PubMed Health⌕ Search

Biomedical subjects

Youngmee Jung

Publications and source records attributed to Youngmee Jung.

5 recordsLinked to original sources

New technique of seeding chondrocytes into microporous poly(L-lactide-co-epsilon-caprolactone) sponge by cyclic compression force-induced suction.

The initial requirement for a functional engineered cartilage tissue is the effective and reproducible seeding of chondrocytes into the interior of microporous scaffolds. High seeding efficiency, high cell viability, uniform cell distribution, and short operation time are also essential. We devised a new technique of seeding rabbit chondrocytes into microporous poly(L-lactide-co-epsilon-caprolactone) (PLCL) (porosity, 71- 80%; wall thickness, 2 and 6 mm) sponges under compression force-induced suction using a custom designed loading apparatus. Cell distribution and cell viability were determined using confocal laser scanning microscopy with fluorescent dye-staining techniques. Factors that affect the quality of a cell seeded construct were studied, namely, the porosity and thickness of sponges and suction cycles. Under 1 cycle of suction, an increase in porosity promoted cell seeding efficiency (CSE; defined as the percentage of the number of cells in the sponges relative to the initial number of cells seeded), cell viability (at 1 day post seeding), and a relatively uniform cell distribution, whereas thick sponges exhibited an inhomogeneous cell distribution irrespective of incubation time. Multiple cycles of suction of 5 and 10 at 0.1 Hz significantly improved the CSE, whereas high cell viability was maintained and even spatial cell distribution was achieved in 1 week. This study revealed that our newly developed cell seeding technique with multiple cycles of suction is a promising approach to inoculating cells into microporous sponges with high CSE, high cell viability, and homogeneous cell distribution.

Animals↗

Mechano-active scaffold design based on microporous poly(L-lactide-co-epsilon-caprolactone) for articular cartilage tissue engineering: dependence of porosity on compression force-applied mechanical behaviors.

An essential component of functional articular cartilage tissue engineering is a mechano-active scaffold, which responds to applied compression stress and causes little permanent deformation. As the first paper of a series on mechano-active scaffold-based cartilage tissue engineering, this study focused on mechanical responses to various modes of loading of compression forces and subsequent selection of mechano-active scaffolds from the biomechanical viewpoint. Scaffolds made of elastomeric microporous poly(L-lactide-co-epsilon-caprolactone) (PLCL) with open-cell structured pores (300 approximately 500 microm) and with different porosities ranging from 71 to 86% were used. The PLCL sponges and rabbit articular cartilage tissue were subjected to compression/unloading tests (0.1 and 0.005 Hz) at 5 kPa, and stress relaxation tests at 10, 30, and 50% strain. The measurements of the maximum strain under loading and residual strain under unloading for compression tests and the maximum stress and equilibrium stress in the stress relaxation test showed that the lower the porosity, the closer the mechanical properties are to those of native cartilage tissue. Among the PLCL sponges, the sponge with 71% porosity appears to be a suitable cartilage scaffold.

Animals↗

Mechano-active tissue engineering of vascular smooth muscle using pulsatile perfusion bioreactors and elastic PLCL scaffolds.

Blood vessels are subjected in vivo to mechanical forces in a form of radial distention, encompassing cyclic mechanical strain due to the pulsatile nature of blood flow. Vascular smooth muscle (VSM) tissues engineered in vitro with a conventional tissue engineering technique may not be functional, because vascular smooth muscle cells (VSMCs) cultured in vitro typically revert from a contractile phenotype to a synthetic phenotype. In this study, we hypothesized that pulsatile strain and shear stress stimulate VSM tissue development and induce VSMCs to retain the differentiated phenotype in VSM engineering in vitro. To test the hypothesis, rabbit aortic smooth muscle cells (SMCs) were seeded onto rubber-like elastic, three-dimensional PLCL [poly(lactide-co-caprolactone), 50:50] scaffolds and subjected to pulsatile strain and shear stress by culturing them in pulsatile perfusion bioreactors for up to 8 weeks. As control experiments, VSMCs were cultured on PLCL scaffolds statically. The pulsatile strain and shear stress enhanced the VSMCs proliferation and collagen production. In addition, a significant cell alignment in a direction radial to the distending direction was observed in VSM tissues exposed to radial distention, which is similar to that of native VSM tissues in vivo, whereas VSMs in VSM tissues engineered in the static condition randomly aligned. Importantly, the expression of SM alpha-actin, a differentiated phenotype of SMCs, was upregulated by 2.5-fold in VSM tissues engineered under the mechano-active condition, compared to VSM tissues engineered in the static condition. This study demonstrates that tissue engineering of VSM tissues in vitro by using pulsatile perfusion bioreactors and elastic PLCL scaffolds leads to the enhancement of tissue development and the retention of differentiated cell phenotype.

Animals↗

A poly(lactic acid)/calcium metaphosphate composite for bone tissue engineering.

A new method to prepare PLA/CMP (poly-L-lactide/calcium metaphosphate) composite scaffolds was developed for effective bone tissue engineering. This novel sintering method is composed of pressing the mixture of PLA, CMP, and salt particles at 150 MPa for 3 min followed by heat treatment at 210 degrees C for 30 min. The scaffolds had a homogeneously interconnected porous structure without a skin layer, and they exhibited a narrower pore size distribution and higher mechanical strength in comparison with scaffolds made by a solvent casting method. The scaffolds were seeded by osteoblasts and cultured in vitro or implanted into nude mice subcutaneously for up to 5 weeks. The number of cells attached to and proliferated on the scaffolds at both in vitro and in vivo was in the order of; PLA by novel sintering < PLA/CMP by solvent casting < PLA/CMP by novel sintering. In addition, the alkaline phosphatase activity of and calcium deposition in the scaffolds explanted from mice were enhanced significantly for the scaffolds by novel sintering compared to them by solvent casting. The in vitro results agreed well with the in vivo data. Such a superior characteristic of the novel sintering method should have resulted from the fact that the CMP particles could contact directly with cells/tissues to stimulate the cell proliferation and osteogenic differentiation, while the CMP particles would be coated by polymers and hindered to interact with cells/tissues in the case of a solvent casting method. As the novel sintering method does not use any solvents it offers another advantage to avoid problems associated with solvent residue.

Animals↗

Manufacture of elastic biodegradable PLCL scaffolds for mechano-active vascular tissue engineering.

A soft and very elastic poly(lactide-co-epsilon-caprolactone) (PLCL)(50:50, Mn 185 x 10(3)) was synthesized. Tubular scaffolds were prepared by an extrusion-particulate leaching method for mechano-active vascular tissue engineering. The copolymer was very flexible but completely rubber-like elastic. Even the high porous PLCL scaffolds (90% salt wt) exhibited 200% elongation, but recovery over 85% in a tensile test. Moreover, the PLCL scaffolds maintained their high elasticity also in culture media under cyclic mechanical strain conditions. The highly porous scaffold (90% salt wt) withstood for an initial 1 week without any deformation and sustained for 2 weeks in culture media under cyclic stress of 10% amplitude and at 1 Hz frequency which are similar to the natural vascular conditions. Vascular smooth muscle cells (VSMCs) were seeded on to the PLCL scaffolds. The cell adhesion and proliferation on the scaffolds of various pore-size were increased with increasing pore size. For the pore sizes of 50-100 microm, 100-150 microm, 150-200 microm and 200-250 microm, the ratios of cell numbers were about 1:1.2:1.9:2.2, respectively, at both 12 h and 5 days. Similarly, the higher porous scaffolds exhibited more cell adhesion and proliferation compared to lower porous one, where the effect was more pronounced in the longer proliferation period. SMC-seeded scaffolds were implanted subcutaneously in athymic nude mice to confirm the biocompatibility. Such a high elastic property and proper biocompatibility to SMCs of PLCL scaffolds prepared in this study will be very useful to engineer SM-containing tissues such as blood vessels under mechanically dynamic environments (mechano-active tissue engineering).

Animals↗