PubMed Health⌕ Search

Biomedical subjects

Yunmin Xu

Publications and source records attributed to Yunmin Xu.

4 recordsLinked to original sources

Mesoporous silica nanoreactors for highly efficient proteolysis.

Protein digestion inside the nanoreactor channels of mesoporous silica (SBA-15) is reported, and evaluated by using peptide-mass mapping. Both proteases and substrates were efficiently captured within these biocompatible nanoreactors. After 10 minutes, the mass spectrum of the protein digests released from the mesoporous-silica-based nanoreactors revealed the presence of eight peptides covering 58% of the protein sequence with an intense signal (signal/noise ratio > 70). In comparison, the conventional overnight in-solution digestion of proteins under otherwise identical conditions generated only three peptides (27% sequence coverage). We propose that this order-of-magnitude increase in the proteolytic reaction rate is mainly attributed to two factors: substrate enrichment within mesoporous silica channels and enzyme immobilization. The surface properties and macrostructure of the mesoporous silica were studied to reveal their significant influence on proteolytic reactions.

Hydrolysis↗

Microfluidic enzymatic-reactors for peptide mapping: strategy, characterization, and performance.

The design and characterization of two kinds of poly(dimethylsiloxane)(PDMS) microfluidic enzymatic-reactors along with their analytical utility coupled to MALDI TOF and ESI MS were reported. Microfluidic devices integrated with microchannel and stainless steel tubing (SST) was fabricated using a PDMS casting technique, and was used for the preparation of the enzymatic-reactor. The chemical modification was performed by introducing carboxyl groups to PDMS surface based on ultraviolet graft polymerization of acrylic acid. The covalent and physical immobilization of trypsin was carried out with the use of the activation reagents 1-ethyl-3-(3-dimethyl aminopropyl)carbodiimide(EDC)/N-hydroxysuccinimide (NHS) and a coupling reagent poly(diallyldimethylammonium chloride)(PDDA), respectively. The properties and success of processes of trypsin immobilization were investigated by measuring contact angle, infrared absorption by attenuated total reflection spectra, AFM imaging and electropherograms. An innovative feature of the microfluidic enzymatic-reactors is the feasibility of performing on-line protein analysis by embedded SST electrode and replaceable tip. The lab-made devices provide an excellent extent of digestion of several model proteins even at the fast flow rate of 3.5 microL min(-1) for the EDC/NHS-made device and 0.8 microL min(-1) for the PDDA-made device, which afford very short residence times of 5 s and 20 s, respectively. In addition, the lab-made devices are less susceptive to memory effect and can be used for at least 50 runs in one week without noticeable loss of activity. Moreover, the degraded PDDA-made device can be regenerated by simple treatment of a HCl solution. These features are the most required for microfluidic devices used for protein analysis.

Dimethylpolysiloxanes↗

NADPH-dependent GMP reductase isoenzyme of human (GMPR2). Expression, purification, and kinetic properties.

GMP reductase (EC 1.6.6.8) is the only known metabolic step by which guanine nucleotides can be converted to the pivotal precursor of both adenine and guanine nucleotides. Human GMP reductase has been previously partially purified from erythrocytes and a chromosome 6-linked cDNA has been identified to correspond for encoding human GMP reductase. Here, we reported a distinct cDNA for human GMP reductase isoenzyme isolated from a human fetal brain library, and the GenBank accession number is AF419346. The deduced protein shows 90% identity with human GMP reductase reported (named GMPR1 compared with GMPR2 of this paper) and 69% with E. coli GMP reductase. Comparison of GMPR2 cDNA sequence with human genome indicates the corresponding gene spans about 6.6kb on chromosome 14, which encodes 348 amino acid residues. Northern hybridization analysis indicates a differential and disproportionate expression of mRNAs for GMPR1 and GMPR2, suggesting the existence of distinct molecular species of GMP reductase in human. The apparent Km of GMPR2 for NADPH and GMP are 26.6 and 17.4 microM, respectively. This is the first report suggesting the existence of two distinct types of human GMP reductase molecular species, which can be used to explain the bimodal saturation curve noted with the purified human erythrocyte GMP reductase.

Amino Acid Sequence↗

Titania and alumina sol-gel-derived microfluidics enzymatic-reactors for peptide mapping: design, characterization, and performance.

The design and characterization of titania-based and alumina-based Poly(dimethylsiloxane) (PDMS) microfluidics enzymatic-reactors along with their analytical features in coupling with MALDI-TOF and ESI-MS were reported. Microfluidics with microchannel and stainless steel tubing (SST) were fabricated using PDMS casting and O(2)-plasma techniques, and were used for the preparation of an enzymatic-reactor. Plasma oxidation for the PDMS microfluidic system enabled the channel wall of the microfluidics to present a layer of silanol (SiOH) groups. These SiOH groups act as anchors onto the microchannel wall linked covalently with the hydroxyl groups of trypsin-encapsulated sol matrix. As a result, the trypsin-encapsulated gel matrix was anchored onto the wall of the microchannel, and the leakage of gel matrix from the microchannel was effectively prevented. A feature of the microfluidic enzymatic-reactors is the feasibility of performing on-line protein analysis by attached SST electrode and replaceable tip. The success of trypsin encapsulation was investigated by AFM imaging, assay of enzymatic activity, CE detection, and MALDI-TOF and ESI-MS analysis. The lab-made devices provide an excellent extent of digestion even at a fast flow rate of 7.0 microL/min, which affords the very short residence time of ca. 2 s. With the present device, the digestion time was significantly shortened compared to conventional tryptic reaction schemes. In addition, the encapsulated trypsin exhibits increased stability even after continuous use. These features are required for high-throughput protein identification.

Aluminum Oxide↗