PubMed Health⌕ Search

Biomedical subjects

Yuko Nanbu

Publications and source records attributed to Yuko Nanbu.

2 recordsLinked to original sources

Evaluation of pulmonary function using breathing chest radiography with a dynamic flat panel detector: primary results in pulmonary diseases.

OBJECTIVES: Dynamic flat panel detectors (FPD) permit acquisition of distortion-free radiographs with a large field of view and high image quality. The present study was performed to evaluate pulmonary function using breathing chest radiography with a dynamic FPD. We report primary results of a clinical study and computer algorithm for quantifying and visualizing relative local pulmonary airflow. MATERIALS AND METHODS: Dynamic chest radiographs of 18 subjects (1 emphysema, 2 asthma, 4 interstitial pneumonia, 1 pulmonary nodule, and 10 normal controls) were obtained during respiration using an FPD system. We measured respiratory changes in distance from the lung apex to the diaphragm (DLD) and pixel values in each lung area. Subsequently, the interframe differences (D-frame) and difference values between maximum inspiratory and expiratory phases (D-max) were calculated. D-max in each lung represents relative vital capacity (VC) and regional D-frames represent pulmonary airflow in each local area. D-frames were superimposed on dynamic chest radiographs in the form of color display (fusion images). The results obtained using our methods were compared with findings on computed tomography (CT) images and pulmonary functional test (PFT), which were examined before inclusion in the study. RESULTS: In normal subjects, the D-frames were distributed symmetrically in both lungs throughout all respiratory phases. However, subjects with pulmonary diseases showed D-frame distribution patterns that differed from the normal pattern. In subjects with air trapping, there were some areas with D-frames near zero indicated as colorless areas on fusion images. These areas also corresponded to the areas showing air trapping on computed tomography images. In asthma, obstructive abnormality was indicated by areas continuously showing D-frame near zero in the upper lung. Patients with interstitial pneumonia commonly showed fusion images with an uneven color distribution accompanied by increased D-frames in the area identified as normal on computed tomography images. Furthermore, measurement of DLD was very effective for evaluating diaphragmatic kinetics. CONCLUSIONS: This is a rapid and simple method for evaluation of respiratory kinetics for pulmonary diseases, which can reveal abnormalities in diaphragmatic kinetics and regional lung ventilation. Furthermore, quantification and visualization of respiratory kinetics is useful as an aid in interpreting dynamic chest radiographs.

Adult↗

[Comparison of reproducibility to measure cough sensitivity between our original and astograph methods].

BACKGROUND: We have established a 15-seconds tidal breathing method using our originally developed apparatus to measure cough sensitivity to capsaicin. Astograph, an apparatus to measure bronchial responsiveness to methacholine, has been widely used in clinical practice in Japan. If Astograph is available for measurement of cough sensitivity, it will contribute to promoting the spread of cough sensitivity test. METHODS: Fifteen-seconds tidal breathing methods using our original apparatus and Astograph were compared in 29 healthy subjects. To assess the agreement of the two methods, increasing concentrations of capsaicin solution were inhaled for 15 seconds until 5 or more cough were elicited and cough threshold, the lowest concentration of capsaicin eliciting 5 or more coughs, was determined by each method on 2 separate days at one week interval. On each day, the cough threshold measurement was repeated twice at one-hour interval to assess the repeatability. RESULTS: Difference and repeatability coefficient were 0.35 and 2.00 in our original method and 0.14 and 1.88 doubling concentration in Astograph method, respectively, indicating good repeatability of both methods. Difference and coefficient of agreement between the two methods was 0.30 and 2.44 doubling concentration, respectively. CONCLUSIONS: Astograph is suitable for measurement of cough sensitivity to capsaicin because of its good repeatability and agreement with our original method already established.

Adult↗