PubMed Health⌕ Search

Biomedical subjects

Yu-Hua Fang

Publications and source records attributed to Yu-Hua Fang.

2 recordsLinked to original sources

System integration and DICOM image creation for PET-MR fusion.

This article demonstrates a gateway system for converting image fusion results to digital imaging and communication in medicine (DICOM) objects. For the purpose of standardization and integration, we have followed the guidelines of the Integrated Healthcare Enterprise technical framework and developed a DICOM gateway. The gateway system combines data from hospital information system, image fusion results, and the information generated itself to constitute new DICOM objects. All the mandatory tags defined in standard DICOM object were generated in the gateway system. The gateway system will generate two series of SOP instances of each PET-MR fusion result; SOP (Service Object Pair) one for the reconstructed magnetic resonance (MR) images and the other for position emission tomography (PET) images. The size, resolution, spatial coordinates, and number of frames are the same in both series of SOP instances. Every new generated MR image exactly fits with one of the reconstructed PET images. Those DICOM images are stored to the picture archiving and communication system (PACS) server by means of standard DICOM protocols. When those images are retrieved and viewed by standard DICOM viewing systems, both images can be viewed at the same anatomy location. This system is useful for precise diagnosis and therapy.

Computer Communication Networks↗

Estimating the input function non-invasively for FDG-PET quantification with multiple linear regression analysis: simulation and verification with in vivo data.

A novel statistical method, namely Regression-Estimated Input Function (REIF), is proposed in this study for the purpose of non-invasive estimation of the input function for fluorine-18 2-fluoro-2-deoxy- d-glucose positron emission tomography (FDG-PET) quantitative analysis. We collected 44 patients who had undergone a blood sampling procedure during their FDG-PET scans. First, we generated tissue time-activity curves of the grey matter and the whole brain with a segmentation technique for every subject. Summations of different intervals of these two curves were used as a feature vector, which also included the net injection dose. Multiple linear regression analysis was then applied to find the correlation between the input function and the feature vector. After a simulation study with in vivo data, the data of 29 patients were applied to calculate the regression coefficients, which were then used to estimate the input functions of the other 15 subjects. Comparing the estimated input functions with the corresponding real input functions, the averaged error percentages of the area under the curve and the cerebral metabolic rate of glucose (CMRGlc) were 12.13+/-8.85 and 16.60+/-9.61, respectively. Regression analysis of the CMRGlc values derived from the real and estimated input functions revealed a high correlation (r=0.91). No significant difference was found between the real CMRGlc and that derived from our regression-estimated input function (Student's t test, P>0.05). The proposed REIF method demonstrated good abilities for input function and CMRGlc estimation, and represents a reliable replacement for the blood sampling procedures in FDG-PET quantification.

Algorithms↗