Enhanced resolution for EPR imaging by two-step deblurring.

The broad spectrum of spin probes used for electron paramagnetic resonance imaging (EPRI) result in poor spatial resolution of the reconstructed images. Conventional deconvolution procedures can enhance the resolution to some extent but obtaining high resolution EPR images is still a challenge. In this work, we have implemented and analyzed the performance of a postacquisition deblurring technique to enhance the spatial resolution of the EPR images. The technique consists of two steps; noniterative deconvolution followed by iterative deconvolution of the acquired projections which are then projected back using filtered backprojection (FBP) to reconstruct a high resolution image. Further, we have proposed an analogous technique for iterative reconstruction algorithms such as multiplicative simultaneous iterative reconstruction technique (MSIRT) which can be a method of choice for many applications. The performance of the suggested deblurring approach is evaluated using computer simulations and EPRI experiments. Results suggest that the proposed procedure is superior to the standard FBP and standard iterative reconstruction algorithms in terms of mean-square-error (MSE), spatial resolution, and visual judgment. Although the procedure is described for 2D imaging, it can be readily extended to 3D imaging.

Algorithms↗

Quasi Monte Carlo-based isotropic distribution of gradient directions for improved reconstruction quality of 3D EPR imaging.

In continuous wave (CW) electron paramagnetic resonance imaging (EPRI), high quality of reconstructed image along with fast and reliable data acquisition is highly desirable for many biological applications. An accurate representation of uniform distribution of projection data is necessary to ensure high reconstruction quality. The current techniques for data acquisition suffer from nonuniformities or local anisotropies in the distribution of projection data and present a poor approximation of a true uniform and isotropic distribution. In this work, we have implemented a technique based on Quasi-Monte Carlo method to acquire projections with more uniform and isotropic distribution of data over a 3D acquisition space. The proposed technique exhibits improvements in the reconstruction quality in terms of both mean-square-error and visual judgment. The effectiveness of the suggested technique is demonstrated using computer simulations and 3D EPRI experiments. The technique is robust and exhibits consistent performance for different object configurations and orientations.

Algorithms↗

Application of magnetic field over-modulation for improved EPR linewidth measurements using probes with Lorentzian lineshape.

Magnetic field modulation in CW electron paramagnetic resonance (EPR) is used for signal detection. However, it can also distort signal lineshape. In experiments where the linewidth information is of particular importance, small modulation amplitude is usually used to limit the lineshape distortion. The use of small modulation amplitude, however, results in low signal-to-noise ratio and therefore affects the precision of linewidth measurements. Recently, a new spectral simulation model has been developed enabling accurate fitting of modulation-broadened EPR spectra in liquids. Since the use of large modulation amplitude (over-modulation) can significantly enhance the EPR signal, the precision of linewidth measurements is therefore greatly improved. We investigated the over-modulation technique in EPR oximetry experiments using the oxygen-sensing probe lithium octa-n-butoxy-substitued naphthalocyanine (LiNc-BuO). Modulation amplitudes 2-18 times the intrinsic linewidth of the probe were applied to increase the spectral signal-to-noise ratio. The intrinsic linewidth of the probe at different oxygen concentrations was accurately extracted through curve fitting from the enhanced spectra. Thus, we demonstrated that the over-modulation model is also applicable to particulate oxygen-sensing probes such as LiNc-BuO and that the lineshape broadening induced by oxygen is separable from that induced by over-modulation. Therefore, the over-modulation technique can be used to enhance sensitivity and improve linewidth measurements for EPR oximetry with particulate oxygen-sensing probes with Lorentzian lineshape. It should be particularly useful for in vivo oxygen measurements, in which direct linewidth measurements may not be feasible due to inadequate signal-to-noise ratio.

Computer Simulation↗

Optimization of data acquisition for EPR imaging.

In electron paramagnetic resonance imaging (EPRI), long data acquisition time is one of the major problems limiting successful and useful biological EPRI experiments. Depending on the configuration (spatial distribution of paramagnetic species), information embedded in some objects can be characterized using a smaller number of projections, while others may require significantly larger number of projections to generate similar results. In order to optimize the acquisition process, it is therefore important to acquire a different number of projections for different objects. In this paper, a prediction scheme is demonstrated that can determine the number of projections required to achieve a preset reconstruction quality for a given object. After acquiring first few projections, corresponding partially filled k-space is analyzed. The complexity of data (to interpolate) in k-space is quantified and used to predict the number of required projections. All the projections are acquired using a mean-square difference-based adaptive acquisition technique that is also demonstrated in this work. The purpose of this non-uniform acquisition is to reduce redundancy in the acquired data which in turn decreases the number of projections required for the given object. It is also demonstrated that the performance of non-uniform acquisition is content dependant, and for certain configurations it may not be as effective as uniform acquisition in preserving signal from low intensity regions. The prediction scheme along with the non-uniform acquisition is tested using computer simulations, imaging of experimental phantoms, and in vivo imaging. Results indicate that the proposed method may save up to 50% of acquisition time. The techniques in this manuscript are described for 2D spatial imaging but can be extended to 3D imaging.

Algorithms↗

In vivo proton electron double resonance imaging of the distribution and clearance of nitroxide radicals in mice.

Proton electron double resonance imaging (PEDRI) is an emerging technique that utilizes the Overhauser effect to enable in vivo and in vitro imaging of free radicals in biological systems. Nitroxide spin probes enable measurement of tissue redox state based on their reduction to diamagnetic hydroxylamines. PEDRI instrumentation at 0.02 T was applied to assess the ability to image the in vivo distribution, clearance, and metabolism of nitroxide radicals in living mice. Using phantoms of 2,2,5,5-tetramethyl-3-carboxylpyrrolidine-N-oxyl (PCA) in normal saline the dependence of the enhancement on RF power and spin probe concentration was determined. Enhancements of up to -23 were obtained in phantoms with 2 mM levels. Maximum enhancement of -7 was observed in vivo. Coronal images of nitroxide-infused mice enabled visualization of the kinetics of spin probe uptake and clearance in different organs including the great vessels, heart, lungs, kidneys, and bladder with an in-plane spatial resolution of 0.6 mm. PEDRI of living mice was also performed using 3-carbamoyl-proxyl and 2,2,6,6-tetramethyl-4-oxopiperidine-N-oxyl to compare the different rate of clearance and metabolism among different nitroxide probes. PCA, due to its intravascular compartmentalization, provided the sharpest contrast for the vascular system and highest enhancement values in the PEDRI images among the three nitroxides.

Animals↗

Automated on-the-fly detection and correction procedure for EPR imaging data acquisition.

Fast and reliable data acquisition is a major requirement for successful and useful biological electron paramagnetic resonance imaging (EPRI) experiments. Even a technologically advanced and professionally supervised EPRI system can exhibit instabilities initiated by perturbations such as animal motion, microphonics, and temperature changes. As a result, part of an acquired data set may become corrupted with excessive noise and distortions, which in turn may degrade the quality of the reconstructed image. In this work an automated scheme to monitor the system performance and stability over the course of an experiment is demonstrated. This method ensures that the quality of the acquired data is maintained during the experiment. For this purpose, four parameters including noise content and integration of each acquired projection are quantified and measured against those of the zero-gradient (ZG) projection, which is set as a quality benchmark. Projections with parameter values that differ substantially from the expected values are identified as damaged and consequently are reacquired. Therefore, the proposed technique not only effectively monitors the quality of acquisition, it also saves a substantial amount of acquisition time because it eliminates the necessity of repeating the entire experiment in cases in which only a small fraction of the data are corrupted.

Algorithms↗

Real-time calculation and visualization of spectra in field-cycled dynamic nuclear polarization spectroscopy.

Field-cycled dynamic nuclear polarization (FC-DNP), which is based on the Overhauser effect, provides a new way to perform in vivo measurements of free radicals in biological systems. Since it measures the alterations of the nuclear magnetic resonance (NMR) signal in the presence of paramagnetic molecules, a customized program is usually needed in FC-DNP experiments to extract spectral information from the acquired NMR signals. While this program can be designed to calculate the spectrum after all the NMR signals are collected, the batch-processing mode inevitably causes delay and is not convenient for in vivo applications. In this paper, we report the development of a real-time DNP spectrum calculation and visualization program, called RT_DNP, for FC-DNP experiments. A dynamic data exchange (DDE) client was implemented to enable real-time receipt of the system information and the NMR signals from a commercial NMR console. The received NMR signals and experimental parameters were then used to calculate the DNP spectrum during the data acquisition. The real-time DNP spectrum calculation and visualization program was tested in experiments. A seamless integration of the program into a commercial NMR console has been achieved.

Computer Systems↗

Progressive EPR imaging with adaptive projection acquisition.

Continuous wave electron paramagnetic resonance imaging (EPRI) of living biological systems requires rapid acquisition and visualization of free radical images. In the commonly used multiple-stage back-projection image reconstruction algorithm, the EPR image cannot be reconstructed until a complete set of projections is collected. If the data acquisition is incomplete, the previously acquired incomplete data set is no longer useful. In this work, a 3-dimensional progressive EPRI technique was implemented based on inverse Radon transform in which a 3-dimensional EPR image is acquired and reconstructed gradually from low resolution to high resolution. An adaptive data acquisition strategy is proposed to determine the significance of projections and acquire them in an order from the most significant to the least significant. The image acquisition can be terminated at any time if further collection of projections does not improve the image resolution distinctly, providing flexibility to trade image quality with imaging time. The progressive imaging technique was validated using computer simulations as well as imaging experiments. The adaptive acquisition uses 50-70% less projections as compared to the regular acquisition. In conclusion, adaptive data acquisition with progressive image reconstruction should be very useful for the accelerated acquisition and visualization of free radical distribution.

Algorithms↗

Systematic approach to cutoff frequency selection in continuous-wave electron paramagnetic resonance imaging.

This article describes a systematic method for determining the cutoff frequency of the low-pass window function that is used for deconvolution in two-dimensional continuous-wave electron paramagnetic resonance (EPR) imaging. An evaluation function for the criterion used to select the cutoff frequency is proposed, and is the product of the effective width of the point spread function for a localized point signal and the noise amplitude of a resultant EPR image. The present method was applied to EPR imaging for a phantom, and the result of cutoff frequency selection was compared with that based on a previously reported method for the same projection data set. The evaluation function has a global minimum point that gives the appropriate cutoff frequency. Images with reasonably good resolution and noise suppression can be obtained from projections with an automatically selected cutoff frequency based on the present method.

Algorithms↗

In vivo detection of gastric cancer in rats by electron paramagnetic resonance imaging.

Electron paramagnetic resonance imaging (EPRI) enables noninvasive spatial mapping of free radical metabolism and has recently been shown to provide in vivo physiologic information regarding alterations in the redox state of tumors and neoplastic tissues. With the use of nitroxide spin probes, it has been shown that certain tumors possess a highly reduced state. To determine whether EPRI can be used for early detection and visualization of gastric carcinoma based on its altered redox metabolism, studies were performed in a rat gastric cancer model induced by 1-methyl-3-nitro-1-nitrosoguanidine. Using a specialized 750 MHz resonator and EPRI instrument, a technique was developed for imaging nitroxide radicals in the whole stomach. In vivo three-dimensional EPRI of the stomach of rats with continuous intravenous administration of nitroxide 3-carboxamido-2,2,5,5-tetramethylpyrrolidine-N-oxyl (3-carbamoyl-proxyl) [3-CP] was performed. Whereas electron paramagnetic resonance images from untreated controls provide a uniform visualization of the stomach mucosa and wall, in the treated rats with gastric cancer, holes were present in the image at the locations of tumors. With localized spectroscopy, it was confirmed that the tumor regions were devoid of signal, and this was largely due to the presence of a more reduced state with rapid reduction of nitroxide. Pharmacokinetic studies indicated that 3-CP in tumors was rapidly reduced to an undetectable level, whereas the 3-CP levels in normal stomach tissue persisted. Near-infrared reflectance measurements of indocyanine green dye uptake indicated that there were no significant differences in tumor versus normal mucosal perfusion. From these results, we concluded that gastric cancer tumors could be distinguished from normal tissue based primarily on the marked difference in their rate of radical metabolism. Because alterations in cellular redox state and radical metabolism are of critical importance in tumor biology and treatment, this methodology should provide an important new tool for the study and visualization of gastric carcinoma and may also be of use in other cancer models.

Animals↗

Fast EPR imaging at 300 MHz using spinning magnetic field gradients.

Electron paramagnetic resonance imaging (EPRI) technology has rapidly progressed in the last decade enabling many important applications in the fields of biology and medicine. At frequencies of 300-1200 MHz a range of in vivo applications have been performed. However, the requisite imaging time duration to acquire a given number of projections, limits the use of this technique in many in vivo applications where relatively rapid kinetics occur. Therefore, there has been a great need to develop approaches to accelerate EPRI data acquisition. We report the development of a fast low-frequency EPRI technique using spinning magnetic field gradients (SMFG). Utilizing a 300 MHz CW (continuous wave) EPRI system, SMFG enabled over 10-fold accelerated acquisition of image projections. 2D images with over 200 projections could be acquired in less than 3s and with 20s acquisitions good image quality was obtained on large aqueous free radical samples. This technique should be particularly useful for in vivo studies of free radicals and their metabolism.

Algorithms↗

Deconvolution algorithm based on automatic cutoff frequency selection for EPR imaging.

The large line-width associated with electron paramagnetic resonance imaging (EPRI) requires effective algorithms to deconvolve the true spatial profiles of spins from the measured projection data. The commonly used Fourier transform (FT) deconvolution algorithm is easy to implement but suffers from the division-by-zero problem. As a result, a couple of parameters are used to control the deconvolution performance. However, this is inconvenient and the deconvolution results are subject to the experience of the operators. In the present work we examined FT deconvolution for EPRI, and proposed an automatic algorithm to determine the cutoff frequency by calculating the piecewise variance of the division result of the Fourier amplitude spectra. The deconvolution algorithm and the filtered back-projection image reconstruction algorithm were implemented and validated using 3D phantom and in vivo imaging data. It was clearly observed that the image resolution improved after deconvolution with the proposed algorithm.

Algorithms↗

Proton electron double resonance imaging (PEDRI) of the isolated beating rat heart.

Proton electron double resonance imaging (PEDRI) is a double resonance technique where proton MRI is performed with irradiation of a paramagnetic solute. A low-field PEDRI system was developed at 20.1 mT suitable for imaging free radicals in biological samples. With a new small dual resonator, PEDRI was applied to image nitroxide free radicals in isolated beating rat hearts. Experiments with phantoms showed maximum image enhancement factors (IEF) of 42 or 28 with TEMPONE radical concentrations of 2-3 mM at EPR irradiation powers of 12W or 6W, respectively. In the latter case, image resolution better than 0.5 mm and radical sensitivity of 5 microM was obtained. For isolated heart studies, EPR irradiation power of 6W provided optimal compromise of modest sample heating with good SNR. Only a small increase in temperature of about 1 degrees C was observed, while cardiac function remained within 10% of control values. With infusion of 3 mM TEMPONE an IEF of 15 was observed enabling 2D or 3D images to be obtained in 27 sec or 4.5 min, respectively. These images visualized the change in radical distribution within the heart during infusion and clearance. Thus, PEDRI enables rapid and high-quality imaging of free radical uptake and clearance in perfused hearts and provides a useful technique for studying cardiac radical metabolism.

Animals↗

EPR/NMR co-imaging for anatomic registration of free-radical images.

While electron paramagnetic resonance imaging (EPRI) enables spatial mapping of free radicals in the whole body of small animals, it solely visualizes the free-radical distribution and does not typically provide anatomic visualization of the body. However, anatomic registration is often required for meaningful interpretation of the EPRI-derived free-radical images. An approach is reported for whole-body, EPRI-based, free-radical imaging along with proton MRI in mice. EPRI instrumentation with a 750-MHz narrow band microwave bridge and transverse oriented electric field reentrant resonator, with automatic coupling control and automatic tuning control capability, was used to map the spatial distribution of nitroxide free radicals in phantoms and in living mice, while low-field proton MRI at 16 MHz was used to define the anatomic structure to register the EPR images. Small capillary tubes containing an aqueous radical label were used as markers to enable image superimposition. With this coregistration technique, the EPRI free-radical images were precisely registered, enabling assignment of the location of the observed free-radical distribution within the organs of the mice. This technique enabled differentiation of the distribution and metabolism of nitroxide radicals within the major organs and body sites of living mice.

Animals↗

Proton electron double resonance imaging of the in vivo distribution and clearance of a triaryl methyl radical in mice.

Proton electron double resonance imaging (PEDRI) measures the spatial distribution of paramagnetic species in biological samples using the Overhauser effect. Triaryl methyl (TAM) free radicals have been developed as a spin probe for PEDRI since they have very long T(1e). Therefore, low RF power levels are sufficient to saturate the electron spin system with resultant high NMR enhancement facilitating application of PEDRI in living animals. In this report, PEDRI studies were performed at 0.02 T. The power-dependent image enhancement was studied using phantoms of TAM in saline, then the distribution and pharmacokinetics of TAM in living mice were measured. Following intravenous administration of 0.7 mmol/kg of TAM, enhancements of up to -34 were observed enabling visualization of its distribution within the body. Maximum uptake of TAM in the vascular compartment was seen 1 min postadministration with half-clearance within 5 min. Maximum uptake in the kidneys occurred at 10 min with half-clearance at 26 min and maximum accumulation in the bladder after 50 min. Thus, TAM is initially compartmentalized in the vasculature and this is followed by rapid uptake and excretion by the kidneys. PEDRI enabled rapid imaging of the distribution and clearance of this paramagnetic probe and this information should facilitate the use of TAM as a label for oximetry and other applications. Magn Reson Med 48:530-534, 2002.

Animals↗

Mapping of the B1 field distribution of a surface coil resonator using EPR imaging.

Surface coil resonators have been widely used to perform topical EPR spectroscopy. They are usually positioned adjacent to or implanted within the body. For EPR applications these resonators have a number of important advantages over other resonator designs due to their ease of sample accessibility, mechanical fabrication, implementation of electronic tuning and coupling functions, and low susceptibility to sample motions. However, a disadvantage is their B(1) field inhomogeneity, which limits their usefulness for 3D imaging applications. We show that this problem can be addressed by mapping and correcting the B(1) field distribution. We report the use of EPR imaging (EPRI) to map the B(1) distribution of a surface coil resonator. We show that EPRI provides a fast, accurate, and reliable technique to evaluate the B(1) distribution. 3D EPRI was performed on phantoms, prepared using three different saline concentrations, to obtain the B(1) distribution. The information obtained from the phantoms was used to correct the images of living animals. With the use of this B(1) correction technique, surface coil resonators can be applied to perform 3D mapping of the distribution of free radicals in biological samples and living systems.

Animals↗