PubMed Health⌕ Search

Biomedical subjects

Yuuki Watanabe

Publications and source records attributed to Yuuki Watanabe.

6 recordsLinked to original sources

Body density affects stroke patterns in Baikal seals.

Buoyancy is one of the primary external forces acting on air-breathing divers and it can affect their swimming energetics. Because the body composition of marine mammals (i.e. the relative amounts of lower-density lipid and higher-density lean tissue) varies individually and seasonally, their buoyancy also fluctuates widely, and individuals would be expected to adjust their stroke patterns during dives accordingly. To test this prediction, we attached acceleration data loggers to four free-ranging Baikal seals Phoca sibirica in Lake Baikal and monitored flipper stroking activity as well as swimming speed, depth and inclination of the body axis (pitch). In addition to the logger, one seal (Individual 4) was equipped with a lead weight that was jettisoned after a predetermined time period so that we had a set of observations on the same individual with different body densities. These four data sets revealed the general diving patterns of Baikal seals and also provided direct insights into the influence of buoyancy on these patterns. Seals repeatedly performed dives of a mean duration of 7.0 min (max. 15.4 min), interrupted by a mean surface duration of 1.2 min. Dive depths were 66 m on average, but varied substantially, with a maximum depth of 324 m. The seals showed different stroke patterns among individuals; some seals stroked at lower rates during descent than ascent, while the others had higher stroke rates during descent than ascent. When the lead weight was detached from Individual 4, the seal increased its stroke rate in descent by shifting swimming mode from prolonged glides to more stroke-and-glide swimming, and decreased its stroke rate in ascent by shifting from continuous stroking to stroke-and-glide swimming. We conclude that seals adopt different stroke patterns according to their individual buoyancies. We also demonstrate that the terminal speed reached by Individual 4 during prolonged glide in descent depended on its total buoyancy and pitch, with higher speeds reached in the weighted condition and at steeper pitch. A simple physical model allowed us to estimate the body density of the seal from the speed and pitch (1,027-1,046 kg m(-3), roughly corresponding to 32-41% lipid content, for the weighted condition; 1,014-1,022 kg m(-3), 43-47% lipid content, for the unweighted condition).

Acceleration↗

Fundamental characteristics of a synthesized light source for optical coherence tomography.

We describe the fundamental characteristics of a synthesized light source (SLS) consisting of two low-coherence light sources to enhance the spatial resolution for optical coherence tomography (OCT). The axial resolution of OCT is given by half the coherence length of the light source. We fabricated a SLS with a coherence length of 2.3 microm and a side-lobe intensity of 45% with an intensity ratio of LED1:LED2 = 1:0.5 by combining two light sources, LED1, with a central wavelength of 691 nm and a spectral bandwidth of 99 nm, and LED2, with a central wavelength of 882 nm and a spectral bandwidth of 76 nm. The coherence length of 2.3 microm was 56% of the shorter coherence length in the two LEDs, which indicates that the axial resolution is 1.2 microm. The lateral resolution was measured at less than 4.4 microm by use of the phase-shift method and with a test pattern as a sample. The measured rough surfaces of a coin are illustrated and discussed.

Journal Article↗

Full-field optical coherence tomography by achromatic phase shifting with a rotating polarizer.

We demonstrate two-dimensional detection optical coherence tomography (OCT) using achromatic phase shifting with a rotating polarizer. This phase shifting, which experiences a light beam with a cyclic change in its polarization state, is, in principle, independent of wavelength. We simulated the wavelength dependence of an achromatic phase shifter using Jones calculus and found that the achromatic region exceeded 145 nm when the deviation of the phase retardation was less than +/- 0.5 degrees. Using the achromatic phase shifter and a conventional phase-shift calculation method, we obtained en face OCT images of an onion at different depths. This method is effective to enhance the quality of OCT with an ultrabroad-spectrum light source.

Equipment Design↗

Spatial pattern separation of chemicals and frequency-independent components by terahertz spectroscopic imaging.

We separated the component spatial patterns of frequency-dependent absorption in chemicals and frequency-independent components such as plastic, paper, and measurement noise in terahertz (THz) spectroscopic images, using known spectral curves. Our measurement system, which uses a widely tunable coherent THz-wave parametric oscillator source, can image at a specific frequency in the range 1-2 THz. The component patterns of chemicals can easily be extracted by use of the frequency-independent components. This method could be successfully used for nondestructive inspection for the detection of illegal drugs and devices of bioterrorism concealed, e.g., inside mail and packages.

Journal Article↗

Digital Hilbert transformation for separation measurement of thicknesses and refractive indices of layered objects by use of a wavelength-scanning heterodyne interference confocal microscope.

A wavelength-scanning heterodyne interference confocal microscope quickly accomplishes the simultaneous measurement of the thickness and the refractive index of a sample by detection of the amplitude and the phase of the interference signal during a sample scan. However, the measurement range of the optical path difference (OPD) that is obtained from the phase changes is limited by the time response of the phase-locked loop circuit in the FM demodulator. To overcome this limitation and to improve the accuracy of the separation measurement, we propose an OPD detection using digital signal processing with a Hilbert transform. The measurement range is extended approximately five times, and the resolution of the OPD is improved to 5.5 from 9 microm without the electrical noise of the FM demodulator circuit. By applying this method for simultaneous measurement of thickness and the refractive index, we can measure samples 20-30-microm thick with refractive indices between 1 and 1.5.

Journal Article↗

Geometrical tomographic imaging of refractive indices through turbid media by a wavelength-scanning heterodyne interference confocal microscope.

A wavelength-scanning heterodyne interference confocal microscope has proved to provide the tomographic image of the refractive indices of transparent and turbid media on the scale of geometrical depth when weakly reflected light with an optical power as low as of the order of 10(-14) W is used. The refractive indices of the transparent object and the turbid media were measured with accuracies of -0.5% and approximately 3%, respectively. This imaging method is advantageous for evaluating quantitative refractive indices and internal structures.

Journal Article↗