Effective pig liver preservation with an extracellular-like UW solution containing the oncotic agent polyethylene glycol: a preliminary study.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Z El Rassi.
Explore the source record for details and available documents.
An on-column trace enrichment method for CEC of dilute samples is presented. The method involves on-line preconcentration by frontal electrochromatography under conditions of strong solute binding to the stationary phase followed by a step-gradient elution electrochromatography with a mobile phase of high eluting strength. This method is tested with dilute samples of carbamate insecticides using capillary columns of 100-microm i.d. packed with a 5-microm octadecyl silica (ODS) stationary phase. The effectiveness of on-line preconcentration (i.e., zone narrowing) depends on the retention factor, k', of the analyte in the injection solvent as well as in the eluting mobile phase (i.e., the organic solvent content), the applied voltage during sample introduction, and elution and length of the introduced sample plug. Under optimal frontal and elution electrochromatography conditions, a 500-fold sensitivity increase is achieved for carbofuran (a carbamate insecticide) with a UV detector. The method is demonstrated with deionized and tap water samples spiked with carbamate insecticides.
In this report, we describe the preparation of porous polyacrylamide-based monolithic columns via vinyl polymerization. These monoliths possess in their structures bonded dodecyl ligands and sulfonic acid groups. While the sulfonic acid groups are meant to support the electroosmotic flow (EOF) necessary for moving the mobile phase through the monolithic capillary, the dodecyl ligands are introduced to provide the nonpolar sites for chromatographic retention. However, incorporating the sulfonic acid groups in the monoliths does not only support the EOF but also exhibit hydrophilic interaction with moderately polar compounds such as urea herbicides and carbamates insecticides. Consequently, mixed-mode (reversed-phase/normal phase) retention behavior is observed with neutral and moderately polar pesticides. The amount of sulfonic acid group in the monolith can be conveniently adjusted by changing the amount of vinylsulfonic acid added to the polymerization reaction. Optimum EOF velocity and adequate chromatographic retention are obtained when 15% vinylsulfonic acid is added to the reaction mixture. Under these conditions, rapid separation and high plate counts reaching greater than 400000 plates/m are readily obtained.
Synthetic pesticides are important chemicals since they are widely used to control many types of weeds, insects, and other pests in a wide variety of agricultural and nonagricultural settings. This review article is aimed at describing the recent progress made in capillary electrophoresis (CE) and capillary electrochromatography (CEC) of pesticides and metabolites. The various electrophoretic systems and detection schemes that were introduced during the period extending from the second half of 1999 to the first half of 2001 for the CE and CEC of pesticides are discussed. Also included in this review article are the various approaches for trace enrichment that are involved in the analysis of dilute pesticide samples.
Anilines are important pollutants occurring in the environment as industrial discharges as well as the transformation products (i.e., metabolites) of a wide variety of commonly used pesticides. In this report, we describe the precolumn derivatization of anilines with fluorescein isothiocyanate (FITC) and their subsequent separation and detection by capillary electrophoresis-laser induced fluorescence (CE-LIF) detection. The FITC-aniline derivatives were readily detected at the 10(-10) M level. This limit of detection (LOD) was achieved in the presence of glycosidic surfactants complexed with borate at alkaline pH yielding the so-called in situ charged micelles. The glycosidic surfactants evaluated were n-octyl- and n-nonylglucopyranoside. Furthermore, and under optimum conditions, the FITC precolumn derivatization of the anilines was performed in real water (e.g., tap and lake water) spiked with anilines at the LOD level. The water matrices showed marginal effects on the extent of derivatization at the LOD level, and the possible interferents in the water samples did not affect the FITC-solute signal due to the selectivity of the derivatization and detection schemes. Besides filtration from microparticles, the real water samples did not necessitate extensive sample cleanup prior to derivatization.
In this report, we describe a surfactant-mediated electrokinetic capillary chromatography (SM-EKC) system for the separation of 9-fluoroenylmethyl chloroformate (FMOC)-derivatized anilines by capillary electrophoresis (CE). The SM-EKC system consisted of dioctyl sulfosuccinate (DOSS)/acetonitrile mixtures and was suited for the CE separation of the relatively hydrophobic FMOC-aniline analytes and other neutral compounds, e.g. alkylphenyl ketones. While the organic modifier acetonitrile (ACN) allowed the solubilization of the hydrophobic solutes and maintained the DOSS surfactant in its monomeric form by inhibiting micellization, the DOSS surfactant associated with the FMOC anilines to a varying degree thus leading to their differential migration and separation. Under these conditions, the FMOC-anilines were readily detected at the 10(-6) M level by UV at 214 nm and at the 10(-8) M level by laser-induced fluorescence (LIF) using a solid-state UV laser operating at 266 nm line as the excitation wavelength. The FMOC precolumn derivatization was also readily performed in lake water spiked with anilines at near the limit of detection (LOD) level. The lake water matrix showed no significant effects on the extent of derivatization at the LOD level as well as on the detection of the analytes due to the selectivity of the FMOC derivatization. The derivatization and detection of spiked lake water necessitated only the removal of microparticles by microfiltration prior to derivatization and detection.
In this work, the quantitation of cellular carbohydrates, namely chitin and glucan, in peanut fungal pathogens and baker's yeast was carried out by capillary electrophoresis (CE) and capillary electrochromatography (CEC). The chitin and glucan of the fungi were hydrolyzed by the enzymes chitinase and glucanase, respectively, to their corresponding sugar monomers N-acetylglucosamine (GlcNAc) and glucose (Glc). These two monosaccharides were then tagged with 6-aminoquinoline (6-AQ) to allow their separation and detection in CE and CEC. The 6-AQ derivatives of GlcNAc and Glc formed the basis for the determination by CE and CEC of chitin and glucan in peanut fungi and baker's yeast. Several parameters affecting the separation of the 6-AQ derivatives of GlcNAc and Glc, including the separation voltage and the composition of the running electrolyte, were investigated. Under the optimized separation conditions, the contents of cellular carbohydrates including N-acetylglucosamine, chitin, glucose, and glucan in some fungi, such as Sclerotinia minor, Sclerotium rolfsii, and baker's yeast, were successfully determined. The method described here allowed the assessment of genetic differences in Sclerotium rolfsii isolates from various locations.
In this investigation, capillary electrochromatography (CEC) with a novel stationary phase proved useful for the separation of neutral and acidic glycosphingolipids (GSLs). Four different gangliosides, namely G(M1a), G(D1a), G(D1b) and G(T1b), served as the acidic GSLs model solutes. The following four GSLs: galactosylceramide (GalCer), lactosylceramide (LacCer), globotriaosylceramide (Gb3Cer) and globotetraosylceramide (Gb4Cer) served as the typical neutral GSLs. The stationary phase, octadecyl sulfonated silica (ODSS), consisted of octadecyl functions bonded to a negatively charged layer containing sulfonic acid groups. Porous and non-porous ODSS stationary phases were examined. The retention behavior of the acidic and neutral GSLs was examined over a wide range of elution conditions, including the nature of the electrolyte and organic modifier and the pH of the mobile phase. The porous ODSS stationary phase yielded the separation of the four different gangliosides using a hydro-organic eluent of moderate eluent strength whereas the non-porous ODSS stationary phase permitted the separation of the four neutral GSLs with a mobile phase of relatively high eluent strength.
Several glycosidic surfactants (GSs) have been shown useful in the separation of enantiomers by capillary electrophoresis. The virtue of GSs is that they can be used as (i) neutral chiral additives in the running electrolyte for the enantioseparation of charged chiral solutes by capillary zone electrophoresis, (ii) as in situ charged micelles for the enantioseparation of neutral and charged chiral solutes by micellar electrokinetic capillary chromatography (MECC), (iii) as anionic chiral surfactants in the MECC mode upon covalently attaching negatively charged groups to their sugar head groups, and (iv) as neutral and anionic chiral surfactants mixed with achiral micelles (e.g., sodium dodecyl sulfate) for MECC of enantiomers. This review article is to provide a comprehensive description of GSs in the chiral separation of various enantiomers over a wide range of operating conditions.
A silica-based stationary phase with surface bound silylpropyl trialkylammonium functions was introduced and evaluated in the capillary electrochromatography of alkylbenzenes and pesticides. This stationary phase is referred to as octadecyldimethyl(3-trimethoxysilylpropyl) ammonium-silica (ODAS) and has quaternary amine functions that generate an anodic electroosmotic flow (EOF) and octadecyl functions that are responsible for solute retention by a reversed-phase chromatography mechanism. The ODAS stationary phase was characterized over a wide range of elution conditions in term of EOF and retention behavior of alkylbenzene homologous series. The ODAS stationary phase proved useful in the separation of pesticides as well as in the on-column preconcentration of dilute pesticide samples, thus permitting the detection of solution at 7 x 10(-7) M using a UV detector.
Three different fluorescent tags, namely 5-aminonaphthalene-1-sulfonic acid (ANSA), 7-aminonaphthalene-1,3-disulfonic acid (ANDSA), and 8-aminonaphthalene-1,3,6-trisulfonic acid (ANTS) were evaluated in the precolumn derivatization of some chiral phenoxy acid herbicides, some chiral transformation products of pyrethroid insecticides, and in their subsequent enantiomeric separation by capillary electrophoresis (CE). The electrolyte systems consisted of sodium phosphate buffers containing chiral surfactants such as octylglucoside (OG) or octylmaltoside (OM) at concentrations above the critical micellar concentration (CMC). Among the three different tags investigated, the ANDSA derivatives of the various solutes were more readily enantioseparated than the ANSA and ANTS derivatives. While the tagging with ANSA allowed the enantioseparation of a limited number of the chiral solute-ANSA derivatives investigated, the ANTS derivatization yielded derivatives that could not be enantioseparated. The polarity of the three different tags increases by increasing the number of sulfonic acid groups in the molecule in the following order: ANSA (one sulfonic acid) < ANDSA (two sulfonic acid groups) < ANTS (three sulfonic acid groups). This seems to indicate that the intermediate polarity of the ANDSA tag allowed more equitable nonpolar/polar interactions of the ANDSA-derivatized solutes with the OG or OM micelles, and consequently the enantioseparation of the solute-ANDSA derivatives. Thus, there is a solute polarity window for enantioresolution with alkylglycoside micelle by CE. Solutes of intermediate polarity that undergo more equitable nonpolar/polar interactions with the micelles exhibited chiral separations.
In this work, a commercially available diol-silica stationary phase was converted in situ to a chiral stationary phase by dynamically coating it with hydroxypropyl-beta-cyclodextrin (HP-beta-CD). This stationary phase was shown useful for the capillary electrochromatography (CEC) separation of neutral and anionic enantiomers such as some organochlorine pesticides and dansyl amino acids, respectively. The inclusion of HP-beta-CD in the mobile phase to produce the in situ chiral stationary phase allowed the rapid separation of the anionic dansyl amino acid enantiomers at relatively low electroosmotic flow (EOF). The formation of host-guest complexes between the dansyl amino acids and the neutral HP-beta-CD in the mobile phase lowered the actual charge-to-mass ratios of the anionic solutes, thus speeding up their transport by the EOF across the packed capillary column. Several parameters affecting enantioseparation were investigated, including the concentration of HP-beta-CD, ionic strength, pH, and organic modifier content of the mobile phase.
A chiral silica-based stationary phase having surface-bound hydroxypropyl-beta-cyclodextrin (HP-beta-CD) with a relatively strong electroosmotic flow (EOF) was introduced for enantioseparation by capillary electrochromatography (CEC). The stationary phase contained a hydrophilic sulfonated sublayer to which a chiral top layer of HP-beta-CD was immobilized. While the sulfonated sublayer was to provide a relatively strong EOF, the top HP-beta-CD was to confer the desired chiral recognition towards enantiomeric solutes. This HP-beta-CD sulfonated silica (CDSS) stationary phase proved useful for the rapid separation of anionic enantiomers such as dansyl amino acids and phenoxy acid herbicides. The effects of the organic modifier content, pH, and ionic strength of the mobile phase on enantioseparation were investigated. Under the optimized separation conditions, ten dansyl amino acids and six phenoxy acid herbicides were enantioseparated with a resolution greater than unity.
A selective and sensitive method for the determination of total glucosinolates (GSs) in plant extracts by capillary electrophoresis-laser-induced fluorescence (LIF) detection was developed. It was based on the enzymatically released glucose from glucosinolates in the presence of the hydrolyzing enzyme myrosinase. The released glucose was converted to gluconic acid (GA) by the action of glucose oxidase. The resulting GA was then labeled selectively with the fluorescent tag 7-aminonaphthalene-1, 3-disulfonic acid (ANDSA). The peak area resulting from the GA-ANDSA derived from free and bound glucose was subtracted from the peak area of the GA-ANDSA resulting from the free glucose in the sample. This gave the total glucosinolates in the sample. The peak areas were normalized to the internal standard, N-acetylneuraminic acid derivatized with ANDSA. The method was validated using four different plant extracts, white cabbage leaves, rapeseed leaves, rapeseed roots, and rapeseed seeds. Furthermore, a capillary electrophoresis-UV detection method for profiling GS in plant extracts was developed. In addition to providing a fingerprint of the glucosinolates in plant extracts, the method allowed the experimenter to rapidly check the various steps involved in the extraction and sample cleanup.
Capillaries consisting of two segments each packed with a different stationary phase were introduced for the control and manipulation of the electroosmotic flow (EOF) in capillary electrochromatography (CEC). This kind of column configuration was called segmented capillary where one segment was packed with octadecyl silica (ODS) and served as the separation segment while the other segment was packed with bare silica and functioned as the EOF accelerator segment. The average flow in the segmented capillary increased linearly with increasing fractional length of the EOF accelerator segment, and consequently the analysis time was reduced. Under a given set of conditions, the average flow can be varied over a certain range that extends from the EOF in the individual ODS capillary at the lower end to the EOF in the individual bare silica capillary at the higher end. The pore size of the bare silica in the EOF accelerator segment influenced the average flow in the segmented capillary. Because of the difference in the EOF of the individual segments, the average flow across the segmented capillary is partially degenerated from EOF to viscous flow. Furthermore, the retaining frits in CEC columns are restrictive points which slow down the average flow, thus furthering the degeneration of the flow from EOF to viscous flow. In other words, in CEC columns containing retaining frits, the flow of the mobile phase is not only based on electroosmosis but is contaminated by a viscous component.
An octadecyl-sulfonated silica (ODSS) stationary phase specially designed for performing capillary electrochromatography (CEC) at relatively strong electroosmotic flow (EOF) proved useful for the separations of some nucleosides and bases. The ODSS stationary phase is composed of a hydrophilic, negatively charged sublayer to which a nonpolar top layer containing octadecyl ligands is covalently attached. The charged sublayer contains sulfonic acid groups which ensure a relatively strong EOF. Due to the presence of permanently charged sulfonic acid groups in the sublayer, the hydrophilic nature of the sublayer and the hydrophobic character of the top octadecyl layer, retention and selectivity of charged and relatively polar nucleosides and bases on the ODSS stationary phase are based on electrostatic interaction, hydrophilic interaction, and reversed-phase mechanisms. This yielded for the ODSS stationary phase a unique selectivity towards the nucleosides and bases, thus allowing their rapid separation. To gain insight into the chromatographic behavior of nucleosides and bases on the ODSS stationary phase, the results were compared to those obtained on an octadecyl-silica (ODS) capillary under otherwise the same elution conditions. Due to the difference in the nature of the organic layers on the surface of the ODSS and ODS stationary phases, the elution order on both stationary phases differed significantly, and the ODSS capillary proved more suitable for the separation of the nucleosides and bases than the ODS capillary.
Capillary electrochromatography (CEC) was introduced to the separation of nine important urea herbicides using octadecyl-silica (ODS) capillary columns that were specially designed to allow the realization of a relatively strong electroosmotic flow (EOF) and, in turn, fast separations. The ODS stationary phase was intentionally prepared to have a low surface coverage in octadecyl ligands in order to ensure a strong EOF. This ODS stationary phase of low surface coverage exhibited the usual reversed-phase chromatographic behavior as was manifested by the linearity of plots of log kappa versus the percent organic modifier in the mobile phase. The nature of the organic modifier of the mobile phase influenced the order of elution as well as the separation efficiency of the nine urea herbicides. Mobile phases containing acetonitrile yielded higher separation efficiency (by a factor of 1.5) than methanol-containing mobile phases. This was attributed to the higher mass transfer resistances of the solute in and out of the pores in the presence of the more viscous methanol-containing mobile phases. Due to the relatively strong affinity of the urea herbicides to the ODS stationary phase, on-line preconcentration consisting of prolonged injections allowed the determination of 10(-5) M urea herbicide samples using a UV detector without sacrificing separation efficiency. This was further decreased to 10(-7) M when the prolonged injection was preceded by the injection of a plug of water. The plug of water (the more retentive mobile phase) brought about an enhanced accumulation of the dilute samples into a narrow band at the inlet of the CEC column. When this on-column sample enrichment approach was combined with an off-line sample preconcentration step, which consisted of a solid-phase extraction process, ultra dilute samples of 10(-10) M (0.1 ppb) could be detected.
Chiral cyclohexyl-pentyl-beta-D-maltoside (CYMAL-5) surfactant was evaluated in the enantioseparation of charged racemic species by capillary electrophoresis. CYMAL-5 is a glycosidic surfactant (GS) with a chiral maltose polar head group and a cyclohexyl-pentyl hydrophobic tail. At concentrations above its critical micellar concentration (CMC), CYMAL-5 produces neutral micelles in aqueous media. The neutral micelles migrate at the velocity of the electroosmotic flow (EOF). As expected, the CYMAL-5 system was only useful for the enantioseparation of charged chiral solutes. The enantioresolution of the CYMAL-5 can be manipulated over a wide range of electrolyte composition, e.g., pH, ionic strength and surfactant concentration. In the presence of EOF, and in all cases, there is an optimum surfactant concentration for maximum enantioresolution, which is located at low surfactant concentration for strongly hydrophobic solutes and at high surfactant concentration for relatively hydrophilic solutes. The presence of an optimum surfactant concentration for maximum enantioresolution is attributed to the EOF. At low pH values where the EOF is negligible, enantioresolution increased with increasing surfactant concentration in the useful concentration range in a way similar to chromatography.