PubMed Health⌕ Search

Biomedical subjects

Yusuke Abe

Publications and source records attributed to Yusuke Abe.

30 records · Page 2Linked to original sources

Visible-light-induced surface graft polymerization via camphorquinone impregnation technique.

A surface modification method that is particularly applicable to complexly shaped fabricated devices has long been awaited. In this article, we describe the visible-light-induced surface photograft polymerization technique by which an inner surface of the device is modified by visible-light irradiation through the external surface. Comphorquione, as a photoradical initiator, was impregnated on a segmented polyurethane surface by solvent soaking, followed by visible-light irradiation in the presence of monomers such as acrylamide and poly(ethylene glycol) methacrylate. The resultant surfaces were highly wettable with water, and surface chemical compositional analysis by X-ray photoelectron spectroscopy revealed that the surface was graft-polymerized with these monomers. The simple and widespread applicability of this surface modification technique to biomedical devices is discussed.

Biocompatible Materials↗

Non-linear dynamic analysis of hemodynamic parameters in an undulation type artificial heart system.

Undulation pump total artificial heart (UPTAH) is a unique total artificial heart implant (TAH) using an undulation pump that is a continuous blood flow pump. To evaluate the autonomic nerve function mediating the circulation system, we analyzed the hemodynamic parameters during animal experiments with UPTAH using the non-linear mathematical analyzing technique, including chaos and fractal theory. Adult female goats were used for the implantation of UPTAH. The natural heart was replaced with UPTAH under extra-corporal circulation. The conductance- and arterial pressure-based control method (1/R control) was applied on the 5th to 7th post-operative day as the influences of the cardiopulmonary bypass circulation were diagnosed to be terminated. Hemodynamic parameters were recorded on the data recorder, and non-linear mathematical analysis was performed. For the quantitative evaluation of the strange attractor, which was the characteristics of the deterministic chaos, the fractal dimension analysis was carried out. As a result, hemodynamic parameters fluctuated on the time axis and showed fractal characteristics, which were thought to be the characteristics of the deterministic chaos. The reconstructed attractor of the hemodynamics showed various behaviors according to changes in the situation of the goats. These results suggest that non-linear dynamical analysis might be useful in monitoring the circulatory regulatory system in artificial heart circulation.

Animals↗

Ripple reduction control of the undulation pump total artificial heart.

An undulation pump total artificial heart (UPTAH) in which the revolutions of the motor are converted to undulation motion of a disk has been developed. In an experiment, a goat using the UPTAH survived for 54 days. However, a large ripple was observed in the device's output pressure and flow waveform. In calculating the spectrum of the ripple, we found that the ripple mainly comprised 2 frequency sine waves: 1 having the same frequency as and 1 having double the frequency of the motor revolutions. To reduce the ripple, 2 sine waves, 1 having the same frequency as and 1 having double the frequency of the motor revolutions, were provided to the motor current to modulate the pulse width of the pulse width modulation controlling the motor revolutions. This ripple control method reduced the pressure ripple by 90% in a mock circulation and by 70% in animal experiments. These results revealed that the ripple generated in the UPTAH could be controlled through the use of motor control software.

Animals↗

The improved Jellyfish Valve: durability enhancement with sufficient blood compatibility.

The Jellyfish Valve is one of the most promising polymer valves for artificial hearts. The present problems to be solved are 1) how to prevent a membrane fracture and 2) how to eliminate a calcification, because both of these problems were observed in experiments with goats after 312 days and 414 days of pumping. Finite element analysis demonstrated that mechanical tensile strain induced in the membrane at valve closure was clearly consistent with the fracture location as well as calcification area in in vivo experiments. Based on this finding, a new valve seat with an additional concentric ring 14 mm in diameter and 0.5 mm in width was finally developed. The maximum strain was dramatically reduced to 52% by the design improvement. Moreover, accelerated fatigue tests demonstrated that the improved valve was 10 times more durable as compared with the original valve, which was equivalent to an in vivo duration of 8.3 years. In animal experiments, including 31 days and 46 days use in a total artificial heart (TAH), no thrombus was found despite the lack of anticoagulant or antiplatelet therapies. These results indicate that the improved Jellyfish Valve might be one of the most durable polymer valves, able to perform in artificial hearts for a long period of time.

Animals↗

Third model of the undulation pump total artificial heart.

The undulation pump is a small, continuous flow displacement type blood pump, and the undulation pump total artificial heart (UPTAH) is a unique, implantable total artificial heart based on this pump. To improve the durability of the UPTAH for investigating long-term pathophysiology with UPTAH, a third model (UPTAH3) has been developed. UPTAH3 was designed to separate the left and right undulation shafts and to be more durable. The undulation pumps were also redesigned. UPTAH3 was implemented with a diameter of 76 mm, width of 78 or 79 mm, total volume of 292 ml, and weight of 620 g. The priming volumes of the left and right pumps are 26 and 21 ml, respectively. The atrial cuffs and outflow cannulae were also redesigned for UPTAH3. The maximum output against an arterial pressure load of 100 mm Hg is about 11 L/min. The maximum pump efficiency is about 15% in the left pump and 18% in the right pump, giving a maximum total efficiency for both of about 11%. To date, UPTAH3 has been tested in 17 goats, and the longest survival period was 46 days. This third model will be useful for investigating pathophysiology with UPTAH.

Animals↗

Advance in animal experiments with the undulation pump total artificial heart: 50 and 54 day survival periods with 1/R control.

The undulation pump total artificial heart (UPTAH) is a unique, implantable, total artificial heart (TAH) that uses undulation pumps. To achieve long-term survival in animals with physiologic hemodynamic conditions, a control method based on conductance and arterial pressure was applied to UPTAH. With this control method, called 1/R control, survival periods of 50 days (No. 0016, 49.6 kg) and 54 days (No. 0030, 42.5 kg) were obtained in adult female goats. In No. 0016, 1/R control was applied to the left pump, whereas in No. 0030, it was applied to the right pump. Another pump was used for left-right balance control. The control stability was better in No. 0030 than in No. 0016. The sucking effect of the left atrium was remarkable in No. 0016, possibly because of a time delay when left-right balance control was performed with the right pump. In No. 0016, the cause of death was probably a thrombus flown from a panus in the left atrium. It is possible that the left atrial suction effect influenced the thrombus and panus formation in the left atrium. In No. 0030, the cause of death was a small rupture of the membrane in the right pump. The rupture may have been caused by excessive negative pressure inside the pump. This pressure resulted from suction of the right atrium because of an unexpected control excursion, which was probably caused by a software bug. It will be necessary to redesign the undulation pump and improve the software to achieve longer survival periods for animals with physiologic hemodynamic conditions.

Animals↗

A new approach to detection of the cavitation on mechanical heart valves.

The cavitation on the mechanical heart valves (MHVs) is thought to be a cause of the mechanical failure of the occluder; also, the free radicals that would be generated when the cavitation bubbles implode might affect the patients chemically. These cavitation effects are attributed to the bubble collapse. Therefore, it is important to detect the bubble implosion behavior to analyze the cavitation on MHVs. The cavitation bubbles induce the generation of free radicals at their implosion, and the excited hydroxyl radicals emit the faint light. Based on this fact, we have tried to observe the faint light emission from a MHV to specifically capture the implosion of the cavitation bubbles. A highly sensitive CCD (charge coupled device) camera (C2400-35 VIM camera, Hamamatsu Photonics, Hamamatsu, Japan) was adopted in this study. This camera can observe low light down to the single photon counting range, and it gives two-dimensional mapping of the light. A 20 mm Björk-Shiley valve was submerged in the water tank of 10 L deionized water with luminol as a light enhancer, and then the pressure difference of 150 mm Hg was exerted on the valve at a rate of 60 bpm with a pulse duplicator. The camera and the water tank were settled in the lightproof configuration. After 2 hours of exposure, faint light images have been obtained successfully. The light emits mostly from the edge of the occluder on the inflow side in the major orifice of the valve. Therefore the results suggest that the bubbles would implode around this region and that free radicals caused by cavitation might be produced on MHV, which has coincided with our preliminary result by an electron spin resonance spectrometry.

Biophysical Phenomena↗

A temporal and spatial analysis of cavitation on mechanical heart valves by observing faint light emission.

Cavitation on mechanical heart valves (MHVs) could cause the mechanical failure of the occluder. A simple and reliable in vitro test method to evaluate cavitation potential must be developed. The bubble implosion damages the MHV material; thus, observing the behavior of the bubble implosion is essential. According to sonoluminescence, the collapsing cavity emits faint light. Therefore, in this study, the bubble collapse was analyzed both temporally and spatially by observing faint light emission. A photon counting system has been developed using a photomultiplier tube (H7360-01, Hamamatsu Photonics, Japan). The highest time resolution of this system is 5 microsec. A quartz optical fiber bundle of 2 mm diameter can be connected to this photomultiplier tube and traversed two-dimensionally over the MHV. The closure of the MHV triggers the photon counter, and the photons through 500 beats are recorded and integrated. A 20 mm Björk-Shiley valve was submerged in a water tank containing 10 L deionized water, and the pressure difference of 120 mm Hg was exerted on the valve at a rate of 60 bpm with a pulse duplicator. Approximately 700 microsec after the valve closure, light emission was detected along the edge of the occluder on the inflow side in the major orifice. Then, approximately 1,000 microsec after the closure, light along the occluder's edge in the minor orifice was recorded as well. Compared with the analysis, using a stroboscope and a high-speed camera, faint light was emitted from the collapsing cavities. In conclusion, sonoluminescnece was successfully observed around the MHV, and the photon counting technique and the traversing mechanism of the optical fiber bundle revealed the temporal and spatial distribution of the cavity collapse on the MHV.

Biomedical Engineering↗

Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart: effects of pulsatile and nonpulsatile flow.

A new system to observe the microcirculation on the bulbar conjunctiva was developed using a digital high definition microscope to investigate the influence of the flow patterns on the microcirculation in a goat with a total artificial heart (TAH). The undulation pump TAH was implanted into the goat. When the whole body condition became stable, the flow pattern was modulated between the pulsatile and the nonpulsatile mode, and the changes in the microcirculation were observed. When the flow pattern was changed from pulsatile to nonpulsatile mode, the erythrocyte velocity in capillaries dropped from 526+/-83 to 132+/-41 microm/s and remained at a low level. The number of perfused capillaries decreased as well. Then the nonpulsatile flow mode was maintained for 20 minutes. After the flow pattern was returned to the pulsatile mode again, the erythrocyte velocity recovered to the initial level (433+/-71 microm/s). In many cases, the flow of the nonperfused capillaries in the nonpulsatile mode recovered to the initial level after the flow pattern was changed to the pulsatile mode again. The perfused capillary density in the nonpulsatile mode (19.7+/-4.1 number of capillaries/mm) was significantly lower than that in the pulsatile mode (34.7+/-6.3 number of capillaries/mm). It is thought that the basal and flow stimulated endothelium derived nitric oxide release in the microvessels decreased because of the disappearance of pulsatility and that the nitric oxide induced the constriction of arterioles after the flow pattern was changed to the nonpulsatile mode. At the same time, the baroceptors might sense the decrease in the arterial peak pressure or dp/dt, and the sympathetic nerve increases activities and induce the constriction of arterioles. Then, the erythrocyte velocity in capillaries would decrease. Because of the flow pattern further in the chronic phase, it is important to follow the change in the microcirculation.

Animals↗

Development of a novel intrafascicular nerve electrode.

Artificial organs could be controlled using autonomic neural signals, because they exhibit rapid responses to physical needs similar to those of natural organs. A nerve electrode must satisfy many requirements to measure autonomous neural signals such as a long lifetime, high signal-to-noise ratio, multichannel recording, simple installation into a nerve fascicle, and good manufacturing productivity. The purpose of our study is to propose and evaluate a novel nerve electrode that satisfies these conditions, which to date has not been developed. A novel intrafascicular nerve electrode was designed, fabricated, and evaluated on autonomic nerves. Conventional extrafascicular and intrafascicular nerve electrodes were fabricated and tested for comparison to our novel intrafascicular nerve electrode. The novel intrafascicular nerve electrode had a 3-week lifetime, whereas the conventional extrafascicular nerve electrode had a 2-week lifetime. The signal-to-noise ratio was improved from 1.6 to 2.0 compared with the conventional extrafascicular nerve electrode. The novel intrafascicular nerve electrode was easier to install into a nerve fascicle and had better manufacturing productivity than the conventional intrafascicular nerve electrode. We succeeded in demonstrating the feasibility of our novel intrafascicular nerve electrode.

Animals↗

Pathophysiologic study of goats with undulation pump total artificial heart: those that survived for more than 1 month.

The undulation pump total artificial heart is an implantable total artificial heart that is being developed at the University of Tokyo. Many advances in our system have been made by the adoption of hardware and software solutions that enabled the animals with the undulation pump total artificial hearts to survive more than 1 month. Pathophysiologic observations were performed for these goats that survived. In this article, the pathophysiologic findings are described in detail for three goats that survived for 46 (goat 9916), 54 (0030), and 63 (0107) days. The microscopic findings indicated that in goat 0107 the histologic changes in key organs occurred at the termination of the experiments. Therefore, the pathophysiologic changes in goats 9916 and 0030 were mainly investigated in this study to evaluate the chronic effect caused by our total artificial heart system. The signs of chronic ischemia and cell dystrophy were observed in both the liver and kidney. Until now, 13 goats had survived more than 1 week and 6 goats survived more than 1 month, including one that survived for 63 days, which is the longest in our experimental series. The pathophysiologic results of goats 9916 and 0030 showed that the undulation pump total artificial heart might still cause some damage to the liver and the kidney. To accomplish long-term survival with the undulation pump total artificial heart, further pathophysiologic studies are required, and the necessary modifications to the total artificial heart system will need to be made.

Animals↗

Functions for detecting malposition of transcutaneous energy transmission coils.

A transcutaneous energy transmission system (TETS) for artificial hearts and ventricular assist devices uses electrical coupling of power between external and implanted coils. If the position of coils changes relative to each other, the TETS cannot feed the required power of the implanted device. During activity or sleep, the coils may move accidentally. TETS users and the people around them have to pay attention to this because the range of the position where the required power can be fed efficiently is not wide. Therefore, we added functions for the position changes of the coils to the TETS. Regular, cautious, and irregular positions were introduced, and the ranges of them were decided upon in our experiments. The cautious position was determined by the area where the change of the relative position of the coils was relatively small. When the coils were in the cautious position, the circuit was tuned by way of changing the resonant point. This modulation could give good power efficiency in the cautious position. When the coils were in the irregular position, an alarm switch was turned on. These functions ease the restriction of the coil position and give better quality of life (QOL) than do the conventional TETS.

Biomedical Engineering↗