PubMed Health⌕ Search

Biomedical subjects

Z Friedman

Publications and source records attributed to Z Friedman.

At least 19 recordsLinked to original sources

Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs.

BACKGROUND: Similarly to systolic pressure variation (SPV), pulse pressure variation (PPV) and stroke volume variation (SVV) derived from arterial pulse contour analysis have been shown to reflect fluid responsiveness in ventilated patients. However, unlike the SPV, both PPV and SVV have not been validated during extreme hypovolaemia. The aim of the present study was to examine whether these newly introduced variables respond to gradual hypovolaemia like the SPV by increasing gradually with each step of the haemorrhage even during extreme hypovolaemia. METHODS: SPV, SVV and PPV were measured in 8 dogs following initial volume loading (10% of the estimated blood volume administered as colloid solution), 5 steps of graded haemorrhage, each consisting of 10% of the estimated blood volume, followed by retransfusion of the shed blood. RESULTS: The correlations of the SVV, SPV and PPV to the stroke volume (SV) throughout the study were -0.89, -0.91 and -0.91, respectively. Correlations of the CVP and the global end-diastolic volume (GEDV) of the heart chambers to the SV were 0.79 and 0.95, respectively. The SPV correlated significantly with both the PPV and the SVV (r=0.97 and 0.93 respectively). However, the PPV increased by more than 400% at 50% haemorrhage compared with increases of 200% and 120% for the SVV and %SPV, respectively. CONCLUSION: This study demonstrates that the present algorithm used for the calculation of the SVV and the formula used to calculate the PPV, perform well over a wide range of preload states including severe hypovolaemia. However, the PPV changes more than the SPV and SVV. This may be due to the changing relation of the SV to the pulse pressure when the filling of the aorta is greatly decreased.

Algorithms↗

[Does hypothyroidism contribute to the etiology of primary open angle glaucoma or is it just a coincidence?].

In a prospective study 83 consecutive patients with progressive primary open angle glaucoma (research group) and 62 patients scheduled for cataract surgery (control group), were evaluated for the presence of hypothyroidism by history, blood levels of TSH and free T4 when necessary. In the research group, nine patients (10.8%) had hypothyroidism, 6 of them already known. In group 2 only one patient (1.6%) had known hypothyroidism, this difference was statistically significant (p < 0.005). The association between primary open glaucoma and hypothyroidism is discussed.

Cataract Extraction↗

Cardiac output assessed by arterial thermodilution during exsanguination and fluid resuscitation: experimental validation against a reference technique.

BACKGROUND AND OBJECTIVE: The arterial thermodilution technique offers the ability to measure cardiac output using only central venous and arterial catheters. However, the technique has been reported to overestimate cardiac output because of a higher loss of cold indicator due to the increased distance between the sites of injection and measurement. In this study, the two techniques were compared with respect to conditions of low cardiac output in which a longer passage time may further increase loss of indicator. METHODS: Seventeen anaesthetized dogs were studied during hypovolaemic shock and fluid resuscitation. Cardiac output measurements were carried out simultaneously by arterial and pulmonary artery thermodilution techniques. RESULTS: One-hundred-and-two measurements were performed. The mean cardiac output was 2.28 +/- 1.4Lmin(-1) by the pulmonary arterial technique and 2.29 +/- 1.56Lmin(-1) by the arterial thermodilution technique. The correlation coefficient between the two measurements was 0.95, the precision -0.04 +/- 0.41 Lmin(-1) and the limits of agreement from -0.86 to 0.78Lmin(-1). The agreement was also consistent at low cardiac outputs. CONCLUSIONS: The arterial thermodilution technique may serve as a less invasive cardiac output monitor in conditions of severe bleeding and shock.

Animals↗

Evidence for activation of the coagulation system in migraine with aura.

Migraine with aura has been shown to be an independent risk factor for stroke. Although the precise mechanism of migraine-related stroke is not known, risk factors for hypercoagulability have been found in migraineurs. Prothrombin factor 1.2 (F1.2) is a cleavage product of prothrombin. Elevated plasma F1.2 has been shown to be a sensitive and a specific marker of ongoing thrombin generation, and thus may serve as an indicator of hypercoagulability. In this study we determined plasma F1.2 levels in 35 patients with migraine (22 with aura and 13 without aura) and in 24 healthy age- and sex-matched volunteers. Elevated F1.2 levels were found in 11 of 22 (50%) patients with migraine with aura (1.25-3.5 nmol/l). None of the patients with migraine without aura nor any of the healthy volunteers had elevated plasma F1.2 levels (normal < 1.1 nmol/l). We conclude that prothrombin F1.2 levels are elevated in a significant number of patients with migraine with aura but not in patients with migraine without aura. This finding suggests that there is activation of the clotting system in certain patients with migraine with aura.

Adult↗

Macular infarction in thrombotic thrombocytopenic purpura.

PURPOSE: To report a patient with transient acute generalized thrombotic thrombocytopenic purpura (TTP) who suffered severe permanent visual loss due to retinal vascular occlusions in both eyes. METHODS: Case report. RESULTS: Severe permanent visual loss occurred in a patient with acute transient TTP. Extensive soft exudates were seen at the fundus of both eyes. Fluorescein angiography demonstrated multiple retinal vascular occlusions associated with capillary nonperfusion. CONCLUSIONS: Severe and permanent visual loss due to retinal vascular occlusions demonstrated by fluorescein angiography occurred in a patient with transient thrombotic thrombocytopenic purpura.

Adult↗

Diffuse muscular haemorrhage as presenting sign of juvenile systemic lupus erythematosus and lupus anticoagulant hypoprothrombinaemia syndrome.

Lupus anticoagulants are closely related to systemic lupus erythemathosus (SLE) and to thrombotic events. We describe a 12 year-old girl with a bilateral intramuscular haemorrhage of the gastrocnemius muscles as her main initial presentation of juvenile SLE. Laboratory work-up revealed lupus anticoagulant-hypoprothrombinaemia syndrome (LAHS) with very low levels of factor II due to autoantibodies. She showed a good initial clinical and laboratory response to prednisone therapy, however steroid dependency developed. To the best of our knowledge, this is the first case reported of juvenile SLE presenting with LAHS.

Antiphospholipid Syndrome↗

Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery.

UNLABELLED: Changes in arterial blood pressure induced by mechanical ventilation allow assessment of cardiac preload. In this study, stroke volume variation (SVV), which is the percentage change between the maximal and minimal stroke volumes (SV) divided by the average of the minimum and maximum over a floating period of 30 s, continuously displayed by the PiCCO continuous cardiac output monitor, was evaluated as a predictor of fluid responsiveness. Fifteen patients undergoing brain surgery were included. During surgery, graded volume loading was performed with each volume loading step (VLS) consisting of 100 mL of 6% hydroxyethylstarch given for 2 min. Successive responsive VLSs were performed (increase in SV > 5% after a VLS) until a change in SV of < 5 % was reached (nonresponsive). A total of 140 VLSs were performed. Responsive and nonresponsive VLSs differed in their pre-VLS values of systolic blood pressure, SV, and SVV, but not in the values of heart rate and central venous pressure. By using receiver operating characteristic analysis, the area under the curve for SVV (0.870, 95% confidence interval [CI]: 0.809 to 0.903) was statistically more than those for central venous pressure (0.493, 95% CI: 0.397 to 0.590, P = 7 x 10(-10)), heart rate (0.593, 95% CI: 0.443 to 0.635, P = 5.7 x 10(-10)), and systolic blood pressure (0.729, 95% CI: 0.645 to 0.813, P: = 4.3 x 10(-3)). An SVV value of 9.5% or more, will predict an increase in the SV of at least 5% in response to a 100-mL volume load, with a sensitivity of 79% and a specificity of 93%. IMPLICATIONS: Stroke volume variation may be used as a continuous preload variable and in combination with the continuously measured cardiac output, defining on-line the most important characteristics of cardiac function, allowing for optimal fluid management.

Aged↗

Renal multigated spectral Doppler imaging before and after captopril challenge.

RATIONALE AND OBJECTIVES: A new method of measurement, simultaneous multigated spectral Doppler imaging (MSDI), was used to quantify the hemodynamic changes in kidneys after administration of captopril. METHODS: Forty kidneys in 22 hypertensive patients were included in the study. All underwent MSDI and scintigraphy before and after administration of captopril. RESULTS: With scintigraphy used as the gold standard for diagnosing renal artery stenosis (RAS), three kidneys were found to be positive for RAS. Multigated spectral Doppler imaging detected a decrease in the resistive index after administration of captopril in all patients with RAS and correctly excluded RAS in one patient who was diagnosed as having RAS on scintigraphy. The resistive index was increased after captopril administration in normally functioning kidneys and was unchanged in kidneys with impaired function. CONCLUSIONS: With further supportive evidence, MSDI may prove to be a powerful tool for the acquisition of resistive index information and may increase the value of the resistive index as a physiological hemodynamic parameter in the evaluation of normal and abnormal conditions.

Adolescent↗

Prehospital stabilization of the cervical spine for penetrating injuries of the neck - is it necessary?

The purpose of this study was to assess the specific indications, benefits and risks associated with cervical spine stabilization during pre-hospital care of penetrating neck injuries. We retrospectively reviewed hospital charts and autopsy reports of 44 military casualties in Israel with a penetrating neck injury during a period of 4.5 years. A review of the literature was also carried out. In eight of 36 hospitalized casualties (22%) a life-threatening sign was diagnosed in the exposed neck - large or expanding haematoma, or subcutaneous emphysema. Surgical stabilization of the cervical spine was not performed for any of the casualties. It was concluded that life threatening complications due to penetrating neck injury are common and may be overlooked if the neck is covered by a stabilization device. It is extremely rare for a penetrating injury to result in an unstable cervical spine. New management guidelines concerning pre-hospital stabilization are suggested.

Braces↗

The effect of storage on the expression of platelet membrane phosphatidylserine and the subsequent impacton the coagulant function of stored platelets.

BACKGROUND: Platelet concentrates (PCs) derived from whole blood and stored under standard blood bank conditions undergo changes that are referred to as the platelet storage lesion. This study assesses the effect of PC preparation and storage on the distribution of phosphatidylserine (PS) in the platelet membrane and the effect that this distribution may have on the thrombogenic potential of stored PCs. STUDY DESIGN AND METHODS: Fresh platelets and PCs donated by healthy donors were obtained. PCs derived from platelet-rich plasma were studied on Day 1, Day 3, and Day 6 of storage under blood bank conditions. RESULTS: Platelet aggregation after exposure to the platelet agonists ADP and epinephrine singly declined progressively, but, when ADP and epinephrine in combination and collagen and thrombin in combination were used as agonists, the decline in platelet aggregation was less marked. PS expression as measured by Annexin V binding (mean and SD) was 2.02 +/- 0.93 percent in fresh platelet samples and increased to 5.39 +/- 4.2 percent on Day 1, 22. 1 +/- 7.1 percent on Day 3, and 39.5 +/- 12.1 percent on Day 6. Platelet prothrombinase activity (mean +/- SD) as measured by thrombin generation increased from 1.49 +/- 0.7 micro per mL in fresh platelet samples to 3.68 +/- 1.1 micro per mL in Day 1 platelets (p<0.001), 5.15 +/- 2.5 micro per mL in Day 3 platelets (p<0.001), and 4.65 +/- 2.48 micro per mL in Day 6 platelets (p<0. 001). CONCLUSION: These results show that PS expression increases after preparation of PCs from platelet-rich plasma and rises progressively during platelet storage under blood bank conditions. Furthermore, the greater PS expression is associated with increased platelet- dependent thrombin-generating capacity.

Blood Coagulation↗

Early screening for amblyogenic risk factors lowers the prevalence and severity of amblyopia.

PURPOSE: To evaluate the efficacy of a mass screening program for amblyopia and amblyogenic risk factors in infants. METHODS: Since 1968, children between the ages of 1 and 2(1/2) years in the city of Haifa, Israel, have been systematically screened for amblyopia and amblyogenic risk factors. The screening is performed by the Ophthalmology Department of Bnai-Zion Medical Center (formerly known as Rothchild Hospital). In 1995, we compared the prevalence and severity of amblyopia in two populations of 8-year-old children in elementary school: one group was a cohort of 808 children from the city of Haifa and its vicinity, who had been screened in infancy (between 1988 and 1990); and the second group, the control group, was a cohort of 782 children from Hadera and its vicinity, where this early screening program is not conducted. Amblyopia was defined as corrected visual acuity of < or =5/10 (20/40), or >1 line difference in corrected visual acuity between the two eyes. Referral rate, treatment rate, sensitivity, specificity, and positive predictive value and negative predictive value of the screening test in detecting factors that later resulted in the development of amblyopia were examined. RESULTS: The prevalence of amblyopia in the 8-year-old population screened in infancy was found to be 1.0% compared with 2.6% in the 8-year-old population that had not been screened in infancy (P =.0098). The prevalence of amblyopia with visual acuity of < or =5/15 (20/60) in the amblyopic eye was 0.1% in the screened population compared with 1.7% in the non-screened population (P =.00026). In the screened infant population, 3.6% were referred from the screening examination to a confirmatory examination and 2.2% were treated. The screening examination had a sensitivity of 85.7% and a specificity of 98.6% for amblyopia. The positive predictive value of the screening examination was 62.1% and the negative predictive value was 99.6%. CONCLUSIONS: The screening program for amblyopia and amblyogenic risk factors in infants, followed by appropriate treatment, is effective in significantly reducing the prevalence and severity of amblyopia in children.

Amblyopia↗

Value of prothrombin fragment 1.2 (F 1.2) in the diagnosis of stroke in young patients with antiphospholipid antibodies.

The presence in the serum of antiphospholipid antibodies (aPL) is associated with venous and arterial thrombosis. This observation has led to the search for these antibodies in young patients with ischemic neurologic syndromes. However, 1% to 5% of healthy people may be found to have circulating aPL without necessarily being at increased risk of thromboembolism. Thus, the finding of APLA in a patient with cerebral ischemia does not necessarily provide an explanation for the etiology of the clinical syndrome. The aim of this study was to determine whether the presence of aPL in young patients with stroke or transient ischemic attacks represents a possible cause of hypercoagulability as defined by ongoing thrombin formation with resultant elevation of prothrombin fragment 1.2 (F1.2) levels. This was a retrospective, case-control study involving 57 subjects. Twenty-seven patients had a recent cerebrovascular ischemic event--either TIA or a stroke. Fifteen were positive for aPL, and 12 were aPL-negative. Thirty subjects, matched for age and sex with no history of cerebrovascular disease, served as controls. Of this group, 20 were aPL-positive and 10 were aPL-negative. Causes of hypercoagulability other than aPL were excluded by laboratory testing. A positive test for aPL was repeated after a 6-week interval and two positive tests were required for a patient to be regarded as being aPL-positive. Levels of F1.2 were measured by an ELISA technique. There was a significant difference (p < 0.05) in the mean F1.2 levels between the aPL-positive group with a history of cerebrovascular disease (mean F1.2 = 2.3733) and each of the other study groups. There was no statistically significant difference between any of the other study groups. Our findings suggest that F1.2 levels are elevated in young patients with cerebrovascular syndromes who have aPL and in whom other causes of hypercoagulability and atherosclerotic vascular disease are absent. Elevated F1.2 in these patients may be a potential marker of the hypercoagulable state associated with aPL.

Adult↗

Late pigmented-membrane formation on silicone intraocular lenses after phacoemulsification with or without trabeculectomy.

PURPOSE: To determine the incidence of late inflammatory membrane formation with pigment precipitates on foldable silicone or poly(methyl methacrylate) (PMMA) intraocular lenses (IOLs) after phacoemulsification with or without simultaneous trabeculectomy and to identify probable causative factors. SETTING: Eye Department, Bnai-Zion Medical Center, and the Faculty of Medicine, the Technion, Haifa, Israel. METHODS: In this retrospective study, 155 eyes (140 patients) were divided into 4 groups by the surgery performed: Group 1, phacoemulsification combined with trabeculectomy and foldable silicone IOL implantation (12 eyes); Group 2, phacoemulsification combined with trabeculectomy and PMMA IOL implantation (15 eyes); Group 3, phacoemulsification alone with foldable silicone IOL implantation (66 eyes); Group 4, phacoemulsification alone with PMMA IOL implantation (62 eyes). Preoperative, intraoperative, and postoperative data were compared. RESULTS: Late inflammatory membranes were found on the anterior surface of 33% of the IOLs in Group 1, 3% in Group 3, and none in Groups 2 and 4. Membranes developed 3 to 4 months after surgery, were resistant to topical corticosteroid treatment and required repeated neodymium:YAG laser treatments. No correlation with preoperative, intraoperative, or postoperative factors was found. CONCLUSION: Foldable silicone IOLs may induce late postoperative inflammatory membranes with pigment precipitates, especially after combined phacoemulsification and trabeculectomy.

Aged↗

Simultaneous multigate spectral Doppler imaging of the umbilical artery and placental vessels: novel ultrasound technology.

OBJECTIVE: To establish gestational age-specific nomograms of pulsatility indices in the umbilical artery and chorionic and intraplacental vessels, using novel ultrasound technology. STUDY DESIGN: A prospective, cross-sectional study of 160 healthy singleton pregnancies between 18 and 33 weeks of gestation. MEASUREMENTS: Using simultaneous multigate spectral Doppler imaging specialized hardware and software, we measured the flow velocity waveforms of the umbilical artery, chorionic and intraplacental vessels. Computerized automatic mapping calculated the pulsatility indices in regions of interest. RESULTS: Data were adequately obtained for 160 fetuses. The pulsatility index values in the three sites measured decreased with advancing gestational age; the correlation coefficients r = -0.74, r = -0.67 and r = -0.68 for the umbilical artery, chorionic and intraplacental vessels, respectively, were found to be highly statistically significant (p < 0.0001). CONCLUSION: Simultaneous multigate spectral Doppler imaging provides simultaneous measurements of the velocity waveforms in the umbilical artery, chorionic and intraplacental vessels, and is a feasible and reproducible method of obtaining these data. The normal data presented may facilitate early detection of flow disturbances in the fetoplacental circulation.

Adult↗

Placental blood flow measured by simultaneous multigate spectral Doppler imaging in pregnancies complicated by placental vascular abnormalities.

OBJECTIVE: To evaluate the role of placental blood flow measurements by simultaneous multigate spectral Doppler imaging in pregnancies complicated by intrauterine growth restriction (IUGR), and for early detection of placental vascular abnormalities in high- and low-risk pregnancies. METHODS: To assess the sensitivity and specificity of abnormal placental blood flow in detecting IUGR, we followed 22 women whose pregnancies were complicated by IUGR at 28-34 weeks' gestation, and compared the findings with those obtained in 22 matched controls. We defined placental blood flow impedance as abnormal when 10% of placental pulsatility index (PI) measurements were greater than, or equal to, the mean umbilical artery PI (placental PI/umbilical PI > or = 1). To determine the predictive value of abnormal placental blood flow measurement for identifying developing uteroplacental insufficiency, we examined an unselected group of 100 low- and high-risk patients at 20-22 weeks' gestation. We correlated the Doppler findings with the development of pre-eclampsia, IUGR, placental abruption, oligohydramnios and the presence of persistent late decelerations during labor. RESULTS: Placental blood flow determination was more sensitive than umbilical artery blood flow in detecting abnormal umbilical-placental flow impedances as manifested by the presence of IUGR. Of the 100 mixed high- and low-risk patients examined at 20-22 weeks, 32 had abnormal placental blood flow. Of these, 19 (59.4%) subsequently developed pathologies associated with placental vascular disease. Of the 68 patients with normal placental blood flow, only six (8.8%) developed such pathologies. The sensitivity was 76% (19/25), with positive predictive value 59.4% (19/32); the specificity was 82.7% (62/75), with negative predictive value 91.2% (62/68). CONCLUSIONS: Abnormal intraplacental blood flow at 28-34 weeks' gestation is strongly associated with IUGR. In addition, it has moderate positive and negative predictive values for identifying subsequent development of uteroplacental vascular abnormalities.

Adult↗