PubMed Health⌕ Search

Biomedical subjects

Yoshimasa Murakami

Publications and source records attributed to Yoshimasa Murakami.

17 recordsLinked to original sources

A novel catheter for simultaneous angiography of ipsilateral pulmonary veins.

We designed a novel catheter for simultaneous angiography of ipsilateral pulmonary veins (PVs), so that the catheter tip with side holes can be introduced into the inferior PVs and a second curve with side holes into the superior PVs. The simultaneous angiogram of the ipsilateral PVs, using this novel catheter, reveals more clearly the PV ostium to antrum, because simultaneous injection of contrast medium into two adjacent PVs reduces the dilution of contrast medium by blood flow through these veins.

Atrial Fibrillation↗

Plasma atrial natriuretic Peptide and brain natriuretic Peptide levels after radiofrequency catheter ablation of atrial fibrillation.

It has been reported that plasma atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) levels are elevated in patients with atrial fibrillation (AF). The aim of this study was to investigate the change in these patients after pulmonary vein isolation (PVI). In 66 patients with paroxysmal AF (PAF) and without any structural heart disease, plasma ANP and BNP levels were measured before and 3 months after successful PVI. At baseline, in 14 patients, ANP and BNP levels were elevated, and in 52 patients, only BNP levels were elevated. There were no significant relations between the attack frequency or the duration of PAF episodes and ANP or BNP levels. Neither ANP nor BNP level at baseline was a valid predictor of AF recurrence. Even in 31 patients (47%) with recurrent PAF, attacks of PAF were significantly reduced. In 66 patients with elevated ANP and/or BNP levels at baseline, levels were significantly reduced after PVI independent of PAF recurrence (ANP: 69.0+/-23.0 vs 25.0+/-7.7 pg/ml, p<0.0001; BNP: 58.4+/-50.7 vs 22.5+/-27.1 pg/ml, p<0.0001). In 42 patients without AF recurrences, ANP and BNP levels were reduced to within the normal range. In conclusion, in patients with PAF without any structural heart disease, ANP and/or BNP levels were elevated. In those patients, relief of the AF burden by successful PVI significantly reduced elevated plasma ANP and BNP levels.

Atrial Fibrillation↗

Usefulness of esophageal leads for determining the strategy of pulmonary vein ablation to avoid complications associated with the esophagus.

To avoid fatal complications after extensive pulmonary vein (PV) ablation, it has been proved important to comprehend the anatomic relation between the PVs and the esophagus. In 42 consecutive patients with atrial fibrillation, PV ostial isolation was performed using a basket catheter. The shortest distance and anatomic relation between the esophageal lead and PV ostium, determined by successful PV ostial isolation, was analyzed in biplane fluoroscopic views. In 18 left superior PVs (LSPVs) (43%), 13 left inferior PVs (32%) (LIPVs), and all the right PVs (group A), the shortest distance was > 10 mm in > or = 1 of the biplane fluoroscopic views. In 4 LSPVs (10%) and 2 LIPVs (5%) (group B), the shortest distance was < or = 5 mm in the fluoroscopic views. In the remaining PVs (group C), the esophagus was situated directly behind 10 LSPVs (24%) and 12 LIPVs (29%) (group C1), posteromedial to 1 LSPV (2%) and 9 LIPVs (22%) (group C2), and medial to 9 LSPVs (21%) and 5 LIPVs (12%) (group C3). The risk of esophagus-associated complications with ablation around the left PV ostia was suggested to be high in group B, very low in group A, and relatively low in group C. In group C3, extensive PV ablation might increase the risk of that complication. In conclusion, esophageal leads are useful for determining strategies for PV ablation to avoid esophagus-associated complications, because they enable comprehension of the anatomic relation between the PVs and the esophagus.

Atrial Fibrillation↗

Incidence, location, and cause of recovery of electrical connections between the pulmonary veins and the left atrium after pulmonary vein isolation.

AIMS: The aim of this study was to reveal the incidence, location, and cause of recovery of the electrical connections (ECs) between the left atrium and the pulmonary veins (PVs) after the segmental ostial PV isolation (PVI). METHODS AND RESULTS: Pulmonary vein mapping and successful PVI were performed using a computerized three-dimensional mapping system (QMS2trade mark) with a basket catheter in 167 PVs in 53 consecutive patients with atrial fibrillation (AF). In 14 patients with recurrent AF after PVI, the same PV mapping and isolation as in the first procedure were performed, and the PV potential maps constructed by QMS2 in two different procedures were compared. Forty-nine recovered ECs were observed in 27 PVs, and all were eliminated by a few local radiofrequency (RF) applications. Thirty-four (69%) of those ECs recovered at the edge of original ECs, and another 15 (31%) recovered at the mid-portion of the continuous broad original ECs. CONCLUSION: Electrical connection recovery occurred most commonly at the edges of original ECs and occasionally at the mid-portion of continuous broad original ECs after PVI probably due to tissue oedema neighbouring the segmental RF lesions. Further RF lesions at the edge of original ECs and linear ablation to the continuous broad ECs may help reduce AF recurrence.

Atrial Fibrillation↗

Electrophysiological pulmonary vein antrum isolation with a multielectrode basket catheter is feasible and effective for curing paroxysmal atrial fibrillation: efficacy of minimally extensive pulmonary vein isolation.

BACKGROUND: How extensive should an appropriate pulmonary vein (PV) ablation be is a matter of controversy. OBJECTIVE: The study's aim was to investigate the efficacy of minimally extensive PV ablation for isolating the PV antrum (PVA) with the guidance of electrophysiological parameters. METHODS: Fifty-five consecutive symptomatic paroxysmal atrial fibrillation (PAF) patients underwent PV mapping with a multielectrode basket catheter (MBC). A 31-mm MBC was deployed in 3-4 PVs as proximally as possible without dislodgement, and the longitudinal PV mapping enabled us to recognize single sharp potentials formed by the total fusion of the PV and left atrial potentials around the PV ostium or the transverse activation patterns that were observed. Those potentials were defined as PVA potentials. Radiofrequency ablation was performed circumferentially targeting PVA potentials with the end point being their elimination. RESULTS: After circumferential PVA ablation, electrical disconnection was achieved in 77% and residual PVA conduction gaps were observed in 23% of all targeted PVs. Those residual conduction gaps were mainly located at the border between ipsilateral PVs (42%) and between the left PVs and left atrial appendage (33%) and were eliminated by a mean of 3 +/- 2 minutes of local radiofrequency deliveries. During the follow-up period (11 +/- 5 months), 46 (84%) patients were free of symptomatic PAF without any anti-arrhythmic drugs. No PV stenosis or spontaneous left atrial flutter occurred. CONCLUSIONS: Electrophysiological PVA ablation with an MBC is feasible and effective for curing PAF because this minimally extensive PVA isolation technique targets the optimal sites, achieving both high efficacy and safety.

Aged↗

Focal atrial fibrillation associated with multiple breakout sites at the crista terminalis.

A 34-year-old man with permanent atrial fibrillation (AF) underwent electrophysiologic testing. Spontaneous AF was observed even after successful pulmonary vein (PV) isolation of all four PVs. Intracardiac electrograms recorded from a basket catheter deployed around the crista terminalis during triggered atrial premature beats exhibited low-amplitude potentials which were suggested to reflect focal ectopic activity, preceding high-frequency atrial potentials. The firing from those focal activity sites induced a shift in the breakout sites and conduction block to the right atrium, which suggested the participation of preferential conduction. Radiofrequency catheter ablation targeting the focal origin and preferential conduction sites eliminated the AF.

Adult↗

Does RV lead positioning provide additional benefit to cardiac resynchronization therapy in patients with advanced heart failure?

BACKGROUND AND OBJECTIVES: The left ventricular (LV) stimulation site is currently recommended to position the lead at the lateral wall. However, little is known as to whether right ventricular (RV) lead positioning is also important for cardiac resynchronization therapy. This study compared the acute hemodynamic response to biventricular pacing (BiV) at two different RV stimulation sites: RV high septum (RVHS) and RV apex (RVA). METHODS AND RESULTS: Using micro-manometer-tipped catheter, LV pressure was measured during BiV pacing at RV (RVA or RVHS) and LV free wall in 33 patients. Changes in LV dP/dt(max) and dP/dt(min) from baseline were compared between RVA and RVHS. BiV pacing increased dP/dt(max) by 30.3 +/- 1.2% in RVHS and by 33.3 +/- 1.7% in RVA (P = n.s.), and decreased dP/dt(min) by 11.4 +/- 0.7% in RVHS and by 13.0 +/- 1.0% in RVA (P = n.s.). To explore the optimal combination of RV and LV stimulation sites, we assessed separately the role of RV positioning with LV pacing at anterolateral (AL), lateral (LAT), or posterolateral (PL) segment. When the LV was paced at AL or LAT, the increase in dP/dt(max) with RVHS pacing was smaller than that with RVA pacing (AL: 12.2 +/- 2.2% vs 19.3 +/- 2.1%, P < 0.05; LAT: 22.0 +/- 2.7% vs 28.5 +/- 2.2%, P < 0.05). There was no difference in dP/dt(min) between RVHS- and RVA pacing in individual LV segments. CONCLUSIONS: RVHS stimulation has no overall advantage as an alternative stimulation site for RVA during BiV pacing. RVHS was equivalent with RVA in combination with the PL LV site, while RVA was superior to RVHS in combination with AL or LAT LV site.

Cardiac Pacing, Artificial↗

Adenosine can also improve the conduction between the superior vena cava and right atrium after isolation.

A 64-year-old man with atrial tachycardia (AT) 3 years after a superior vena cava (SVC) isolation for atrial fibrillation underwent electrophysiologic testing. SVC mapping with a basket catheter revealed a more frequent activation in the SVC than in either of the atria during the AT and consequently the recovered conduction between the SVC and right atrium. The conduction improved from 3 or 4-1 conduction to 2-1 conduction after adenosine was administered. Ectopic firing in the SVC persisted even after restoration of sinus rhythm by the successful SVC isolation, which was confirmed by adenosine.

Adenosine↗

The distal protection during primary percutaneous coronary intervention alleviates the adverse effects of large thrombus burden on myocardial reperfusion.

BACKGROUND: The presence of intracoronary large thrombus burden (LTB) in the infarct-related artery increases the risk of distal embolization and no-reflow during percutaneous coronary intervention (PCI). Evaluation of whether the distal protection (DP) during primary PCI reduces adverse effects of LTB on myocardial reperfusion and infarct size was investigated. METHODS AND RESULTS: A consecutive series of 88 patients with acute myocardial infarction undergoing primary PCI using DP were compared with 81 consecutive patients treated by primary PCI alone. The DP use showed similar post-procedural myocardial blush grade (MBG)-3 and infarct size, but improved corrected thrombolysis in myocardial infarction frame count (cTFC) (29+/-11 vs 35+/-20, p=0.011) and the incidence of ST-segment resolution (80.7% vs 66.7%, p=0.038). In patients with LTB present, however, the DP use reduced occurrences of no-reflow (0% vs 11.8%, p=0.036) and distal embolization (4.8% vs 17.6%, p=0.129), resulting in higher occurrences of MBG-3 (61.9% vs 35.3%, p=0.021) and ST-segment resolution (78.6% vs 50.0%, p=0.009), lower cTFC values (30+/-8 vs 40+/-22, p=0.012) and smaller infarct size (12.2+/-11.2 vs 18.7+/-11.1, p=0.015). CONCLUSIONS: With an improved myocardial reperfusion and smaller infarct size in patients with LTB, the DP during primary PCI might be a better strategy in this particular setting compared with conventional strategy.

Acute Disease↗

Can segmental pulmonary vein ablation reduce the recurrence of atrial fibrillation when using a higher RF power, larger tip electrode catheter, and additional RF deliveries?: the limitations of point-by-point RF ablation.

The aim of this study was to investigate whether segmental ostial catheter ablation (SOCA) designed to prevent the electrical connections (ECs) between the left atrium and pulmonary veins (PVs) might help increase the efficacy of SOCA in paroxysmal atrial fibrillation (PAF). PV mapping and successful SOCA were performed with a basket catheter in 108 consecutive patients with PAF. Radiofrequency energy was delivered using a maximum output of 30 W with a 4 mm tip catheter (group I; 47) or 40 W with an 8 mm tip catheter (group II; 61). Only in the group II patients were additional radiofrequency deliveries to the specific sites where the ECs tended to recover performed after successful SOCA. After the first procedure, PAF recurred in 47% of the group I patients and 32% of the group II patients. In all 27 patients who underwent repeat procedures, EC recoveries were observed more frequently in group I than in group II (69% versus 49%; P < 0.05). After multiple procedures, there was more freedom from PAF in group II (84%) than in group I (66%) (P < 0.05). SOCA with a higher RF power, larger tip catheter, and additional RF deliveries could achieve a more effective SOCA.

Aged↗

Magenta pigment produced by fungus.

A fungus producing magenta was isolated from cellulosic material by visual observation on Czapek's agar media and the product was conventionally analyzed. The fungal strain that produced magenta pigment was closely related to Phoma herbarum. The type of fibers added to Czapek's medium influenced which pigments were produced. Mycelia attached to the surface of nylon-6 and excreted magenta pigment into the fibers. The pigment structure was partially determined. This is the first report of the production of magenta pigment by a microorganism specifically in the presence of nylon-6 fibers, via an unknown mechanism. This phenomenon raises the question of why and how the fungus disperses the pigment inside the fiber and suggests that fabrics can be dyed using microorganisms.

Ascomycota↗

[Promising efficacy of the sirolimus-eluting stent in patients with acute myocardial infarction].

OBJECTIVES: This study investigated the safety and efficacy of sirolimus-eluting stents (SESs) on early and late outcomes in patients with acute myocardial infarction. METHODS: A series of 100 consecutive patients (September 2004 to November 2005)with acute myocardial infarction undergoing primary stenting using SES ptember 24 hr) was compared with 100 consecutive patients (September 2003 to August 2004) treated with bare metal stent (BMS). The frequency of major adverse cardiac events (MACE) and stent thrombosis, and status of ticlopidine administration were assessed at 270 days. RESULTS: The rates of premature discontinuation of ticlopidine (SES group <3 months: 11%, BMS group <1 month: 11%, p = NS) and stent thrombosis (SES group: 1%, BMS group: 0%, p = NS) were similar in the two groups. At follow-up, restenosis rate and target vessel revascularization rate were lower in the SES group(4% vs 19%, p < 0.001 and 4% vs 10%, p = 0.149, respectively). Furthermore, the occurrence of MACE at 270 days was significantly less frequent in the SES group compared with the BMS group (6% vs. 17%, p = 0.038). Multivariate analysis showed SES use tended to predict 270-day MACE (hazard ratio 0.37, 95% confidence interval 0.14-1.02, p = 0.055). Culprit lesion located in the left main trunk was identified as an independent predictor of 270-day MACE (hazard ratio 5.43, 95% confidence interval 1.07-27.59, p = 0.041). CONCLUSIONS: The use of a SES was not associated with increased risk of stent thrombosis compared with a BMS. With lower rates of restenosis and subsequent target vessel revascularization, SES placement could provide superior outcomes in patients with acute myocardial infarction.

Aged↗

Computerized three-dimensional potential mapping with a multielectrode basket catheter can be useful for pulmonary vein electrical disconnection.

INTRODUCTION: Pulmonary vein (PV) isolation (PVI) has been recently proposed as an effective technique to cure atrial fibrillation (AF). AIMS OF THE STUDY: The aim of this study was to investigate the efficacy of a novel technique utilizing a computerized three-dimensional mapping system (QMS2) with a multielectrode basket catheter (MBC) for PVI and to reveal the relation between the style of breakthrough and the network of the PV musculature. METHODS: Sixty-five consecutive patients with frequent AF attacks underwent PV mapping with a 31-mm MBC, and a three-dimensional color animation of the potential map was constructed by the QMS2. The animation color schema was arranged to minimize the low-amplitude left atrial (LA) potentials and emphasize the high-amplitude PV potentials (PVPs). The longitudinal PVP map enabled us to recognize the true breakthroughs and reveal the network of the PV musculature. RESULTS: A total of 205 PVs (65 left superior PVs, 65 right superior PVs, 57 left inferior PVs and 18 right inferior PVs) were mapped and successful PVI was achieved in all PVs, except one that had no PVPs, with a mean radiofrequency duration of 7 +/- 5 minutes per PV. In about 90% of the PVs, a final radiofrequency application eliminated all the distal PVPs simultaneously because the PVI was performed at the appropriate LA-PV junction. A single segmental breakthrough was detected in 17 PVs, single broad breakthrough in 83 PVs, multiple separate breakthroughs with a distal connection between the PV musculatures extending from each separate breakthrough in 88 PVs and multiple separate breakthroughs without that connection in 16 PVs. During the follow-up period, fifty-one (78%) patients were free of symptomatic AF without any antiarrhythmic drugs after multiple procedures (thirty-three (51%) of those patients after the first procedure) and no PV stenosis was found. CONCLUSIONS: Computerized three-dimensional potential mapping can be useful for PVI because it can not only identify the true breakthrough, but can also confirm the elimination of the breakthroughs by the change in the activation sequence through the network of the PV musculature.

Analysis of Variance↗

Simple and accurate catheter mapping technique to predict atrial fibrillation foci in the pulmonary veins or posterior right atrium.

OBJECTIVES: The purpose of this study was to investigate the efficacy of a novel catheter mapping technique for predicting atrial fibrillation (AF) foci. BACKGROUND: Most AF originates from pulmonary veins (PVs), but some originate from the right atrium. METHODS: We developed an algorithm by correlating the cardiac recordings obtained from multielectrode catheters placed in the posterior right atrium (RA) and esophagus during pacing from the PVs and superior vena cava (SVC) or crista terminalis (CT) in 10 AF patients. We tested the algorithm's accuracy prospectively in 46 AF patients. RESULTS: During pacing from the left PVs, the esophageal potentials preceded all other potentials. During pacing from both the right PVs and SVC-CT, the first component (FP) of the double potential (DP) recorded in the posterior RA preceded all other potentials. The amplitude of the FP was higher than that of the second DP component during pacing from the SVC-CT, whereas the reverse occurred from the right PVs. The activation sequence of the FPs and esophageal potentials was from superior to inferior during pacing from the superior PVs, whereas the reverse occurred from the inferior PVs. The accuracy of predicting 34 foci in the right PVs, 28 foci in left PVs, and 6 foci in SVC-CT was 100% for all, respectively. The accuracy of discriminating foci in the superior PVs from those in the inferior PVs was 97% in the right PVs and 96% in the left PVs. CONCLUSIONS: The technique using mapping catheters placed in the posterior RA and esophagus is feasible and effective for mapping and ablating AF.

Algorithms↗

Electrophysiologic characteristics of atrial tachycardia originating from the right pulmonary veins or posterior right atrium: double potentials obtained from the posterior wall of the right atrium can be useful to predict foci of atrial tachycardia in right pulmonary veins or posterior right atrium.

INTRODUCTION: The right pulmonary veins (RPVs) and posterior wall of the right atrium (PRA) are anatomically located adjacent to each other. The aim of this study was to demonstrate the electrophysiologic characteristics of atrial tachycardia (AT) originating from the PRA or RPVs. METHODS AND RESULTS: A total of 26 consecutive patients with AT originating from the RPVs or PRA underwent detailed atrial endocardial mapping and successful radiofrequency catheter ablation. Eight foci were found in the PRA and 18 foci in the RPVs. Analysis of P wave configuration showed that lead V1 was the most helpful in distinguishing the AT foci between these two sites. In all cases, double potential (DP) configurations were recorded from several electrodes of a multielectrode catheter placed in the PRA, and the first DP component (FP) was the earliest potential recorded from the right atrium during the tachycardia. The amplitude of the FP was higher than that of the second DP component (SP) for AT foci originating in the PRA, whereas the reverse occurred for those in the RPV. The activation sequence of the FP was from superior to inferior for the AT foci in the superior RPV, whereas the reverse occurred for the AT foci in the inferior RPV. CONCLUSION: P wave configuration in lead V1 is helpful in distinguishing AT foci between those originating in the PRA and RPVs. The DPs obtained from the PRA can be useful in predicting whether AT foci originate from the PRA or RPVs.

Adolescent↗

Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

Adult↗