PubMed Health⌕ Search

Biomedical subjects

Youri Arntz

Publications and source records attributed to Youri Arntz.

7 recordsLinked to original sources

Layer-by-layer self-assembled polyelectrolyte multilayers with embedded liposomes: immobilized submicronic reactors for mineralization.

The development of chemical reactions in nanospaces is of paramount importance for the development of active nanodevices, particularly in nanofluidics. It has been shown in a previous paper that phospholipid vesicles can be incorporated without spontaneous bilayer rupture into poly-L-glutamic acid/poly(allylamine) (PGA/PAH) multilayered polyelectrolyte films. The aim of the present study was to use such a system as an "embedded submicronic reactor" able to trigger precipitation of calcium phosphates within closed spaces through an enzymatic reaction, the enzyme also being encapsulated in the vesicle interior. To this aim, large unilamellar vesicles (LUVs) were produced containing calcium ions as active ions in the mineralization process, spermine as an activator of crystal growth, and alkaline phosphatase as a catalyst to convert phosphate esters into phosphates. After stabilization by adding a layer of poly-(D-lysine), these vesicles were embedded in a (PGA-PAH)n film. A paranitrophenyl phosphate containing solution was then put in contact with this film. It is shown by means of infrared spectroscopy in the attenuated total reflection mode that, consecutively to this contact, calcium phosphates are growing inside the embedded vesicles. By using scanning near-field fluorescence microscopy, it is demonstrated that the alkaline phosphatase enzymes are most probably located inside the vesicles after their embedding. In addition, atomic force microscopy was used to show, after chemical removal of the organic top layer of the film, that the inorganic platelets produced after the precipitation reaction are localized in volumes of similar size and shape as that of the vesicles into which the phosphate ester hydrolysis and subsequent precipitation reaction did occur.

Journal Article↗

Immunogold detection of types I and II chondrocyte collagen fibrils: an in situ atomic force microscopic investigation.

Chondrocyte tissue engineering is a major challenge in the field of cartilage repair. The phenotype of chondrocytes consists of cartilage specific proteoglycan and type II collagen. During serial passages, chondrocytes dedifferentiate into cells, presenting a fibroblast-like phenotype consisting predominately of type I collagen synthesis. Observation of native collagen fibers could be visualized by atomic force microscope. Here, we developed an original and useful atomic force microscopy-based immunogold technique allowing biochemical distinction between types I and II collagen fibers. Imaging of 40-nm gold particles staining collagen fibers was performed in tapping mode. Rat 1 fibroblasts and human chondrosarcoma cells were used as positive models for types I and II collagen, respectively. As demonstrated by our data, primary rat chondrocytes adhering for 48 h on a glass substrate synthesize type II collagen native fibers. This technique allows analyses of local areas of the extracellular matrix of fixed cells, providing complementary data about cartilage phenotype. This simple approach could be of major interest for the biologist community in routine laboratory investigations, to localize in situ, macromolecules of the extracellular matrix.

Animals↗

An extended modeling of the micropipette aspiration experiment for the characterization of the Young's modulus and Poisson's ratio of adherent thin biological samples: numerical and experimental studies.

The micropipette aspiration (MA) experiment remains a quite widely used micromanipulation technique for quantifying the elastic modulus of cells and, less frequently, of other biological samples. However, moduli estimations derived from MA experiments are only valid if the probed sample is non-adherent to the rigid substrate. This study extends this standard formulation by taking into account the influence of the sample adhesion. Using a finite element analysis of the sample aspiration into the micropipette, we derived a new expression of the aspirated length for linear elastic materials. Our results establish that (i) below a critical value, the thickness h of the probed sample must be considered to get an accurate value of its Young's modulus (ii) this critical value depends both on the Poisson's ratio and on the sample adhesivity. Additionally, we propose a novel method which allows the computation of the intrinsic Young's modulus of the adherent probed sample from its measured apparent elasticity modulus. Thanks to the set of computational graphs we derived from our theoretical analysis, we successfully validate this method by experiments performed on polyacrylamide gels. Interestingly, the original procedure we proposed allows a simultaneous quantification of the Young's modulus and of the Poisson's ratio of the adherent gel. Thus, our revisited analysis of MA experiments extends the application domain of this technique, while contributing to decrease the dispersion of elastic modulus values obtained by this method.

Acrylic Resins↗

Application of fluorescence recovery after photobleaching to diffusion of a polyelectrolyte in a multilayer film.

The diffusion coefficient, D, and the proportion of mobile molecules, p, is measured for a fluorescently labeled polyelectrolyte in a multilayer film using fluorescence recovery after photobleaching (FRAP). The film was composed of poly(L-lysine) (PLL) and hyaluronan (HA). The labeled polyelectrolyte (PLL(FITC)) was either deposited on top of the film or embedded within it. A circular area of diameter approximately 60 microm was bleached using a confocal laser scanning microscope. Because molecules do already diffuse during the bleaching step, the initial light intensity profile is not characteristic of a uniformly bleached circular area. A formalism is developed in which a simple mathematical representation of a measured profile serves as starting profile. This radial distribution is introduced in the equation describing the time evolution of the labeled molecule concentration under the hypothesis that the recovery results from pure, two-dimensional Brownian diffusion of the mobile molecules according to Fick's law. The analysis of a series of images taken at successive times after bleaching (up to approximately one hour) leads to estimates of D of the order of 0.2 microm(2) s(-1) for labeled molecules deposited on top of the film and a 5-fold smaller value for the molecules embedded in the film. However, p is remarkably insensitive to the position in the multilayer architecture (p approximately 0.40).

Diffusion↗

Measurement of film thickness up to several hundreds of nanometers using optical waveguide lightmode spectroscopy.

Up to now, most studies based on optical waveguide lightmode spectroscopy (OWLS) were dedicated to thin adlayers, assumed to be isotropic and homogeneous, for which data analysis was based on an approximation of the mode equations valid when the thickness is small with respect to the wavelength of the laser light. The aim of the present paper is to extend the use of OWLS to thicker deposited layers (up to approximately 400 nm). Both the simplified and extended models are compared in terms of optical parameters, i.e. the refractive index nA, the thickness dA, and the optical mass QA, for experimental data obtained with polyelectrolyte multilayer films. The deviation of these parameters can be quite large when derived using the simplified model instead of the extended model. This observation evidences that OWLS is well suited for the study of "thick" films if the appropriate model is applied to the data analysis.

Algorithms↗

Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array.

We report a microarray of cantilevers to detect multiple unlabeled biomolecules simultaneously at nanomolar concentrations within minutes. Ligand-receptor binding interactions such as DNA hybridization or protein recognition occurring on microfabricated silicon cantilevers generate nanomechanical bending, which is detected optically in situ. Differential measurements including reference cantilevers on an array of eight sensors can sequence-specifically detect unlabeled DNA targets in 80-fold excess of nonmatching DNA as a background and discriminate 3' and 5' overhangs. Our experiments suggest that the nanomechanical motion originates from predominantly steric hindrance effects and depends on the concentration of DNA molecules in solution. We show that cantilever arrays can be used to investigate the thermodynamics of biomolecular interactions mechanically, and we have found that the specificity of the reaction on a cantilever is consistent with solution data. Hence cantilever arrays permit multiple binding assays in parallel and can detect femtomoles of DNA on the cantilever at a DNA concentration in solution of 75 nM.

Base Sequence↗