Yung-Sung Cheng

Publications and source records attributed to Yung-Sung Cheng.

4 recordsLinked to original sources

Evaluation of respirator filters for asbestos fibers.

Fiber aerosols are known to have different aerodynamic behaviors than spherical particles and usually carry higher electrostatic charges. We investigated the effects of flow rate and charge status of filter cartridges on the penetration of spherical and fiber aerosols. Four types of test respirator filters were selected: two for passive respirators, one for a powered respirator, and one disposable respirator. Surface charges on respirator filters were determined using a noncontact field electrostatic field meter. Penetration tests were performed for filter cartridges before and after charge neutralization. The surface charge measurements on the respirator filters showed that some filters, including those used in disposable face masks, are charged to enhance the collection efficiency. Only high-efficiency particulate air filters performed consistently for both spherical test aerosols and the three types of asbestos fibers. The surface charge potential of filter cartridges and flow rate did not appear to affect the performance of these filters. In contrast to the high-efficiency filters, the aerosol penetration performance of low-efficiency filters and face masks deteriorated when the charge potential on the filter was removed. Our data also showed that the surface charges decreased in a high-temperature, high-humidity environment and disappeared after 1 week. Deposition of spherical particles and fibers in the charged disposable facemask filter was enhanced. For charged-neutralized, low-efficiency filter cartridges, asbestos fibers may penetrate more than spherical particles with a mean particle size of 0.3 microm diameter.

Asbestos↗

Medical nebulizer performance: effects of cascade impactor temperature.

BACKGROUND: During operation of a jet nebulizer, the temperature of the nebulizer outlet could decrease by more than 10 degrees C, depending on the nebulizer type and operating conditions, such as driving flow rate and fill volume. The droplet size distribution generated from the nebulizer can be measured by a cascade impactor. However, when the cascade impactor is operated at ambient room temperature, the droplets could evaporate because of the temperature difference between the nebulizer outlet and the body of the impactor. METHODS: An 8-stage cascade impactor was used to measure the particle size distribution from 4 different types of jet nebulizer (LC Plus, Side-Stream, VixOne, and Micromist) in 2 temperature conditions: ambient (22 degrees C) and low (10 degrees C). Two different formulations, albuterol (aqueous solution) and budesonide (suspension), were used. RESULTS: There was a significantly larger (p < 0.05) mass median aerodynamic diameter and smaller respirable fraction for each nebulizer with the impactor at low temperature than with the impactor at ambient temperature. The mass median aerodynamic diameter of the nebulizers with the impactor operating at low temperature appeared 15-130% larger than with the impactor operating at ambient temperature, for both formulations. The respirable fraction also changed from 10% when the impactor was operated at low temperature to 65% when the impactor was operated at ambient temperature. CONCLUSION: The results provide important information for the use of a cascade impactor to measure the particle-size distribution of nebulizer aerosols.

Administration, Inhalation↗

Dose estimate of inhaled hafnium tritide using the ICRP 66 lung model.

Metal tritide is widely used for research, purification, compression, and storage of tritium. The current understanding of metal tritide and its radiation dosimetry for internal exposure is limited, and ICRP publications do not provide the tritium dosimetry for hafnium tritide. The current radiation protection guidelines for metal tritide particles (including hafnium tritide) are based on the assumption that their biological behavior is similar to tritiated water, which is completely absorbed by the body. However, the solubility of metal tritide particles depends on the chemical form of the material. The biological half-live of hafnium tritide particles and the dosimetry of an inhalation exposure to those particles could be quite different from tritiated water. This paper describes experiments on the dissolution rate of hafnium tritide particles in a simulated lung fluid. The results showed that less than 1% of the tritium was dissolved in the simulated lung fluid for hafnium tritide particles after 215 d. The short-term and long-term dissolution half times were 46 and 4.28 x 10(5) d, respectively. This indicates that hafnium tritide is an extremely insoluble material. Self-absorption of beta rays in the hafnium tritide particles was estimated by a numerical method. The dose coefficients were calculated as a function of particle size using in vitro solubility data and a calculated self-absorption factor. The dose coefficient decreased with aerodynamic diameters in the range of 0.25 to 10 microm, mainly because the self-absorption factor decreased with increasing particle size. For a particle 1 microm in aerodynamic diameter, the dose coefficient of a hafnium tritide particle was about 10 times higher than that of tritiated water but was about 1.4 times lower than that calculated by ICRP Publication 71 for Type S tritiated particles. The ICRP estimate did not include a self-absorption factor and thus might have overestimated the dose. This finding has significant implications for current health protection guidelines.

Air Pollutants, Radioactive↗