PubMed Health⌕ Search

Biomedical subjects

Yves Boone

Publications and source records attributed to Yves Boone.

8 recordsLinked to original sources

Myocardial and pulmonary effects of aqueous oxygen with acute hypoxia.

BACKGROUND: The purpose of this paper was to evaluate myocardial and pulmonary effects of aqueous oxygen (AO) delivered directly into the pulmonary circulation in acute hypoxia. METHODS: Six calves (2 months old, 68.0 +/- 2.2 kg) after general anesthesia, mechanical ventilation, and median sternotomy underwent total right heart bypass using fixed flow with continuous pressure and blood gas measurements in carotid and femoral arteries, left atrium, the coronary sinus and PA. Measurements of systemic and PA pressures and O2 saturations; myocardial O2 atrioventricular (AV) differences; and O2 extraction were made. After base line measurements, hypoxic ventilation reducing the mean arterial PO2 from 277 +/- 102 mm Hg to 47 +/- 4 mm Hg (p < 0.0005) was maintained for 30 minutes. Without changes in the hypoxic ventilation (mean arterial PO2 = 49 +/- 11 mm Hg) 3 ml/min of hyperbaric aqueous oxygen (AO = oxygen diluted in saline solution) was administered into the PA for 30 minutes. Pulmonary blood flow was maintained during the entire experiment (3.7 +/- 0.3 L/min). RESULTS: Hypoxic ventilation significantly raised (p < 0.05) the systolic (30 +/- 7 vs 21 +/- 4 mm Hg), diastolic (20 +/- 6 vs 12 +/- 3 mm Hg), and mean (23 +/- 7 vs 15 +/- 3 mm Hg) PA pressure; PA/systemic pressure ratio for systolic (0.37 +/- 0.08 vs 0.25 +/- 0.06) and mean (0.56 +/- 0.19 vs 0.29 +/- 0.11) pressures; and pulmonary vascular resistance (PVR) (5.63 +/- 1.06 vs 3.53 +/- 0.75 U). Aqueous oxygen (AO) infusion significantly reduced (p < 0.05) the values obtained with hypoxic ventilation; systolic (23 +/- 5 vs 30 +/- 7 mm Hg), diastolic (11 +/- 4 vs 20 +/- 6 mm Hg), and mean (14 +/- 3 vs 23 +/- 7 mm Hg) PA pressure; PA/systemic pressure ratio for systolic (0.25 +/- 0.05 vs 0.37 +/- 0.08) and mean pressures (0.29 +/- 0.12 vs 0.56 +/- 0.19); and PVR (3.41 +/- 1.01 vs 5.63 +/- 1.06 U). AO infusion in the pulmonary circulation did not influence the myocardial O2 atrioventricular (AV) difference or the O2 extraction. CONCLUSIONS: Infusion of hyperbaric AO solution into the PA can completely reverse the negative effects of acute hypoxia on the pulmonary circulation without affecting the myocardial metabolism.

Animals↗

Aqueous oxygen: the solution to relief hypoxic pulmonary hypertension.

OBJECTIVE: To evaluate the effects of hyperbaric oxygen solution on hypoxic pulmonary hypertension. METHODS: Eleven calves, 2-month-old, 71+/-6 kg, underwent general anaesthesia, mechanical ventilation and median sternotomy. Catheters for continuous pressure and blood gas measurements were inserted in carotid and femoral arteries, left atrium, right atrium and pulmonary artery (PA), and a flow-probe placed around the PA. After baseline measurements 30 min hypoxic ventilation reduced the mean arterial PO2 from 285+/-115 to 46+/-11 mmHg (P < 0.0001). At this point, without changes in hypoxic ventilation (mean arterial PO2 maintained at 50+/-5 mmHg), 3 ml/min of hyperbaric aqueous oxygen (AO, oxygen diluted in saline solution) was infused directly into the PA for 30 min, with continuous reading of the monitored parameters. RESULTS: Hypoxic ventilation raised significantly (P < 0.005) the values of systolic (36+/-7 vs 22+/-6 mmHg), diastolic (16+/-3 vs 9+/-4 mmHg) and mean (24+/-4 vs 14+/-4 mmHg) PA pressure, PA/systemic pressure ratio for systolic (0.47+/-0.09 vs 0.24+/-0.06) and mean (0.49+/-0.13 vs 0.23+/-0.08) pressures and Pulmonary Vascular Resistance (PVR) (6.89+/-0.87 vs 2.67+/-0.38 U), while the Pulmonary Blood Flow (PBF) decreased (2.7+/-0.4 vs 3.7+/-0.4 l/min). AO infusion reduced significantly (P < 0.005) the values obtained with hypoxic ventilation with systolic (26+/-6 vs 36+/-7 mmHg), diastolic (11+/-4 vs 16+/-3 mmHg) and mean (16+/-4 vs 24+/-4 mmHg) PA pressure, PA/systemic pressure ratio for systolic (0.27+/-0.07 vs 0.47+/-0.09) and mean (0.27+/-0.08 vs 0.49+/-0.13) pressures and PVR (3.42+/-0.31 vs 6.89+/-0.87 U), while the PBF increased (3.6+/-0.4 vs 2.7+/-0.4 l/min). CONCLUSIONS: Acute infusion of hyperbaric AO solution into the PA completely reverses the negative effects of acute hypoxia on pulmonary circulation.

Animals↗

Vascular access for cardiopulmonary bypass procedures.

Since the initiation of cardiac surgery using cardiopulmonary bypass, little progress has been made concerning the design of catheters for vascular access. However, in the last few years, research in this specialized field has established that catheter performance not only depends on size but also on the catheter's design. The catheter's drainage hole surface area correlates with its performance, i.e., flow; the ratio of the catheter's diameter to the patient's vein diameter also correlates with flow. These findings should influence the design of future models. An example is presented with the development of the Smartcanula which maximizes hole surface area and minimizes the wall thickness in order to optimize flow rate and vascular access to the patient.

Cardiopulmonary Bypass↗

A prototype paediatric venous cannula with shape change in situ.

During cardiopulmonary bypass (CPB), venous drainage may be impeded due to small vessel and cannula size or chattering, thus, blood return to the heart-lung machine is reduced. We designed a self-expandable prototype cannula, which is able to maintain the vein open and overcome this problem and analysed its performance capability. This prototype and several other cannulae were tested using an access vessel diameter of 7 mm. An in vitro circuit was set up with a 10 mm penrose latex tube simulating the patient's vein placed between the patient preload reservoir and the cannula, encasing the cannula's inlet(s). Maximum flow rate was determined for passive venous drainage (PVD) at preloads (P) of 2 and 4 mmHg. We compared these results to three classic single-stage venous cannulae: basket tip, thoracic drain and percutaneous tip. By comparing the other cannulae to the prototype, under PVD conditions and a central venous pressure (CVP) of 2 mmHg, the prototype cannula's flow rate (1.32 +/- 0.04 L/min) outperformed the basket type (the best performing comparator) (1.02 +/- 0.08 L/min) by 23% (p < 0.005). When the preload was increased to 4 mmHg under PVD conditions, the same trend was noted with the prototype cannula (1.65 +/- 0.05 L/min), outperforming the basket cannula's value (1.26 +/- 0.05 L/min) by 24% (p < 0.001). This new cannula design provides superior flow characteristics, under all test conditions, compared to the classic single-stage venous cannulae used for paediatric CPB surgery.

Blood Flow Velocity↗

An alternative to left ventricular volume reduction.

BACKGROUND: Left ventricular (LV) remodeling leading to ventricular dilatation is ultimately a maladaptative process according to the law of Laplace. To counteract the wall stress increase, a new concept of reducing the LV cavity radius by changing the LV globular shape to a bilobular one through the insertion of transventricular splints has emerged. This procedure is tested in a model of congestive heart failure. METHODS: A bovine model was used (n = 9). Following splint insertion through a sternotomy, boluses of 2 liters of crystalloid were injected. After every bolus, hemodynamic measurements were performed without and with the splints tightened to a 10% and 20% stress level reduction, respectively. Comparisons between the 3 measurements were performed with analysis of variance test (p < 0.05). RESULTS: Splint tightening significantly reduced right and left heart pressures for central venous pressure (CVP) >10 mm Hg (CVP: 14.7 +/- 5.2, 12.1 +/- 5, 10.6 +/- 4.7 mm Hg, p < 0.001 for baseline, 10% and 20% stress level reduction, respectively; mean pulmonary artery pressure: 33.5 +/- 4.7, 31 +/- 4.4, 29.4 +/- 5.1 mm Hg, p < 0.001; pulmonary capillary wedge pressure: 20.5 +/- 2.8, 18.9 +/- 3.3, 17.5 +/- 3.1 mm Hg, p < 0.001). The same holds true for cardiac output (6.5 +/- 1.6, 6.7 +/- 1.4, 6.8 +/- 1.7 liter/minute, p < 0.001), whereas heart rate and mean arterial pressure were not affected. The systemic and pulmonary resistances did not vary significantly throughout the procedure. Importantly, none of the hemodynamic parameters worsened at any stage with the splints. CONCLUSIONS: In this model, hemodynamic parameters are improved with the splints for higher values of CVP, supporting the concept of reshaping the remodeled LV. This technique has the potential to improve patients with congestive heart failure.

Animals↗

Hemocompatibility of a coaxial pump catheter for less invasive heart surgery.

Off-pump coronary artery bypass (OPCAB) requires heart manipulation during exposure of the lateral and posterior walls of the heart, which may cause hemodynamic instability, mainly through right ventricular dysfunction. A coaxial atrial cannula connected to a minicentrifugal pump was developed to bypass the right heart. This study was designed to test the hemocompatibility of this pump ongoing for 6 h. In five calves (bodyweight, 70.3+/-4.2 kg), the pump was inserted and set to its maximal motor speed of 7000 rpm. Blood samples were taken for blood gas analyses, hematology and chemistry on an hourly basis. ANOVA was used for statistical analysis. During the 6-h run, hematocrit and red blood cell count were stable (p=0.77 and 0.87, respectively). Platelet count was not significantly altered (p=0.55). LDH was stable (p=0.61) and plasma free hemoglobin remained below 100 mg/l throughout the experiment. Adequate tissue perfusion was maintained as reflected by the stable mixed venous oxygen saturation (baseline, 72.5+/-2%, and 6 h, 65.6+/-3.4%) and no defect of any pump system was detected during this 6-h testing. This right heart minipump appears to have a minimal impact on red cells and platelets when set at its maximal speed for 6 h, underlining the hematological safety of the system.

Animals↗

[Paediatric mechanical cardiac assistance].

The mechanical cardiac assistance, once limited only to the adult patients, is now progressively extended to the paediatric population, including neonates. Currently for children with cardiorespiratory insufficiency requiring for a mechanical assistance there are available several options: Intra-Aortic Balloon Pump, Extra-Corporeal Membrane Oxygenation (ECMO) et le Ventricular Assist Device. From April 1999 in our Department of Cardiovascular Surgery at CHUV 8 children, including 4 neonates, have been treated with ECMO. Indications, contra-indications, advantages, disadvantages, results and complications of the available options of paediatric mechanical cardiac assistance are described.

Child↗

In vivo testing of a right heart mini-pump during a 24 hour period: is it safe?

A coaxial atrial cannula connected to a mini-centrifugal pump was developed to bypass the right heart during extreme exposures in off-pump coronary artery bypass surgery. This study was designed to test the effect of this pump, running during 24 hours, on blood elements to evaluate its use as a prolonged right heart support. In a calf model (body weight 68+/-5 kg), the pump was inserted and set to its maximal motor speed of 7000 rpm. Blood samples were drawn every 6 hours for blood gas analyses, as well as for hematology and chemistry. The right heart mini-pump performed perfectly at its maximal speed over the 24 hour period. Blood gas parameters and blood lactate levels reflected adequate tissue perfusion (baseline: 2.2+/-0.5 mmol/L vs. 24 h: 2+/-0.3 mmol/L; p = 0.64). Red blood cell count was stable (baseline: 9.8+/-1.4 x 10(12)/L vs. 24 h: 9.6+/-1.1 x 10(12)/L; p = 0.83). Free plasma hemoglobin remained below 100 mg/L throughout the experiment. Platelet count was stable during the first 6 hours and exhibited a tendency to drop thereafter (baseline: 749+/-104 x 10(9)/L vs. 24 h: 486+/-20 x 10(9)/L; p = 0.01). This right heart mini-pump appears to provide sufficient blood flow during a 24 hour period with minimal impact on red cell and moderate platelet damage after 6 hours. These results suggest a potential application of this system for postcardiotomy right heart support.

Animals↗