Fully automated liquid chromatography-mass spectrometry determination of 17beta-estradiol in river water.

Surface modified molecularly imprinted polymers (SM-MIPs) for 17beta-estradiol (E2), utilizing 6-ketoecradiol as a pseudo template were prepared. MIPs for E2 were synthesized using 4-vinyl pyridine and ethylene dimethacrylate as a functional monomer and cross-linking agent, respectively. MIPs selectively retained E2 and provided excellent chromatographic resolution from interfering compounds inherent in river water sample matrices. Therefore, freshly prepared MIPs were applied to quantitative mass spectrometric (negative electrospray ionization mode) detection of low levels of E2 in river water sample. In order to pre-concentrate the target compound for HPLC analysis, column switching was coupled with a pretreatment column packed with the MIPs. The repeatability of actual determinations of river water sample, in which background E2 was not detected, spiked with 50 ng/L of E2 was 2.2% RSD with a detection limit and qualification limit of 1.8 and 5.4 ng/L, respectively. Surface modification of MIP particlefs packed in the pretreatment column provided selective affinity and on-line concentration of low levels of E2 while simultaneously eliminating sample matrix interference, resulting in a significant increase in sensitivity and reproducibility for liquid chromatography-mass spectrometry analysis of E2 in river water sample.

Chromatography, High Pressure Liquid↗

Degeneration of monoaminergic fibers in the aged micrencephalic rat.

Age-related changes in the monoaminergic neuron systems in the brains of methylazoxymethanol acetate (MAM)-induced micrencephalic rats were studied. Neurochemical analysis revealed high levels of serotonin, norepinephrine and associated metabolites in several brain areas of MAM-treated rats. In particular, serotonin levels in the frontal cortex, cingulate cortex and hippocampus of 12-month-old (12 M) MAM-treated rats were significantly higher than in corresponding age-matched controls. Immunohistochemical analysis demonstrated numerous aberrant serotonin-immunoreactive fibers and small numbers of aberrant tyrosine hydroxylase-immunoreactive fibers in the septum, caudate putamen, thalamus, cerebral cortex, hippocampus and midbrain tegmentum of 12 M MAM-treated rats. Aberrant monoaminergic fibers characterized by swollen varicosities and thickening of intervaricose segments were common compared to 12 M control rats. In the cortex and hippocampus of 12 M MAM-treated rats, aberrant fibers were observed near cortical heterotopic tissue. These results indicate early onset of age-related degeneration of monoaminergic fibers in micrencephalic rats. Aged MAM-treated rats may thus offer a good model for studying age-related monoaminergic changes in the cortical heterotopic tissue of human cortical malformations.

Aging↗

Novel surface modified molecularly imprinted polymer focused on the removal of interference in environmental water samples for chromatographic determination.

Uniformly sized molecularly imprinted polymers (MIPs) for bisphenol A (BPA) with surface modification and immobilized intervals of functional monomers afforded by utilizing 4,4'-methylenebisphenol as a pseudo component have been prepared. MIPs for BPA were prepared using 4-vinyl pyridine immobilized in the most effective interval and ethylene glycol dimethacrylate as a functional monomer and cross-linking agent, respectively. Prepared MIPs showed significant selectivity for BPA retention and removal performance for interference in actual samples as the HPLC stationary phase compared to those of ordinary MIPs. These MIPs were employed as pretreatment media of column switching HPLC and the HPLC system provided a detection limit of 0.36 ppt when electrochemical detection was used. Actual samples, including Suwannee River natural organic matter (NOM), were applied and BPA was detected in the NOM even if widely used UV detection was employed.

Chromatography, High Pressure Liquid↗

Silica monolithic membrane as separation medium. Summable property of different membranes for high-performance liquid chromatographic separation.

We studied an applicability of a silica monolithic membrane as separation medium for high-performance liquid chromatography (HPLC). We prepared porous monolithic silica membranes having a three-dimensional network structure to cut and shape into a membrane separation medium. We evaluated chromatographic properties of a variety of solutes using a column containing the membranes with HPLC to elucidate summable property of the membrane separation media. In addition, we made brief study on separation of HbA1c in whole blood with the stacked" membranes having different surface characteristics in one column, which is a membrane column. We confirmed that the membrane column was able to separate HbA1c from other matrix in whole blood to some extent, and it also had an excellent ability for hydrophobic and ion exchange adsorption.

Chromatography, High Pressure Liquid↗

LC/MS determination of bisphenol A in river water using a surface-modified molecularly-imprinted polymer as an on-line pretreatment device.

A new analytical method for the determination of bisphenol A (BPA) by LC/MS was developed and applied to environmental water samples. Quantitative MS detection of BPA was carried out in the negative mode. In order to preconcentrate the target compound yet prevent serious contamination of the water samples from the experimental environment, we employed column switching HPLC coupled with a pretreatment column of surface-modified molecularly-imprinted polymers. The recovery of BPA from a spiked environmental water sample was 102% and the repeatability of actual determinations of water samples containing 20 ng/L of BPA was 5.4% RSD. By modifying the surfaces of the molecularly-imprinted polymer particles packed in the pretreatment column, interference from the water samples was effectively removed, resulting in a significant increase in sensitivity and more reliable results. This method was successfully applied to the trace determination of BPA in environmental water samples using LC/MS.

Benzhydryl Compounds↗

A molecular recognition strategy towards tetra-chlorinated dibenzo-p-dioxins, TCDDs.

Uniformly sized polymeric separation media were prepared using o- or p-xylene as porogenic template to investigate chromatographic selectivity towards tetra-chlorinated dibenzo-p-dioxins (TCDDs). TCDDs having chlorine atoms at ortho positions of phenyl rings were selectively retained on stationary phase prepared with o-xylene as porogenic template, while TCDDs having chlorine atoms at para positions of phenyl ring were found to be retained selectively on the stationary phase imprinted by the porogenic template, p-xylene. Slightly longer cross-linking agent afforded chromatographically selective retention for larger TCDD isomers. It was also found that positional relationship between substituted chlorine atoms was also important for chromatographic recognition.

Chromatography, High Pressure Liquid↗

Chromatographic molecular recognition for catechol-related compounds using thiacalix[4]arene as an effective selector.

Thiacalix[4]arene (5,11,17,23-tetra- tert-butyl-25,26,27,28-tetrahydroxy-2,8,14,20-tetrathiacalix[4]arene) is an amphiphilic molecule comprising four p-tert-butylphenol-like groups ortho-linked by single sulfur atoms. This molecule has a high electron density area owing to the close proximity of the hydroxyl groups and sulfur atoms. We studied the applicability of this interesting compound as a selector for high-performance liquid chromatography (HPLC) thereby presumably exploiting this feature. Firstly, uniformly sized polymer particles were prepared by using a multi-step swelling and polymerization method with ethylene glycol dimethacrylate (EDMA) as a cross-linker. Methacrylic acid (MAA) was introduced onto the surface of the resulting polymer particles through a new modification method. Thiacalix[4]arene was chemically bonded through the MAA group by using 1,4-dibromobutane as a spacer to reduce steric hindrance around the MAA and the polymer particle itself. The performance of the prepared polymer-based thiacalix[4]arene-modified stationary phase was evaluated with HPLC. Specific chromatographic retention behavior was observed for catechol relative to positional isomers of xylene, cresol, and benzene-diol. Catecholamine and catechol showed specific chromatographic retention behavior.

Catecholamines↗

Interval immobilization technique for recognition toward a highly hydrophilic cyanobacterium toxin.

A novel adsorption medium containing selective molecular recognition site for one of the powerful cyanobacterium toxins, Cylindrospermopsin (CYN) was developed using a special technique, namely interval immobilization technique. The adsorption medium was prepared using molecular assembly derived from an alternative-template molecule coupled with functional monomers for fixing the interval between the ionic functional groups in CYN. As results of liquid chromatographic evaluations, selective molecular recognition ability for CYN was observed as expected. Further studies proved that the association constant for CYN on this medium was slightly higher than that on blank polymer.

Adsorption↗

Determination of bisphenol A in environmental water at ultra-low level by high-performance liquid chromatography with an effective on-line pretreatment device.

We have developed a simple HPLC method for the microanalysis of bisphenol A (BPA), which is often contained in environmental water and is known as an endocrine disrupter. HPLC coupled with electrochemical detection requires a simpler procedure of pretreatment compared to GC-MS. In this study, we analyzed BPA using molecularly imprinted polymer as an on-line pretreatment device. This polymer has molecular recognition sites and provides specific selectivity in extraction process. Due to this effect, the detection limit obtained with this HPLC was 0.36 ng/l. This method applied to environmental water and purified water samples containing 2-70 ng/l of BPA successfully. Furthermore, UV detection was performed in some actual analyses.

Benzhydryl Compounds↗

Novel surface-modification techniques for polymer-based separation media. Stimulus-responsive phenomena based on double polymeric selectors.

A pair of polymeric selectors potentially responding to stimulation was introduced onto monosized porous polymer particles to be evaluated as a packing material for HPLC. Possible complexes formed between polyacrylamide (PAAm) and poly(methacrylic acid) (PMAA) were utilized as stimulus responsive polymeric selectors. Uniformly sized base polymer particle was prepared by multi-step swelling and polymerization method, while the introduction of PAAm and PMAA was done by newly invented modification technique. In this technique, a solvent in which both acrylamide (AAm) and methacrylic acid (MAA) monomers are soluble, but PAAm and PMAA are insoluble, was utilized as a modification medium. The polymer particle doubly modified with PAAm and PMAA was utilized as packing material for HPLC and the stimulus responses were evaluated by changing temperature or pH to check change of the slope of a Van't Hoff plot. By using water as a mobile phase, the expected inflection point of the Van't Hoff plot was observed at upper critical solution temperature (UCST) of the polymer complexes and the temperature responsive ability was observed. Moreover, pH responsive ability was studied by using buffer of either pH 4 or 10 as mobile phase. Slope of the plot was changed in buffer of pH 4, but no change of slope was observed in the buffer of pH 10.

Chromatography, High Pressure Liquid↗

Polymer-based adsorption medium prepared using a fragment imprinting technique for homologues of chlorinated bisphenol A produced in the environment.

A polymer-based adsorption medium having molecular recognition ability for homologues of chlorinated bisphenol A produced in environment was prepared using a fragment imprinting technique. 2,6-Dimethyl phenol was utilized as a pseudo-template molecule and the adsorption media prepared was evaluated by high performance liquid chromatography (HPLC) and solid-phase extraction (SPE). As results, the adsorption medium showed preferable chromatographic retention and specific adsorption ability for the chlorinated bisphenol As having chlorine substituents at 3,5-positions through fragment imprinting effect.

Adsorption↗

Recognition of hepatotoxic homologues of Microcystin using a combination of selective adsorption media.

Microcystin, a hepatotoxin produced by cyanobacteria, was chromatographically discriminated with newly prepared selective adsorption media. Since the name Microcystin refers to up to 70 different homologues, we have developed a novel technique to prepare selective recognition sites, based on the "Fragment Imprinting Effect". The homologues of Microcystin can be individually discriminated from each other by antigen-antibody assay as well as by C18-based HPLC. This is mainly due to differences in the three dimensional structure of Microcystin homologues; however, differences in toxicity are relatively small among the homologues. Therefore we have to measure the total amount of Microcystin homologues present to determine contamination by Microcystins. We have demonstrated the first group recognition for Microcystin homologues through combination of two different selective adsorption media prepared by a fragment imprinting technique.

Bacterial Toxins↗

Toxicity recognition of hepatotoxin, homologues of microcystin with artificial trapping devices.

A hepatotoxin produced by cyanobacteria, microcystin (MC), was chromatographically discriminated with newly prepared artificial trapping devices. MC involves up to 70 kinds of homologues, and because homologues have similar toxicity, effective removal and analysis methods have been required. As a trapping device to discriminate MC, we have developed a novel technique for preparation of the "imprinted recognition site" into the crosslinked nano-scale structure, namely "Fragment Imprinting Effect." This technique is simple, and its possible application fields are relatively broad. We have demonstrated the recognition for MC homologues through the combination of two different artificial molecular recognition devices prepared through fragment imprinting technique.

Carcinogens↗

Improved detectability with a polymer-based trapping device in rapid HPLC analysis for ultra-low levels of bisphenol A (BPA) in environmental samples.

A new high-performance liquid chromatography (HPLC) method has been developed to detect ultra-low concentrations of bisphenol-A (BPA) (below 1 ng/L (ppt)) using column switching electrochemical detection (ECD). The results were superior to those obtained from manual pretreatment procedure with membrane stationary phase. BPA is inherently ubiquitous in the environment, including tools and solvents used for its analysis; to obtain meaningful results, therefore, the concentration of the overall BPA contamination must be below the detection limit for BPA using the analytical system. Therefore, purified water for preparing the standard BPA solution must be filtered with a hydrophobic membrane to suppress BPA background levels of contamination. In addition, we investigated methods for effectively preserving environmental water containing BPA. The addition of a small amount of ethylenediaminetetraacetic acid (EDTA) provided good recovery even after overnight storage. By employing these precautionary measures and procedures to reduce BPA contamination from the analytical procedure, we could accurately determine l(-10) ppt of BPA in environmental water samples using a column switching HPLC system.

Benzhydryl Compounds↗

On-column concentration of bisphenol A with one-step removal of humic acids in water.

An efficient extraction method for bisphenol A from environmental water including contaminants was developed using surface selective localization of functional group, on a polymeric separation device. The polymer utilized in this study was prepared through a kind of molecular imprinting technique, namely fragment imprinting effect utilizing a pseudo-template molecule (p-tert.-butylphenol) instead of bisphenol A. The concentration of bisphenol A onto the polymer device prepared, up to 1000 times concentration from environmental water including contaminants (humic acids), was achieved very easily with interesting exclusion effect for humic acids. The results obtained in this study suggest that molecular imprinting with the pseudo-template molecule is quite an effective way for selective concentration of the diluted target molecule from other contaminants including similar functional group with the target molecule.

Benzhydryl Compounds↗