Metabolism-based identification of a potent thrombin receptor antagonist.

The metabolism of our prototypical thrombin receptor antagonist 1, Ki = 2.7 nM, was studied and three major metabolites (2, 4, and 5) were found. The structures of the metabolites were verified independently by synthesis. Compound 4 was shown to be a potent antagonist of the thrombin receptor with a Ki = 11 nM. Additionally, compound 4 showed a 3-fold improvement in potency with respect to 1 in an agonist-induced ex-vivo platelet aggregation assay in cynomolgus monkeys after oral administration; this activity was sustained with 60% inhibition observed at 24 h post-dose. Compound 4 was highly active in functional assays and showed excellent oral bioavailability in rats and monkeys. Compound 4 showed a superior rat enzyme induction profile relative to compound 1, allowing it to replace compound 1 as a development candidate.

Animals↗

Discovery of (1R,5S)-N-[3-amino-1-(cyclobutylmethyl)-2,3-dioxopropyl]- 3-[2(S)-[[[(1,1-dimethylethyl)amino]carbonyl]amino]-3,3-dimethyl-1-oxobutyl]- 6,6-dimethyl-3-azabicyclo[3.1.0]hexan-2(S)-carboxamide (SCH 503034), a selective, potent, orally bioavailable hepatitis C virus NS3 protease inhibitor: a potential therapeutic agent for the treatment of hepatitis C infection.

Hepatitis C virus (HCV) infection is the major cause of chronic liver disease, leading to cirrhosis and hepatocellular carcinoma, which affects more than 170 million people worldwide. Currently the only therapeutic regimens are subcutaneous interferon-alpha or polyethylene glycol (PEG)-interferon-alpha alone or in combination with oral ribavirin. Although combination therapy is reasonably successful with the majority of genotypes, its efficacy against the predominant genotype (genotype 1) is moderate at best, with only about 40% of the patients showing sustained virological response. Herein, the SAR leading to the discovery of 70 (SCH 503034), a novel, potent, selective, orally bioavailable NS3 protease inhibitor that has been advanced to clinical trials in human beings for the treatment of hepatitis C viral infections is described. X-ray structure of inhibitor 70 complexed with the NS3 protease and biological data are also discussed.

Administration, Oral↗

Mapping pharmaceuticals in tissues using MALDI imaging mass spectrometry.

During drug discovery and development stage, often the question is raised as to whether the drug can reach the site of action which helps researchers better assess the potential value of that compound as a pharmaceutical product and toxicological outcomes. High performance liquid chromatography coupled to a tandem mass spectrometer (HPLC-MS/MS) has totally replaced HPLC methods that use UV or other detectors for most drug analysis applications. However, HPLC-MS/MS approaches are not able to provide the answer to certain questions regarding the distribution of a drug in various organs or tissues from laboratory animal experiments. Whole body radioautography (WBA) normally provides a standard means to answer this question on the time course of the drug candidates. However, the major disadvantage in this radioautographic technique is to allow for visualization of total drug-related materials but to image the distribution of the administrated drugs and their metabolites in all tissues. In addition, the availability of radiolabeled compounds at drug discovery stage is another concern. To overcome these issues, matrix-assisted laser desorption/ionization-mass spectrometric method (MALDI-MS) has been developed to directly determine the distribution of pharmaceuticals in tissue sections which might unravel their disposition or biotransformation pathway for new drug development.

Animals↗

Supercritical fluid chromatography-tandem mass spectrometry for the enantioselective determination of propranolol and pindolol in mouse blood by serial sampling.

Packed-column supercritical fluid chromatography (pSFC) coupled to an atmospheric pressure chemical ionization (APCI) source and a tandem mass spectrometer (MS/MS) with minimum sample pretreatment was explored for the rapid and enantioselective determination of (R,S)-propranolol in mouse blood. Serial bleeding of mice is advantageous for the reduction of animal usage, dosing errors, and animal-to-animal variation. The effects of the eluent flow rate and composition as well as the nebulizer temperatures on the ionization efficiency of racemic propranolol and pindolol as model compounds in the positive ion mode under pSFC conditions were studied. The fundamental parameters on the proposed hyphenated system such as matrix ionization suppression and chromatographic performances were investigated in improving sensitivity and enantiomeric separation for the detection of the analytes. The proposed chiral pSFC-APCI/MS/MS approach requiring approximately 3 min/sample for the determination of (R,S)-propranolol at a low nanogram per milliliter region was partially validated with respect to specificity, linearity, reproducibility, and accuracy and was applied to support a pharmacokinetic study.

Adrenergic beta-Antagonists↗

Investigation of the profiling depth in matrix-assisted laser desorption/ionization imaging mass spectrometry.

Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry is generally considered to be a surface analysis technique. In this report, the profiling depth of imaging mass spectrometry was examined. MALDI matrix solution was found to be able to gain access to the tissue interior and extract analyte molecules to the tissue surface. As a consequence, prazosin, a small molecule pharmaceutical compound, located as deep as 40 microm away from the surface was readily detected after matrix application. Likewise, cytochrome c, a 12 kDa protein, was also detectable from the tissue interior. Moreover, for prazosin, not only the extent of matrix effect, but also the extraction efficiency of the matrix solvent appeared to be dependent on the type of tissue. These results indicated that experimental conditions that decrease the matrix solvent evaporation during matrix application may increase analyte extraction efficiency and hence sensitivity of the analysis. Furthermore, thin sections should be used to avoid differential extraction efficiency of matrix solvent in different tissues for whole-body analysis.

Animals↗

Matrix-assisted laser desorption/ionization imaging mass spectrometry for direct measurement of clozapine in rat brain tissue.

Matrix-assisted laser desorption/ionization hyphenated with quadrupole time-of-flight (QTOF) mass spectrometry (MS) has been used to directly determine the distribution of pharmaceuticals in rat brain tissue slices which might unravel their disposition for new drug development. Clozapine, an antipsychotic drug, and norclozapine were used as model compounds to investigate fundamental parameters such as matrix and solvent effects and irradiance dependence on MALDI intensity but also to address the issues with direct tissue imaging MS technique such as (1) uniform coating by the matrix, (2) linearity of MALDI signals, and (3) redistribution of surface analytes. The tissue sections were coated with various matrices on MALDI plates by airspray deposition prior to MS detection. MALDI signals of analytes were detected by monitoring the dissociation of the individual protonated molecules to their predominant MS/MS product ions. The matrices were chosen for tissue applications based on their ability to form a homogeneous coating of dense crystals and to yield greater sensitivity. Images revealing the spatial localization in tissue sections using MALDI-QTOF following a direct infusion of (3)H-clozapine into rat brain were found to be in good correlation with those using a radioautographic approach. The density of clozapine and its major metabolites from whole brain homogenates was further confirmed using fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) procedures.

Animals↗

Ultra-performance liquid chromatography/tandem mass spectrometric determination of testosterone and its metabolites in in vitro samples.

This paper describes the development and partial validation of a fast, sensitive and specific ultra-performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method for the determination of testosterone (T) and its four metabolites, 6beta-OH-T, 16alpha-OH-T, 16beta-OH-T and 2alpha-OH-T, in in vitro samples. The analytical method involves direct dilution of samples with acetonitrile containing an internal standard, followed by separation of testosterone and the four metabolites on an Acquity UPLCtrade mark C(18) column and detected by selected reaction monitoring (SRM) in positive ionization mode using turbo ionspray ionization. The parent compound and its metabolites investigated were well separated (Rs >1.5) with a run time of 4 min under a gradient condition. The method was partially validated. The linear concentration range was 0.01 to 5 microM for all the compounds of interest. Inter-assay mean bias and relative standard deviation (RSD) were in the range of -12% to 8% and 4.1% to 8.5%, respectively. Intra-assay mean bias and RSD were in the range of -8.0% to 5.2% and 3.4% to 9.6%, respectively. The lower limit of quantitation for this assay was 0.01 microM. The differences in LC/MS performance were investigated by conducting a comparison of UPLC with another method previously optimized for HPLC-based separation and quantification of testosterone and its metabolites.

Cells, Cultured↗

Fast mass spectrometry-based methodologies for pharmaceutical analyses.

Historically, most bioanalytical methods for drug analysis in pharmaceutical industry were developed using HPLC coupled with UV or fluorescence detection. However, there is a trend toward interfacing separation technologies with more sensitive tandem mass spectrometry (MS/MS)-based systems. MS/MS detection offers complete resolution of the parent compounds from their first pass metabolites to avoid extra efforts for separation and sample clean-up procedures resulting in shorter run times. With the increasing demand for ever faster screening, there is a continuing demand for bioanalytical methods possessing higher sample throughput for both in vitro and in vivo drug metabolism and pharmacokinetic evaluations to accelerate the discovery process. This review focuses on the current approaches for fast MS-based assays (cycle-time less than 5 min) of pharmaceuticals and their metabolites that have been reported in the peer-reviewed publications.

Mass Spectrometry↗

Increasing speed and throughput when using HPLC-MS/MS systems for drug metabolism and pharmacokinetic screening.

Both combinatorial chemistry and parallel synthesis provide a valuable means for the production of large numbers of compounds with diverse molecular architectures that become available for various drug discovery experiments. In both the lead optimization and lead selection stages, one requirement that is common for many processes is the need for bioanalytical support. This review summarizes current high throughput strategies and efficient methodologies that are employed for drug metabolism and pharmacokinetic (DMPK) screens for a series of drug discovery compounds. For these types of assays, high performance liquid chromatography coupled to a tandem mass spectrometer (HPLC-MS/MS) has now become the technique of choice. The major high throughput strategies including sample reduction and cassette dosing are discussed. The methods for increasing the speed of HPLC-MS/MS-based analyses, such as fast chromatography, direct sample injection, parallel technologies and combined ionization interfaces are also presented in this review. In addition, the special challenges when performing HPLC-MS/MS bioanalysis, such as the choice of ionization sources, matrix ionization suppression and the potential for endogenous interferences, are addressed.

Animals↗

Development of a high-throughput in vitro assay using a novel Caco-2/rat hepatocyte system for the prediction of oral plasma area under the concentration versus time curve (AUC) in rats.

INTRODUCTION: Previously, we have shown that a novel Caco-2/human hepatocyte system is a useful model for the prediction of oral bioavailability in humans. In this study, we attempted to use a similar system in a high-throughput screening mode for the selection of new compound entities (NCE) in drug discovery. METHODS: A total of 72 compounds randomly selected from three different chemotypes were dosed orally in rats. In vivo plasma area under the concentration versus time curve (AUC) from 0-6 h of the parent compound was determined. The same compounds were also tested in the Caco-2/rat hepatocyte system. In vitro AUC from 0-3 h in the Caco-2 rat hepatocyte system was determined. RESULTS: The predictive usefulness of the Caco-2/rat hepatocyte system was evaluated by comparing the in vivo plasma AUC and the in vitro AUC. Linear regression analysis showed a reasonable correlation (R2 = 0.5) between the in vivo AUC and the in vitro AUC. Using 0.4 microM h in vivo AUC as a cut-off, compounds were categorized as either low or high AUC. The in vitro AUC successfully matched the corresponding in vivo category for sixty-three out of seventy-two compounds. DISCUSSION: The results presented in this study suggest that the Caco-2/rat hepatocyte system may be used as a high-throughput screen in drug discovery for pharmacokinetic behaviors of compounds in rats.

Administration, Oral↗

Supercritical fluid chromatography/tandem mass spectrometric method for analysis of pharmaceutical compounds in metabolic stability samples.

Packed-column supercritical fluid chromatography (pSFC) coupled to an atmospheric pressure chemical ionization (APCI) source and a tandem mass spectrometer (MS/MS) for rapid and simultaneous determination of clozapine, ondansetron, tolbutamide and primidone in in vitro samples was developed in support of metabolic stability experiments. The effects of the eluent flow-rate and composition as well as the nebulizer temperatures on the ionization efficiency of the analytes in positive ion mode under normal phase pSFC conditions were studied. The metabolic stability of the test drug components through microsomal incubation by the proposed pSFC-APCI/MS/MS approaches requiring approximately 1 min per samples were evaluated with respect to specificity, durability and accuracy. These metabolic stability results obtained by pSFC-MS/MS methods are in a good agreement with those obtained by fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method.

Animals↗

Chiral liquid chromatography-tandem mass spectrometric methods for stereoisomeric pharmaceutical determinations.

The characterization of the drug metabolism and pharmacokinetic (DMPK) profiles of stereoisomers is a fundamental aspect of the drug discovery and development processes. Therefore, chiral drug bioassays are very important to pharmaceutical and biomedical researchers. The recent developments in chiral liquid chromatography coupled to atmospheric pressure ionization tandem mass spectrometry (LC-API-MS/MS) for the analysis of pharmaceuticals are reviewed. Various ionization techniques including electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric photoionization (APPI) interfaced with chiral liquid chromatographic methods are described in terms of their ionization efficiencies, matrix effects and limitations. Examples were selected to demonstrate the applicability of these methods for enantioselective bioanalysis.

Chromatography, High Pressure Liquid↗

Comparison of atmospheric pressure chemical ionization, electrospray ionization, and atmospheric pressure photoionization for the determination of cyclosporin A in rat plasma.

Atmospheric pressure chemical ionization was compared with electrospray ionization and atmospheric pressure photoionization (APPI) as an interface of high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) for the determination of cyclosporin A (CsA) in biological fluids in support of in vivo pharmacodynamic studies. These ion sources were investigated in terms of their suitability and sensitivity for the detection of CsA. The effects of the eluent flow rate and composition as well as the nebulizer temperatures on the photoionization efficiency of CsA in the positive ion mode under normal-phase HPLC conditions were explored. The ionization mechanism in the APPI environment with and without the use of the dopant was studied using two test compounds and a few solvent systems employed for normal-phase chromatography. The test compounds were observed to be ionized mainly by proton transfer with the self-protonated solvent molecules produced through photon irradiation. Furthermore, ion suppression due to sample matrix interference in the normal-phase HPLC-APPI-MS/MS system was monitored by the postcolumn infusion technique. The applicability of these proposed HPLC-API-MS/MS approaches for the determination of CsA at low nanogram per milliliter levels in rat plasma was examined. These proposed methods were then compared with respect to specificity, linearity, detection limit, and accuracy.

Air Ionization↗

Chiral supercritical fluid chromatography/tandem mass spectrometry for the simultaneous determination of pindolol and propranolol in metabolic stability samples.

A chiral packed-column supercritical fluid chromatographic (pSFC) system coupled to tandem mass spectrometer (MS/MS) for the rapid measurements of (R,S)-propranolol and (+/-)-pindolol in metabolic stability samples was developed. The effects of the eluent flow rates and compositions, as well as of the nebulizer temperature, on the chromatographic performance and the ionization efficiency of the analytes in positive ion mode under pSFC conditions were studied. The ionization mechanism of the analytes in the CO2/methanol atmospheric pressure chemical ionization (APCI) environments with or without the use of an additive was studied. The chiral pSFC-APCI-MS/MS approach requiring approximately 2 min per sample was applied for the simultaneous determination of two pairs of racemic drugs in in vitro samples at low nanogram per milliliter concentrations.

Animals↗

Simultaneous determination of nicotinic acid and its metabolites using hydrophilic interaction chromatography with tandem mass spectrometry.

A hydrophilic interaction chromatographic (HILIC) system interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of nicotinic acid (NiAc) and its metabolites in dog plasma in support of a pharmacokinetic study. A silica column was adapted for separation of NiAc and its two metabolites, nicotinamide (NiNH2) and nicotinuric acid (NiUAc), under HILIC conditions. The influence of experimental factors such as the composition of mobile phase on ionization efficiency and chromatographic performance of all analytes was investigated. The feasibility of the proposed HILIC/MS/MS methods was explored by comparing the plasma levels of NiAc, NiNH2, and NiUAc in dog obtained by using either electrospray ionization or atmospheric pressure chemical ionization interfaces in positive ion mode. The methods were partially validated in terms of inter-day accuracy and precision, extraction recovery, benchtop and freeze/thaw stability. Further, the potential of ionization suppression resulting from endogenous components of the biological matrixes on the HILIC/API-MS/MS methods were investigated using the post-column infusion technique.

Animals↗

Stabilizing drug molecules in biological samples.

Stability is one of the basic parameters, along with accuracy, precision, selectivity, and sensitivity, for bioanalytic method validation in nonhuman and clinical pharmacology/toxicology, bioavailability (BA), bioequivalence (BE), and other studies related to the drug approval process. In the drug development stage where stability evaluation is obligatory, instability of drug candidates in biologic samples will seriously complicate assay validation. In this article, we review the general strategies and methodologies such as temperature adjustment, pH control, derivatization, and addition of inhibitors and oxidant that are commonly employed to stabilize pharmaceuticals that might be unstable in biologic samples.

Animals↗

Simultaneous fast HPLC-MS/MS analysis of drug candidates and hydroxyl metabolites in plasma.

A rapid bioanalytical method was evaluated for the simultaneous determination of drug discovery compounds and their potential metabolites in plasma samples within 1 min run time by fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS). The fast HPLC-MS/MS system is achieved by using mini-column HPLC coupled to tandem mass spectrometer which is advantageous over regular HPLC-MS/MS systems, such as a shorter chromatographic region of ionization suppression, less solvent consumption and higher throughput. Matrix ionization suppression effect of the test compounds in plasma samples when using fast HPLC-MS/MS method was examined by a post-column infusion technique. In the described example, the proposed approach has been successfully employed to determine the plasma concentration of the test compound and its hydroxyl metabolite (M+16) in monkey in the low ng/ml region. The monkey pharmacokinetic results obtained by the proposed fast HPLC-MS/MS method were in good agreement within 20% error with those obtained by the regular HPLC-MS/MS method based on the same sample preparation procedure.

Animals↗

High-performance liquid chromatography-atmospheric pressure photoionization/tandem mass spectrometric analysis for small molecules in plasma.

A generic high-performance liquid chromatography (HPLC) system interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer was developed for the quantitative determination of small molecules in plasma in support of exploratory in vivo pharmacokinetics. This report summarizes the effects of variations in reversed-phase mode HPLC conditions such as mobile-phase flow rate, solvent composition, organic modifier content, and nebulizer temperature on the photoionization efficiency of both clozapine and lonafarnib. The matrix ionization suppression effect on this method was investigated using the postcolumn infusion technique. The procedure was used to quantitate plasma levels following oral administration of 42 drug discovery compounds to rats. The pharmacokinetic results of 42 drug discovery compounds in rats evaluated by both APPI and atmospheric pressure chemical ionization interfaces were found to be well correlated.

Administration, Oral↗