PubMed Health⌕ Search

Biomedical subjects

Yuan-Qing Xia

Publications and source records attributed to Yuan-Qing Xia.

11 recordsLinked to original sources

Disposition of the dipeptidyl peptidase 4 inhibitor sitagliptin in rats and dogs.

The pharmacokinetics, metabolism, and excretion of sitagliptin [MK-0431; (2R)-4-oxo-4-[3-(trifluoromethyl)-5,6-dihydro[1,2,4]triazolo[4,3-a]pyrazin-7(8H)-yl]-1-(2,4,5-trifluorophenyl)butan-2-amine], a potent dipeptidyl peptidase 4 inhibitor, were evaluated in male Sprague-Dawley rats and beagle dogs. The plasma clearance and volume of distribution of sitagliptin were higher in rats (40-48 ml/min/kg, 7-9 l/kg) than in dogs ( approximately 9 ml/min/kg, approximately 3 l/kg), and its half-life was shorter in rats, approximately 2 h compared with approximately 4 h in dogs. Sitagliptin was absorbed rapidly after oral administration of a solution of the phosphate salt. The absolute oral bioavailability was high, and the pharmacokinetics were fairly dose-proportional. After administration of [(14)C]sitagliptin, parent drug was the major radioactive component in rat and dog plasma, urine, bile, and feces. Sitagliptin was eliminated primarily by renal excretion of parent drug; biliary excretion was an important pathway in rats, whereas metabolism was minimal in both species in vitro and in vivo. Approximately 10 to 16% of the radiolabeled dose was recovered in the rat and dog excreta as phase I and II metabolites, which were formed by N-sulfation, N-carbamoyl glucuronidation, hydroxylation of the triazolopiperazine ring, and oxidative desaturation of the piperazine ring followed by cyclization via the primary amine. The renal clearance of unbound drug in rats, 32 to 39 ml/min/kg, far exceeded the glomerular filtration rate, indicative of active renal elimination of parent drug.

Adenosine Deaminase↗

Metabolism of MK-0524, a prostaglandin D2 receptor 1 antagonist, in microsomes and hepatocytes from preclinical species and humans.

(3R)-4-(4-Chlorobenzyl)-7-fluoro-5-(methylsulfonyl)-1,2,3,4-tetrahydrocyclopenta[b]indol-3-yl acetic acid (MK-0524) is a potent orally active human prostaglandin D(2) receptor 1 antagonist that is currently under development for the prevention of niacin-induced flushing. The major in vitro and in vivo metabolite of MK-0524 is the acyl glucuronic acid conjugate of the parent compound, M2. To compare metabolism of MK-0524 across preclinical species and humans, studies were undertaken to determine the in vitro kinetic parameters (K(m) and V(max)) for the glucuronidation of MK-0524 in Sprague-Dawley rat, beagle dog, cynomolgus monkey, and human liver microsomes, human intestinal microsomes, and in recombinant human UDP glucuronosyltransferases (UGT). A comparison of K(m) values indicated that UGT1A9 has the potential to catalyze the glucuronidation of MK-0524 in the liver, whereas UGT1A3 and UGT2B7 have the potential to catalyze the glucuronidation in the intestine. MK-0524 also was subject to phase I oxidative metabolism; however, the rate was significantly lower than that of glucuronidation. The rate of phase I metabolism was ranked as follows: rat approximately monkey > human intestine > dog > human liver with qualitatively similar metabolite profiles across species. In all the cases, the major metabolites were the monohydroxylated epimers (M1 and M4) and the keto-metabolite, M3. Use of inhibitory monoclonal antibodies and recombinant human cytochromes P450 suggested that CYP3A4 was the major isozyme involved in the oxidative metabolism of MK-0524, with a minor contribution from CYP2C9. The major metabolite in hepatocyte preparations was the acyl glucuronide, M2, with minor amounts of M1, M3, M4, and their corresponding glucuronides. Overall, the in vivo metabolism of MK-0524 is expected to proceed via glucuronidation, with minor contributions from oxidative pathways.

Animals↗

Utility of porous graphitic carbon stationary phase in quantitative liquid chromatography/tandem mass spectrometry bioanalysis: quantitation of diastereomers in plasma.

A major challenge in selecting an appropriate stationary phase for diastereomeric separation is that it is difficult to predict which of the commercially available stationary phases could achieve the required liquid chromatographic (LC) separation. This work describes the selection and evaluation of a porous graphitic carbon (PGC) column coupled with tandem mass spectrometry (MS/MS) for the simultaneous quantitation of an experimental drug candidate (I), its two diastereomeric metabolites (II and III), and its demethylated metabolite (IV) in rat plasma. In addition, we investigated the PGC column for the separation of another drug candidate (VI), its two diastereomeric metabolites (VII and VIII) and its ketone metabolite (IX). The PGC column showed excellent chromatographic resolution for the two diastereomers II and III, as well as for VII and VIII. In contrast, the required resolution for the diastereomers II and III could not be achieved using silica-bonded C(18), C(30), phenyl, perfluorinated, polar embedded and polar end-capped phases. The PGC column showed ruggedness with excellent reproducibility of retention times, peak symmetry and response over a period of more than 400 injections of a plasma acetonitrile-precipitation extract. Excellent accuracy and precision were achieved, with accuracy of 94-108% and intra- and inter-run precision within 9%. This work indicates that PGC is a valuable addition to the repertoire of LC columns used for quantitative LC/MS/MS bioanalysis, especially where the separation and quantitation of diastereomeric analytes is involved.

Animals↗

LC-MS Development strategies for quantitative bioanalysis.

Although quantitative bioanalysis using liquid chromatography in conjunction with atmospheric pressure ionization tandem mass spectrometry (LC-MS/MS) has been in use for approximately fifteen years, new concepts and technologies are continuously being introduced to enhance the multiple steps of quantitative LC-MS/MS bioanalysis. In this review article, we have focused on concepts and technologies that have recently been introduced to achieve further improvements in biological sample collection/storage and extraction, chromatography and mass spectrometric detection. Under these major headings, a number of specific topics are presented, summarizing the most recent findings in these areas. Included among the topics discussed are: off-line plasma extraction, on-line plasma extraction, enhanced mass resolution, atmospheric pressure photoionization, high-field asymmetric waveform ion mobility spectrometry, electron capture atmospheric pressure chemical ionization, enhancing MS detection via formation of anionic and cationic adducts, chemical derivatization, ultra-performance chromatography, hydrophilic interaction chromatography, and MS-friendly ion-pair reversed-phase chromatography. In the end, we discuss potential pitfalls in LC-MS/MS bioanalysis and the means to avoid them. Such pitfalls may occur due to mass spectral interference from metabolites or prodrugs, due to the use of inappropriate calibration standard and quality control samples for analysis involving unstable drugs or metabolites, and due to the wild card phenomenon commonly known as the matrix effect.

Animals↗

Species differences in the elimination of a peroxisome proliferator-activated receptor agonist highlighted by oxidative metabolism of its acyl glucuronide.

A species difference was observed in the excretion pathway of 2-[[5,7-dipropyl-3-(trifluoromethyl)-1,2-benzisoxazol-6-yl]oxy]-2-methylpropanoic acid (MRL-C), an alpha-weighted dual peroxisome proliferator-activated receptor alpha/gamma agonist. After intravenous or oral administration of [14C]MRL-C to rats and dogs, radioactivity was excreted mainly into the bile as the acyl glucuronide metabolite of the parent compound. In contrast, when [14C]MRL-C was administered to monkeys, radioactivity was excreted into both the bile and the urine as the acyl glucuronide metabolite, together with several oxidative metabolites and their ether or acyl glucuronides. Incubations in hepatocytes from rats, dogs, monkeys, and humans showed the formation of the acyl glucuronide of the parent compound as the major metabolite in all species. The acyl glucuronide and several hydroxylated products, some which were glucuronidated at the carboxylic acid moiety, were observed in incubations of MRL-C with NADPH- and uridine 5'-diphosphoglucuronic acid-fortified liver microsomes. However, metabolism was more extensive in the monkey microsomes than in those from the other species. When the acyl glucuronide metabolite of MRL-C was incubated with NADPH-fortified liver microsomes, in the presence of saccharo-1,4-lactone, it underwent extensive oxidative metabolism in the monkey but considerably less in the rat, dog, and human liver microsomes. Collectively, these data suggested that the oxidative metabolism of the acyl glucuronide might have contributed to the observed in vivo species differences in the metabolism and excretion of MRL-C.

Animals↗

Identification of a new source of interference leached from polypropylene tubes in mass-selective analysis.

An interference leached from polypropylene tubes was identified to be a sulfoxide oxidative product of didodecyl 3,3'-thiodipropionate (DDTDP) that is used to prevent oxidative degradation of synthetic polymers. A sulfone oxidative product of DDTDP leached from the polypropylene tubes was also observed. The interfering compounds were isolated by LC and characterized using time-of-flight mass spectrometry and NMR. Authentic sulfoxide and sulfone products of DDTDP were also prepared by reacting DDTDP with hydrogen peroxide reaching an unequivocal structural assignment. In conclusion, when analytes of interest are solubilized in predominantly organic solvents and kept in polypropylene containers, the possibility of contamination from leached chemicals should be taken into account.

Journal Article↗

Trace level quantification of deuterated 17beta-estradiol and estrone in ovariectomized mouse plasma and brain using liquid chromatography/tandem mass spectrometry following dansylation reaction.

A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with dansylation was developed for the simultaneous quantification of exogenously administered deuterated 17beta-estradiol-d4 (E2-d4) and its metabolite, estrone-d4 (E1-d4), in mouse plasma and brain homogenates. The dansylation reaction was simple, fast, and sensitive, and a lower limit of quantification of 50 pg/mL was achieved by using 50 microL of mouse plasma. Interference from endogenous 17beta-estradiol and estrone in plasma and brain samples was minimized by the use of deuterated-E2 as well by utilizing ovariectomized (OVX) mice. The recovery of dansylated derivative exceeded 83% and the reaction was completed within approximately 3 min. The intra- and inter-day assay precision were better than 12.9% and assay accuracy ranged between 92-104% for E1-d4 and E2-d4 in plasma, respectively. The absorption of E2-d4 at both 1 and 3 mg/kg P.O. was rapid, reaching peak plasma concentrations (Cmax) at 5 min post-dose that was the earliest time point obtained, and were 1.1 and 13.8 ng/mL, respectively; the Cmax values for the estrone metabolite, E1-d4, were 1.1 and 43.2 ng/mL, respectively. The area-under-the-plasma-time curve (AUC(0-2 h)) values were determined to be 0.65 and 2.90 ng. h/mL for E2-d4 and 0.77 and 6.74 ng. h/mL for E1-d4, respectively, at 1 and 3 mg/kg. The mean brain-to-plasma ratio for E1-d4 and E2-d4 after P.O. administration of E2-d4 to the OVX mice at 1 and 3 mg/kg indicated that both E1-d4 and E2-d4 were present in the brain as well as in the circulation.

Animals↗

Automated online dual-column extraction coupled with teicoplanin stationary phase for simultaneous determination of (R)- and (S)-propranolol in rat plasma using liquid chromatography-tandem mass spectrometry.

An automated online sample extraction method for rat plasma was developed and validated for the quantification of (R)- and (S)-propranolol following the intravenous administration of either the racemate or the individual enantiomers at 5 mg/kg. A dual-column extraction system coupled to a chiral stationary phase (CSP) was used in conjunction with liquid chromatography-tandem mass spectrometry. In this method, two Oasis HLB extraction columns (50x1.0 mm) in parallel were used for online plasma sample purification and teicoplanin CSP (Chirobiotic T) was used for the enantiomeric separation. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for re-conditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a relatively shorter run time and higher throughput. The lower limit of detection was 0.5 ng/ml and the lower limit of quantification was 2 ng/ml for each enantiomer using 25 microl of rat plasma. The method was validated with a linear calibration curve between 2 and 2000 ng/ml for (R)- and (S)-propranolol, respectively. The intra- and inter-day precision (C.V.) was no more than 7.6% and the accuracy of the assay was between 92 and 103%. The teicoplanin CSP proved to be rugged with excellent reproducibility of chromatographic parameters.

Animals↗

Use of a quadrupole linear ion trap mass spectrometer in metabolite identification and bioanalysis.

A new type of quadrupole linear ion trap mass spectrometer, Q TRAP trade mark LC/MS/MS system (Q TRAP trade mark ), was evaluated for its performance in two studies: firstly, the in vitro metabolism of gemfibrozil in human liver microsomes, and, secondly, the quantification of propranolol in rat plasma. With the built-in information-dependent-acquisition (IDA) software, the instrument utilizes full scan MS in the ion trap mode and/or constant neutral loss scans as survey scans to trigger product ion scan (MS(2)) and MS(3) experiments to obtain structural information of drug metabolites 'on-the-fly'. Using this approach, five metabolites of gemfibrozil were detected in a single injection. This instrument combines some of the unique features of a triple quadrupole mass spectrometer, such as constant neutral loss scan, precursor ion scan and multiple reaction monitoring (MRM), together with the capability of a three-dimensional ion trap. Therefore, it becomes a powerful instrument for metabolite identification. The fast duty cycle in the ion trap mode allows the use of full product ion scan for quantification. For the quantification of propranolol, both MRM mode and full product ion scan in the ion trap mode were employed. Similar sensitivity, reproducibility and linearity values were established using these two approaches. The use of the product ion scan mode for quantification provided a convenient tool in selecting transitions for improving selectivity during the method development stage.

Animals↗

Use of online-dual-column extraction in conjunction with chiral liquid chromatography tandem mass spectrometry for determination of terbutaline enantiomers in human plasma.

An online sample extraction chiral bioanalytical method was developed and validated for the quantification of terbutaline, a beta2-selective adrenoceptor agonist, spiked into human plasma by using two extraction columns and a chiral stationary phase (CSP) in conjunction with liquid chromatography tandem mass spectrometry (LC-MS/MS). In this method, two Oasis HLB extraction columns were used in parallel for plasma sample purification and a Chirobiotic T CSP was used for enantiomeric separation. Atmospheric pressure chemical ionization MS/MS was employed in multiple reaction monitoring mode for the detection and quantification. Subsequent to the addition of an internal standard solution, the plasma samples were directly injected onto the system for extraction and analysis. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for reconditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a shorter run time and higher throughput. A lower limit of quantification of 1.0 ng/mL was achieved using only 50 microliter of human plasma. The method was validated with a dynamic range of 1.0-200 ng/mL. The intra- and interday precision was no more than 11% CV and the assay accuracy was between 94-106%.

Chromatography, Liquid↗