PubMed Health⌕ Search

Biomedical subjects

Yue-Hua Dou

Publications and source records attributed to Yue-Hua Dou.

3 recordsLinked to original sources

Electrochemical detector for microchip electrophoresis of poly(dimethylsiloxane) with a three-dimensional adjustor.

This paper presents an electrochemical detector for poly(dimethylsiloxane) (PDMS) microchip CE with a three-dimensional adjustor which makes it possible to accurately align a separate working electrode that can be easily fabricated in laboratory to the uncertain PDMS microchannel outlet. The substantial influence of the electrode-PDMS microchannel distance was investigated. The optimal electrode-outlet distance was found to be 10 microm for the PDMS microchannel with the width of 50 microm due to its relatively slow electroosmotic flow. Adrenaline and catechol were well separated, with a linear response range from 20 microM to 1 mM, and a detection limit of 2 microM for catechol, using carbon disk electrode (diameter of 300 microm). Furthermore, arginine and histidine can be well separated and detected directly in the PDMS microchannel using a Cu disk electrode (diameter of 150 microm).

Dimethylpolysiloxanes↗

Separation of proteins on surface-modified poly(dimethylsiloxane) microfluidic devices.

Separation and detection of proteins have been realized on nonionic surfactant-modified poly(dimethylsiloxane) (PDMS) microfabricated devices with end-column amperometric detection. The hydrophobic PDMS channels are turned into hydrophilic ones after being modified with Brij35 and facilitate the separation of proteins. The coating can remarkably reduce the adsorption of large protein molecules and is stable in the range of pH 6-12. The detection of proteins in such channels needs less rinsing time and thus efficiency is raised. Even large molecules of proteins can also be detected with better reproducibility and enhanced plate numbers. The relative standard deviation (RSD) of the migration time for glucose oxidase (GOD) is 2.2% (n = 19). Separation of GOD and myoglobin has been developed in modified channels. Predominant operational variables, such as the coating conditions, the concentration of surfactant and buffer, are studied in detail.

Dimethylpolysiloxanes↗

A dynamically modified microfluidic poly(dimethylsiloxane) chip with electrochemical detection for biological analysis.

Separation and direct detection of amino acids, glucose and peptide in a 3.1 cm separation channel made of poly(dimethylsiloxane) (PDMS) with end-column amperometric detection at a copper microdisk electrode was developed. This system is the integration of a normal sized working electrode with electrochemical detection on a PDMS microfabricated device. The PDMS channels dynamically modified by 2-morpholinoethanesulfonic acid (MES) show less adsorption and more enhanced efficiency than that of unmodified ones when applied to separations of these biological molecules. The migration time is less than 100 s and the reproducibility of migration time is satisfactory with relative standard deviation (RSD) of 2.8% in 19 successive injections. The limits of detection of arginine (Arg), glucose, and methionine-glycine (Met-Gly) are estimated to be 2.0, 8.5, and 64.0 microM at S/N = 3, approximately 0.5-16.0 fmol, respectively. Variances influencing the separation efficiency and amperometric response, including injection, separation voltage, detection potential, or concentration of buffer and additive, are assessed and optimized.

Alkanesulfonic Acids↗