PubMed Health⌕ Search

Biomedical subjects

Yuguo Weng

Publications and source records attributed to Yuguo Weng.

At least 19 recordsLinked to original sources

Impact of heparin-induced thrombocytopenia on outcome in patients with ventricular assist device support: single-institution experience in 358 consecutive patients.

BACKGROUND: Cardiac surgical patients are at an approximate 1% to 2% risk of experiencing heparin-induced thrombocytopenia (HIT), a severe immune-mediated disease that is associated with thromboembolic events. We assessed the occurrence of this disease and its influence on clinical outcome in patients after implantation of a ventricular assist device (VAD). METHODS: This retrospective analysis assessed data from our adult patient VAD program between the years 2000 and 2005. Patients were divided into three groups: those without confirmed HIT ((non)HIT), those in whom the diagnosis of HIT was made before VAD implantation (HIT(pre)), and those who experienced HIT after VAD implantation (HIT(post)). End points assessed were procedural success, as defined by discharge from hospital or transplantation or recovery of the failing heart, as opposed to death before procedural success was achieved. RESULTS: The data of 358 consecutive patients were analyzed. There were 330 (non)HIT patients (91.6%), 15 HIT(pre) patients (4.5%), and 13 HIT(post) patients (3.9%). Procedural success was observed in 50% of (non)HIT patients, 67% of HIT(pre) patients, and 31% of HIT(post) patients. CONCLUSIONS: Heparin-induced thrombocytopenia is a frequent complication in VAD patients and is associated with detrimental outcome when occurring after implantation. Preoperative diagnosis of HIT and the implementation of alternative anticoagulation procedures appears to be associated with better results. Early detection of HIT antibodies before or shortly after VAD implantation and immediate implementation of an alternative anticoagulation regimen may be a strategy to improve outcome.

Adult↗

Postoperative phrenic nerve palsy: early clinical implications and management.

OBJECTIVE: We examined the clinical impact of diaphragmatic palsy (DP) as a result of phrenic nerve injury following cardiothoracic surgery, specifically its effects on morbidity and mortality, early regeneration capacity of the phrenic nerve, and role of surgical diaphragmatic plication. METHODS: A retrospective case control study was performed in 74 children with DP and 74 matched controls after cardiothoracic surgery within the past 14 years. RESULTS: Following 5,128 surgical procedures in children (aged under 18 years) we found an incidence of DP of 1.4%. There were no differences in mortality between the groups, and the cause of death was not related to DP or plication in any of the patients. However, patients with diaphragm impairment had significantly longer duration of mechanical ventilation (median 3 days vs. 1), ICU stay (7 days vs. 3.5), duration of hospital stay (16 days vs. 12), and for antibiotic treatment (16 days vs. 7). Because of prolonged respiratory problems 40 children (54%) underwent surgical diaphragmatic plication to flatten the diaphragm in its inspiratory position. In children with DP younger age was a strong predictor for plication (median 3.8 months vs. 12.1). CONCLUSIONS: Especially in newborns and young infants with DP the length of mechanical ventilation, ICU stay, and hospital stay are prolonged. Early spontaneous recovery of the phrenic nerve is rare. In cases of respiratory impairment early transthoracic diaphragmatic plication is an effective means of treatment.

Cardiac Surgical Procedures↗

Patients supported for over 4 years with left ventricular assist devices.

Ventricular assist device implantation has become an established therapy in adults and children for bridging to heart transplantation or to aid myocardial recovery. Recently, implantation of left ventricular assist devices as definitive therapy has been recognized as a better option than pharmacological treatment in patients who are not candidates for heart transplantation. This study presents our institution's experience with five patients successfully supported by two different left ventricular assist devices for over 4 years. This unique experience shows that left ventricular assist device support can be extended beyond 4 years with good quality of life and low risk, making it a good alternative for non-transplant candidates.

Adult↗

In vitro fabrication of a tissue engineered human cardiovascular patch for future use in cardiovascular surgery.

BACKGROUND: One approach to tissue engineering has been the development of in vitro conditions for the fabrication of functional cardiovascular structures intended for implantation. In this experiment, we developed a pulsatile flow system that provides biochemical and biomechanical signals in order to regulate autologous, human patch-tissue development in vitro. METHODS: We constructed a biodegradable patch scaffold from porous poly-4-hydroxy-butyrate (P4HB; pore size 80 to 150 microm). The scaffold was seeded with pediatric aortic cells. The cell-seeded patch constructs were placed in a self-developed bioreactor for 7 days to observe potential tissue formation under dynamic cell culture conditions. As a control, cell-seeded scaffolds were not conditioned in the bioreactor system. After maturation in vitro, the analysis of the tissue engineered constructs included biochemical, biomechanical, morphologic, and immunohistochemical examination. RESULTS: Macroscopically, all tissue engineered constructs were covered by cells. After conditioning in the bioreactor, the cells were mostly viable, had grown into the pores, and had formed tissue on the patch construct. Electron microscopy showed confluent smooth surfaces. Additionally, we demonstrated the capacity to generate collagen and elastin under in vitro pulsatile flow conditions in biochemical examination. Biomechanical testing showed mechanical properties of the tissue engineered human patch tissue without any statistical differences in strength or resistance to stretch between the static controls and the conditioned patches. Immunohistochemical examination stained positive for alpha smooth muscle actin, collagen type I, and fibronectin. There was minor tissue formation in the nonconditioned control samples. CONCLUSIONS: Porous P4HB may be used to fabricate a biodegradable patch scaffold. Human vascular cells attached themselves to the polymeric scaffold, and extracellular matrix formation was induced under controlled biomechanical and biodynamic stimuli in a self-developed pulsatile bioreactor system.

Absorbable Implants↗

Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in pediatric patients.

BACKGROUND: Pediatric size pneumatically driven extracorporeal ventricular assist devices (VAD) for infants and small children were introduced into clinical routine in 1992. In the initial period, the results in infants were poor. Since then, several improvements have been introduced with regard to the cannulas, connectors, heparin coating of the blood pump inner surface, anticoagulant treatment and coagulation monitoring, and earlier decision-making in favor of pump implantation before irreversible shock has set in. METHODS: Since 1990 and as of January 1, 2005, 62 Berlin Heart Excor systems have been implanted in patients below 18 years of age at our institution. The patients were divided into two groups according to the period of treatment: period 1, devices implanted between 1990 and 1998 (n = 34), and period 2, devices implanted between 1999 and 2004 (n = 28). We compared our experience during the earlier and later periods. RESULTS: There were no significant differences in the preoperative patient data between the two periods except for time of support (17.9 +/- 27.7 days versus 53.2 +/- 83.9 days, p = 0.001). In period 1, more patients needed a biventricular VAD whereas in period 2, more patients were effectively treated with a left VAD (p = 0.05). In the later period, the chest could be primarily closed in a significantly higher percentage of infants (0% versus 89%, p = 0.012), and more infants could be extubated on the VAD (0% versus 55%, p = 0.16). Discharge from the hospital after either weaning from the system or heart transplantation was achieved for 35% in period 1 and for 68% in period 2 (p = 0.029). Whereas in period 1 there were no survivors in the group of children younger than 1 year old, during period 2, survival in this age group was similar to that of the two groups of older children (p = 0.024). There was a significant improvement in the discharge rate in period 2 in patients with cardiomyopathy (43% versus 76%, p = 0.045) and postcardiotomy heart failure (0% versus 57%, p = 0.01). CONCLUSIONS: Earlier implantation of VADs, heparin coating of the blood pumps, and substantial modifications in cannula design, anticoagulation, and the coagulation monitoring regimen have led to a significant increase in the survival and discharge rate, especially among children under 1 year of age. The pediatric size Berlin Heart Excor VAD is a valuable option as a bridge to heart transplantation or recovery for children suffering from cardiogenic shock.

Adolescent↗

Mechanical cardiac support in the young with the Berlin Heart EXCOR pulsatile ventricular assist device: 15 years' experience.

The pediatric-size pneumatically driven pulsatile extracorporeal ventricular assist device (VAD) Berlin Heart EXCOR (Berlin Heart Mediprodukt GmbH, Berlin, Germany) was introduced into clinical practice by the German Heart Institute Berlin in 1992. Until July 1, 2005, Berlin Heart EXCOR systems have been used for circulatory support in 68 children up to 18 years of age with severe circulatory failure resistant to pharmacologic therapy. These were patients suffering from cardiomyopathy, fulminant myocarditis, end-stage congenital cardiac defects, and acute heart failure following congenital heart surgery. Mean VAD support time was 35 days (range, 0 to 420 days). Forty-two patients (62%) survived to transplantation or after weaning; 37 patients (54%), including eight infants, were discharged home. These results in patients with very advanced disease have improved significantly in recent years because of technical developments and growing experience in the treatment of patients on the device, in postoperative care and optimal timing for VAD implantation. Timely implantation of the Berlin Heart EXCOR in the course of progressive heart failure now appears to be justified because the system has undergone the necessary modifications and the accumulation of clinical knowledge has made its use highly reliable and safe.

Adolescent↗

Long-term results in patients with idiopathic dilated cardiomyopathy after weaning from left ventricular assist devices.

BACKGROUND: Since our first successful left ventricular assist device (LVAD) explantation in a patient with idiopathic dilated cardiomyopathy (IDCM) in 1995, an additional 31 IDCM patients have been weaned in our department. Echocardiographic evaluations during repeated "off-pump" trials were the cornerstone for weaning decisions. After 9 years of experience, we assessed the reliability of our weaning criteria in light of the long-term results. METHODS AND RESULTS: We evaluated all of the IDCM patients who were weaned between March 1995 and March 2004 with regard to preservation of cardiac function without LVAD support and survival after weaning. Additionally, we reviewed our echocardiographic data to assess their predictive value for long-term stability of cardiac function after weaning. The 32 weaned IDCM patients showed a survival rate of 78.3%+/-8.1 at 5 years after LVAD explantation. Heart failure (HF) recurred during the first 3 years after weaning in 31.3%. Only 2 patients died because of HF after weaning; the other patients with HF recurrence were successfully transplanted. Off-pump LV end-diastolic diameter >55 mm and/or LVEF <45% before LVAD removal, as well as history of HF > or =5 years before LVAD implantation, appeared to be major risk factors for early recurrence of HF. Patients without any of these 3 risk factors showed no HF recurrence during the first 3 years after weaning, but at the same time, all of those with at least 2 of these 3 risk factors developed early recurrence of HF. In patients with HF recurrence during the first 3 postweaning years, a significant LVEF decrease already occurred during the first month after weaning, whereas in those with long-term stable cardiac function even at the end of the sixth postweaning month, the LVEF was not different from that before LVAD removal. CONCLUSIONS: For selected patients with IDCM, weaning from LVADs is a clinical option with good results over >9 years and should, therefore, be considered in those with cardiac recovery after LVAD implantation. Off-pump echocardiographic data are reliable for the detection of LV recovery and prediction of long-term cardiac stability after weaning.

Adult↗

Homograft reconstruction of the aortic root for endocarditis with periannular abscess: a 17-year study.

OBJECTIVE: The study was conducted to evaluate the long-term results of homograft reconstruction of the left ventricular outflow tract with a cryopreserved aortic homograft in the presence of aortic root abscess associated with a biofilm bacterial infection. METHODS: Between January 1987 and December 2003, 161 patients with aortic root abscess underwent freehand aortic valve (FAVR, N = 78) and aortic root replacement (ARR, N = 83) with an antibiotic treated cryopreserved aortic homograft. Their mean age was 53.1+/-15.6 years. Endocarditis of the native valve was found in 80 patients and of the prosthetic valve in 81; of the prosthetic valves 49 (60.5%) were mechanical and 32 (39%) bioprosthetic. Aortic ventricular discontinuity was found in 83 patients. The common responsible microorganisms were the biofilm bacteria: Staphylococcus (S. epidermidis: 34, S. aureus: 13) in 47 patients followed by Enterococcus in 23 and Streptococcus in 39. Surgery was urgent in 80 patients and emergent in 81, of whom 44 were in cardiogenic shock. Follow-up totaled 810.8 patient-years (mean: 5.0+/-4.3 years) and was 100% complete. RESULTS: Operative mortality was 9.3% for elective/urgent and 14.3% for emergency surgery. A total of 7.3% patients died after hospital discharge during the 17-year follow-up period. The actuarial patient survival at 17 years was 70.4+/-3.6%. Early and late residual/recurrent infections and paravalvular leaks occurred in 4.3 and 2.5%, respectively. Reoperations were carried out in 30 patients, 11 for residual/recurrent infection and paravalvular leaks. Twenty-one patients with FAVR and 9 with ARR techniques underwent reoperation. Early reoperation rate was 4.3%. The actuarial freedom from residual/recurrent infection and paravalvular leaks was 91.6+/-2.4%. Actuarial freedom from reoperation at 17 years was 75+/-3.7%. It was 82.9+/-5.5% for ARR and 63.5+/-6.7% for AAVR technique. The actuarial freedom from structural valve deterioration (SVD) at 17 years was 98.6+/-0.4.% at a rate of %/patient-year. CONCLUSIONS: Radical debridement of the infected aortic root and homograft ARR offer a low recurrent infection rate and an overall low valve-related morbidity and mortality for up to 17 years. The antibiotic permeable cryopreserved homograft has proven to be resistant to biofilm bacterial infection.

Abscess↗

Aortic root abscess and secondary infective mitral valve disease: results of surgical endocarditis treatment.

OBJECTIVE: Mortality in active infective endocarditis (AIE) is substantial and reinfection can strongly influence outcome. Assessment of factors influencing mortality is important. We studied 108 (33%) patients suffering from root abscess out of a total of 327 AIE patients admitted to the Deutsches Herzzentrum Berlin for surgical treatment between 1996 and 2003. Among them were 53 (25.5% of all patients) who were diagnosed as having secondary infective mitral valve disease (SMVD). Mean age was 53+/-14.2 years; there were 37 men and 16 women. METHODS: Risk factors were assessed on the basis of clinical, hemodynamic, echocardiographic and surgical information. Mean follow-up was 325+/-251 days with complete echocardiographic examination performed in patients with double valve surgery. The differences between groups were analyzed using Student's t-test. Multivariate analysis for the whole group suffering from abscess was performed to identify independent factors influencing mortality. RESULTS: In 19 (35.8%) patients suffering from SMVD mitral valve reconstruction was undertaken and mitral valve replacement was performed in 34 (64.2%) patients. There were 27 patients treated with a Shelhigh prosthesis: 18 with double valve replacement (both Shelhigh) and nine with an aortic Shelhigh prosthesis and concomitant mitral valve reconstruction. Homografts were used in 17 patients, with mitral reconstruction in 10 and a stented mitral prosthesis in seven. In nine cases two stented valve prostheses were used. The calculated mean Doppler gradient for homografts and Shelhigh in aortic position was 12 (+/-5.7) and 15 (+/-4.6), respectively (NS). The following predisposing factors for mortality were assessed: severe damage of aortic annulus (OR 4.65, CI 1.22-17.1, P=0.0159); septic shock (OR 3.44, CI 0.85-13.9, P=0.07) and poor ejection fraction (<40%), and dilated LV. CONCLUSIONS: Excessive mortality reaching 29% was noted in patients suffering from AIE with aortic ring abscess and SMVD requiring double valve surgery. Double valve surgery with semi-stented Dacron-free valve prostheses is associated with a low rate of reinfection and good function of the implants. The most potent independent risk factors for death were septic shock and severe aortic root destruction.

Abscess↗

Pneumatic pulsatile ventricular assist devices in children under 1 year of age.

OBJECTIVE: Although considerable progress has been made on ventricular assist devices (VAD) for adults, pneumatic pulsatile circulatory support in young infants is still limited. There is a need for long-term ventricular assist devices to bridge the failing myocardium of young children until recovery or transplantation. Miniaturized devices and innovative modalities need to be optimized. We report on our experience. METHODS: From 1/1992 to 6/2004, 18 infants (6 male/12 female) under 1 year of age were treated with the Berlin Heart Excor VAD. The infants were divided into two groups, depending on the year of treatment. Group A consists of eight infants resuscitated and supported with a pulsatile pneumatic ventricular assist device between 1992 and 1998 and group B consists of 10 infants treated between 1999 and 6/2004. With the pediatric-sized Berlin Heart we used miniaturized extracorporeal pneumatically driven blood pumps, the lowest stroke volume being 10 ml. RESULTS: In 18 children, age 3-345 (median 147) days, artificial replacement of heart function was applied for long-term support (1-64, median 10 days) as a life-saving measure in our hospital. Nine had LVAD and nine BVAD support. All were in cardiogenic shock with multiorgan failure; three had fulminant myocarditis, four cardiomyopathy, and one chronic stage of congenital heart disease. Five children were weaned from the system, three reached heart transplantation, and 10 died on the VAD. There were no differences between groups A and B regarding age, body weight or diagnosis, but the duration of mechanical support differed: Group A, median 2, range 1-16 days; group B, median 12, range 1-100 days. Since 1999 (group B), the survival rate of our small infants has increased to 70% whereas none of the infants in group A survived to be discharged. CONCLUSIONS: The outcome of VAD support in small infants is no longer inferior to that of adult support, now optimized cannulas, modified anticoagulation and optimized surgical and intensive care management have been established.

Anticoagulants↗

Prediction of cardiac function after weaning from ventricular assist devices.

OBJECTIVE: We analyzed the factors influencing the cardiac function of patients after weaning from ventricular assist devices and established a prognostic index. METHOD: A multivariate analysis was performed using the Cox proportional hazards model of the clinical parameters of 28 patients with end-stage heart failure before implantation of a ventricular assist device and directly before weaning from the device. RESULTS: After weaning from the ventricular assist devices, 14 of the 28 investigated patients showed stable cardiac function, and 12 had recurrent heart failure, but only 1 of them died before transplantation or implantation of another ventricular assist device, and 2 patients died of causes unrelated to heart failure. In addition to left ventricular ejection fraction, the duration of symptomatic heart failure and left ventricular intracavitary dimensions in diastole measured before ventricular assist devices weaning were the major factors influencing cardiac function after weaning. In the group of patients with heart failure duration less than 3 years, only 2 of 13 cases were recurrent, but in the group with heart failure duration more than 3 years, 10 of 15 cases were recurrent. In 10 patients with 40 to 50 mm left ventricular intracavitary dimensions in diastole before weaning, only 1 case was recurrent. In 10 patients with 51 to 55 mm left ventricular intracavitary dimensions in diastole, 3 cases were recurrent. In the group with left ventricular intracavitary dimensions in diastole more than 56 mm, all 8 cases were recurrent. A prognostic index was calculated using the following formula: prognostic index = -10.10 + 0.208 (heart failure duration in years) + 0.173 (pre-explantation left ventricular intracavitary dimensions in diastole in millimeters). In the group with a prognostic index less than 0, only 2 of 16 cases were recurrent, and the rate of stable cardiac function in the 51st month after weaning was 83.6%. In the group with a prognostic index greater than 0, 10 of 12 cases were recurrent, and the rate of stable function in the 57th month was 0.0%. CONCLUSION: In patients with off-pump left ventricular ejection fraction greater than 40%, the duration of symptomatic heart failure and the left ventricular intracavitary dimensions in diastole measured before weaning yield a useful index to predict long-term cardiac function after weaning from ventricular assist devices.

Device Removal↗

Consumption of blood products during mechanical circulatory support in children: comparison between ECMO and a pulsatile ventricular assist device.

OBJECTIVE: Different mechanical circulatory support (MCS) systems are used in children with intractable heart failure. However, the need for anticoagulation leads to hemorrhage with subsequent use of blood products. We compared the coagulation disorders and the need for blood products in children treated either with extracorporeal membrane oxygenation (ECMO) or with the Berlin Heart pulsatile pneumatic ventricular assist device. PATIENTS: We retrospectively reviewed the first 8-day course of 64 children who were on MCS for more than 2 days between 1990 and 2002. Thirty children (median age 7.4 years, weight 25.5 kg) received Berlin Heart support and 34 children (median age 1.8 years, weight 9.2 kg) ECMO. Anticoagulation was accomplished by continuous infusion of heparin. Red blood cell count, platelet count, aPTT, AT III, fibrinogen, and ACT were measured regularly. Depending on blood loss and the coagulation disorder, red blood cells, fresh frozen plasma, platelets, and AT III were substituted. RESULTS: There were no preoperative differences in hematological parameters between the two groups. In the Berlin Heart group platelet transfusion was 4.3 ml x kg x day vs 24.6 ml x kg x day in the ECMO group. Red blood cell substitution was 17.2 vs 60.3 ml.kg.day. Fresh frozen plasma substitution was 8.5 ml x kg x day vs 46.9 ml x kg x day (P<0.001). Even in the congenital heart defect subgroups, when MCS was implanted without recent cardiotomy, the differences were significant. Nevertheless, the mean daily values for hemoglobin, platelets, and fibrinogen were lower in the ECMO group. There was lower overall mortality in the Berlin Heart group. CONCLUSIONS: Compared to ECMO, use of the Berlin Heart in children results in less blood loss and lower consumption of red blood cells, platelets, and fresh frozen plasma.

Adolescent↗

Permanent mechanical circulatory support in patients of advanced age.

OBJECTIVE: This study details our initial results of long-term left ventricular assist device (LVAD) support in patients suffering from catecholamine-dependent end-stage heart failure or cardiogenic shock with age above 65 years or age above 60 and contraindications to cardiac transplantation. METHODS: Between September 2000 and July 2002, 27 patients received implantation of left ventricular assist devices (Micromed DeBakey (n=15), Berlin Heart Excor (n=6), Arrow Lion Heart (n=4) and Novacor N100 (n=2)). The mean age of this group was 66.2+/-4.1 (60-77) years. The patients presented with the following features by the time of LVAD implantation: failure of weaning from inotropic support (78%), either profound cardiogenic shock (37%) or instable hemodynamic status (22%), high-dose inotropic (52%) or intraaortic balloon pump support (11%), dialysis (15%), artificial ventilation (15%), and at least one previous cardiac procedure (44%). RESULTS: The cumulative survival rate for the whole group was 63% at 30 days, 30% at 180 days, and 22% at 2 years. The presence of preoperative cardiogenic shock was associated with a higher perioperative mortality rate. Late complications (n=7) included replacement of two thrombosed DeBakey LVADs and five late deaths secondary to thrombembolism/intracranial hemorrhage (DeBakey LVAD, n=3) or septicemia (n=2). As of May 15, 2003, six patients remain on LVAD support for an average of 653 (339-953) days, three patients now for more than 2 years. Ten patients were discharged home to spend 73% of their life span on out-of-hospital long-term LVAD support. CONCLUSION: This study reports the first single-center experience of permanent LVAD support in patients of advanced age. For this initial experience, many patients with critical circulatory status and previous cardiac operations were included and a high postoperative mortality rate was encountered among them. Older age and associated multimorbidity are the key determinants rendering the conditions of LVAD therapy for this patient cohort to be different from the bridge-to-transplant experience. The LVADs employed in this study showed different capabilities with regard to long-term support. Our experience shows that permanent mechanical circulatory support does have the potential to evolve as a treatment option in selected elderly patients with end-stage heart failure.

Aged↗

First experiences with a novel magnetically suspended axial flow left ventricular assist device.

UNLABELLED: Axial flow pumps have gained increased acceptance since their first clinical use in 1998. The present report summarizes the clinical experience with patients treated for severe cardiogenic shock for the first time with a newly developed axial flow pump with magnetically levitated bearings. MATERIAL AND METHODS: The axial flow pump Incor was implanted in 24 patients between June 2002 and June 2003. All except one patient were men. In 16 patients dilative cardiomyopathy, in seven ischemic and in one restrictive cardiomypathy had been diagnosed. All patients presented with catecholamine-dependent end-stage heart failure, seven of them were on an artificial ventilator and three were dependent on intraaortic balloon pump support. All patients suffered from organ dysfunction resulting from low cardiac output. RESULTS: There were no perioperative deaths. The 30-day mortality rate was 8% (n = 2); 79% ( n = 19) of patients reached a condition to be discharged home. The cumulative time on the device is 6.9 years; the longest individual time up to July 1, 2003 is 12.6 months. There were no structural defects or failures of the system. In one case the controller had to be exchanged because of intermittent malfunction. Cardiac output ranged between 4 and 6 l in all instances and there were no cases of infection of the drive-line or the system. Hemolysis was present initially but was not detectable in the later course. There were three instances of transient ischemic attacks. Two patients developed late cardiac tamponade with re-opening of the chest after 9 and 14 days. In one patient persistent gastrointestinal bleeding required re-hospitalization and transfusion therapy. Two patients were weaned from the device after 6 and 7 months of support, respectively. CONCLUSION: The preliminary clinical experience with Incor is promising. The flow is sufficient for recovery from multiorgan failure and the pump allows long-term hemolysis-free support. The concept of magnetically levitated bearings has proven to be durable and reliable. In the case that the heart may recover through unloading, weaning from the pump is possible.

Adult↗