numbering-up technology.

Journal Article↗

Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels.

We demonstrated a liquid/liquid and a gas/liquid two-phase crossing flow in glass microchips. A 250-microm-wide microchannel for aqueous-phase flow was fabricated on a top glass plate. Then, as a way to utilize the surface energy difference for stable phase confluence and separation, a 250-microm-wide microchannel for organic-phase (or gas-phase) flow was fabricated on a bottom glass plate and the wall was chemically modified by octadecylsilane (ODS) group. The top and bottom plates were sealed only by pressure. A microchannel pattern was designed so that the two phases made contact at the crossing point of the straight microchannels. The crossing point was observed with an optical microscope. Results showed that the ODS modification of the microchannel wall clearly improved stability of the interface between the two fluids. Pressure difference between fluids was measured and the interface of water and nitrobenzene was stable for the pressure difference from +300 Pa to -200 Pa. The pressure drop in a countercurrent flow configuration was also estimated, and the pressure difference required to realize the counter current flow was less than the allowable pressure range. Finally, we discussed the advantages of utilizing this approach.

Journal Article↗