PubMed Health⌕ Search

Biomedical subjects

Yoshitaka Masutani

Publications and source records attributed to Yoshitaka Masutani.

25 records · Page 2Linked to original sources

Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysis.

A fully automated method for computerized detection of pulmonary embolism in spiral computed tomography angiography was developed based on volumetric image analysis. The detection method is based on segmentation of pulmonary vessels to limit the search space, and analysis of several three-dimensional features inside segmented vessel volume. The features utilized are vascular size, local contrast based on mathematical morphology, degree of curvilinearity based on second derivatives, and geometric features such as volume and length. Detection results were obtained for 19 clinical data sets and the performance of the method was evaluated. Using the number and locations of thrombi diagnosed by radiologists as the gold standard, 100% sensitivity was achieved with 7.7 false positives per case, and 85% sensitivity was obtained with 2.6 false positives. For identification of all the positive cases as positive, i.e., detection of at least one thrombus per positive case, 1.9 false positives per case were obtained. These preliminary results suggest that the method has potential for fully automated detection of pulmonary embolism.

Algorithms↗

Computerized detection of colonic polyps at CT colonography on the basis of volumetric features: pilot study.

PURPOSE: To develop a computer-aided diagnosis (CAD) scheme for automated detection of colonic polyps on the basis of volumetric features and to assess its accuracy on the basis of colonoscopy, the standard. MATERIALS AND METHODS: Computed tomographic (CT) colonography was performed in patients with use of standard bowel cleansing, air insufflation, and helical scanning in supine and prone positions. The colon was extracted from volumetric data sets generated from transverse CT sections. Volumetric features characterizing polyps were computed at each point in the extracted colon. Polyps were detected by means of hysteresis thresholding and fuzzy clustering followed by a rule-based test on the basis of feature values. Locations of the detected polyps were compared with those detected at conventional colonoscopy. RESULTS: Forty-one cases were analyzed: nine cases with polyps and 32 without polyps. Each case with polyps had one polyp of clinically important size (six were 5-9 mm; three, 10 mm). Thus, there were 82 volumetric data sets, 18 included polyps. Eighty-nine percent (16 of 18) of the polyps were detected. Each of the two false-negative findings was detected in the other position; thus, 100% of polyp cases were detected, with 2.5 false-positive findings per patient. The false-positive findings were similar to those due to common perceptual errors. Most of the false-positive findings were easily distinguishable from true polyps by experienced radiologists. CONCLUSION: The CAD scheme has the potential to depict polyps with high sensitivity and an acceptable false-positive rate.

Adult↗

[Evaluation of PROPELLER MR imaging: preliminary experiences].

Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) MR imaging (MRI) has a unique ability to correct motion artifacts and is expected to be useful in diffusion-weighted MRI. This article describes preliminary experiences with PROPELLER MRI. PROPELLER uses a radial scan variation of the fast spin-echo sequence and it shows much less spatial deterioration than the echo-planar imaging sequence. To determine the optimal parameters of this technique, we calculated the signal intensities of phantoms and brains in various settings. PROPELLER MR examinations were also performed in 66 patients for clinical use. PROPELLER MRI appears to be a promising and useful technique.

Artifacts↗

Topography of the human corpus callosum using diffusion tensor tractography.

OBJECTIVE: To evaluate the crossing fiber trajectory through the corpus callosum using distortion-corrected diffusion tensor tractography in the human brain. METHODS: After correcting distortion associated with large-diffusion gradients, T2-weighted echo planar images (EPIs) acquired from 10 right-handed healthy men were coregistered into T2-weighted fast spin echo images using linear through sixth-order nonlinear, 3-dimensional, polynomial warping functions. The optimal transformation parameters were also applied to the distortion-corrected diffusion-weighted EPIs. Diffusion tensor tractography through the corpus callosum was reconstructed, employing the "1 or 2 regions of interest" method. RESULTS: Compared with the lines through the genu, those through the rostrum ran more inferiorly and seemed to enter the orbital gyrus. Those lines entering posterior temporal white matter (tapetum) crossed through the ventral portion of the splenium and were clearly distinguished from lines that reached parieto-occipital white matter (forceps major). CONCLUSION: Diffusion tensor tractography is a feasible noninvasive tool to evaluate commissural fiber trajectory.

Adult↗

Corticospinal tracts by diffusion tensor tractography in patients with arteriovenous malformations.

OBJECTIVE: To visualize the corticospinal tract (CST) in patients with arteriovenous malformations (AVMs) by using diffusion tensor tractography (DTT) and to confirm the clinical reliability of DTT in patients with AVMs. METHODS: We performed DTT in 24 patients who had their AVMs near the CST. Tracts and AVMs were shown simultaneously, providing information on their spatial relationships. We also counted numbers of voxels in the DTT-CST at the level of the AVM. RESULTS: DTT was visualized in 23 patients. In all 9 patients with hemiparesis, their DTT-CSTs were involved in the AVM or its surrounding lesion. Their volume of DTT-CST at the affected side was significantly decreased when compared with the contralateral side (P = 0.0469). All 14 patients whose DTT-CSTs were free from lesion had no hemiparesis. CONCLUSIONS: DTT was safe and clinically applicable in patients with AVMs. DTT is recommended when an AVM is located near the corticospinal tract.

Adolescent↗

Periodically rotated overlapping parallel lines with enhanced reconstruction-based diffusion tensor imaging. Comparison with echo planar imaging-based diffusion tensor imaging.

OBJECTIVE: To evaluate diffusion tensor imaging (DTI) based on periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) compared with DTI based on single-shot echo planar imaging (EPI). METHODS: Diffusion tensor data were acquired with PROPELLER (PROPELLER-DTI, 3 NEX), EPI (EPI-DTI2, 16 NEX) with the same acquisition time (11.4 minutes) and with EPI (EPI-DTI1, number of excitations = 4) with a shorter acquisition time (2.8 minutes). Regions of interest were set in the genu and splenium of the corpus callosum, as determined on T2-weighted fast spin echo images and fractional anisotropy (FA) maps, separately. Two neuroradiologists visually evaluated image distortion and quality in the supra- and infratentorial structures. RESULTS: In the genu, standard deviation determined by respective FA maps was decreased in order of PROPELLER-DTI, EPI-DTI1, and EPI-DTI2. Both EPI-DTI sequences were quantitatively superior in the splenium, but PROPELLER-DTI was less distorted. CONCLUSION: Periodically rotated overlapping parallel lines with enhanced reconstruction-DTI could become a complementary tool when qualitatively evaluating seriously distorted structures.

Adult↗

Diffusion tensor tractography of gliomatosis cerebri: fiber tracking through the tumor.

In previous reports, tracts obtained by diffusion tensor (DT) fiber tracking were terminated or deviated by the brain tumors or surrounding edema. There has been no report showing diffusion tensor tractography penetrating through the tumor. A case of glioma is reported, whose DT fiber tract passing through the tumor was observed by changing the threshold of fractional anisotropy.

Aged↗